Eaton Moeller® series PKZM0 Motor-protective circuit-breaker, 3p+1N/O+1N/C, Ir=16-20A, screw connection, large packaging PKZM0-20/NHI11-GVP
| Product Name |
Eaton Moeller® series PKZM0 Motor-protective circuit-breaker
|
| Catalog Number |
039432
|
| Product Length/Depth |
76 mm
|
| Product Height |
93 mm
|
| Product Width |
54 mm
|
| Product Weight |
0.336 kg
|
| Fitted with: |
Auxiliary switch
|
| Actuator type |
Turn button
|
| Adjustment range undelayed short-circuit release - max |
310 A
|
| Adjustment range undelayed short-circuit release - min |
310 A
|
| Device construction |
Built-in device fixed built-in technique
|
| Connection |
Screw terminals
|
| Electrical connection type of main circuit |
Screw connection
|
| Degree of protection |
IP20
|
| Number of poles |
Three-pole
|
| Functions |
Phase failure sensitive
|
| Overload release current setting - max |
20 A
|
| Overload release current setting - min |
16 A
|
| Rated operational voltage (Ue) - max |
690 V
|
| Rated operational voltage (Ue) - min |
690 V
|
| Rated operational power at AC-3e, 220/230 V, 50 Hz |
5.5 kW
|
| Rated operational power at AC-3e, 380/400 V, 50 Hz |
9 kW
|
| Rated uninterrupted current (Iu) |
20 A
|
| Rated short-circuit breaking capacity Icu at 400 V AC |
50 kA
|
| Rated short-circuit breaking capacity Ics at 400 V AC |
38 kA
|
| Rated short-circuit breaking capacity Icu at 440 V AC |
10 kA
|
| Rated short-circuit breaking capacity Ics at 440 V AC |
3 kA
|
| Rated short-circuit breaking capacity Icu at 500 V AC |
3 kA
|
| Rated short-circuit breaking capacity Ics at 500 V AC |
3 kA
|
| Rated short-circuit breaking capacity Icu at 690 V AC |
3 kA
|
| Rated short-circuit breaking capacity Ics at 690 V AC |
1 kA
|
| Short-circuit current rating (group protection) |
10 kA, 600 V High Fault, Fuse, SCCR (UL/CSA) with 150 A, 600 V High Fault, Fuse, SCCR (UL/CSA)
10 kA, 600 V High Fault, CB, SCCR (UL/CSA) with 125 A, 600 V High Fault, CB, SCCR (UL/CSA) 18 kA, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, Fuse with CL, SCCR (UL/CSA) 18 kA, 600 V High Fault, CB with CL, SCCR (UL/CSA) with 600 A, 600 V High Fault, CB with CL, SCCR (UL/CSA) 18 kA, 480 V High Fault, CB, SCCR (UL/CSA) with 600 A, 480 V High Fault, CB, SCCR (UL/CSA) 18 kA, 480 V High Fault, Fuse, SCCR (UL/CSA) with 600 A, 480 V High Fault, Fuse, SCCR (UL/CSA) |
| Short-circuit current rating (type E) |
18 kA, 240 V, SCCR (UL/CSA) with contactor DILM25
18 kA, 480 Y/277 V, SCCR (UL/CSA) with contactor DILM25 |
| Switch off technique |
Thermomagnetic
|
| Power loss |
5.82 W
|