照片为代表
Download
Eaton Moeller® series T0 Changeover switch, 20 A, rear mounting, Basic switch, 5 contact units, Contacts: 9, 90 °, Design number 8043
| Product Name |
Eaton Moeller® series T0 Changeover switch
|
| Catalog Number |
014670
|
| Product Length/Depth |
86 mm
|
| Product Height |
48 mm
|
| Product Width |
48 mm
|
| Product Weight |
0.166 kg
|
| Certifications |
CE
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
UV resistance only in connection with protective shield.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Fitted with: |
0 (off) position
Control unit |
| Pollution degree |
3
|
| Enclosure material |
Plastic
|
| Number of contact units |
5
|
| Device construction |
Intermediate mounting
|
| Electrical connection type of main circuit |
Screw connection
|
| Mounting position |
As required
|
| Mounting method |
Rear mounting
|
| Overvoltage category |
III
|
| Degree of protection |
IP56
NEMA 2 |
| Number of contacts |
9
|
| Functions |
Measuring between phase and N-neutral possible
|
| Rated operational current (Ie) at AC-21, 440 V |
20 A
|
| Switching angle |
90 °
|