Product Name |
Eaton Moeller® series amplifier module
|
Catalog Number |
083094
|
Product Length/Depth |
103 mm
|
Product Height |
83 mm
|
Product Width |
23 mm
|
Product Weight |
0.1 kg
|
Certifications |
CSA Class No.: 2411-03, 3211-04
CSA file No. 012528 IEC/EN 60947-4-1 UL 508 CSA-C22.2 No. 14-05 CE marking IEC/EN 60947 VDE 0660 UL CSA UL Category Control No.: NKCR UL File No.: E29184 UL Listed CSA certified |
Catalog Notes |
Contactor coils with rated operational current > 2 A must be actuated via the DILER-G mini contactor relay.
|
Used with |
DILM
DILMP DILL DILK DILMF |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
LED indication
|
Pollution degree |
2
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
|
Rated impulse withstand voltage (Uimp) |
6 kV
|
Accessory/spare part type |
Other
|
Screwdriver size |
0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
|
Voltage type |
DC
|
Degree of protection |
IP20
|
Mounting position |
As required
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient operating temperature (enclosed) - max |
45 °C
|
Ambient operating temperature (enclosed) - min |
-25 °C
|
Conventional thermal current Ith of auxiliary contacts (1-pole, open) |
6 A
|
Rated actuating current (Ic) |
25 mA
|
Coil voltage |
24 VDC
|
Overvoltage category |
III
|
Control circuit reliability |
λ < 1/10⁸ (1 failure at 100,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
|
Duty factor |
100 %
|
Terminal capacity |
1 x (0.75 - 2.5) mm², solid
2 x (0.75 - 2.5) mm², solid 1 x (0.75 - 2.5) mm², flexible with ferrule 16 - 14 AWG, solid or stranded Only use equal cross-sections. |
Mounting method |
DIN rail
|
Screw size |
M3.5, Terminal screw
|
Lifespan |
30,000,000 mechanical Operations (DC operated)
|
Rated operational current (Ie) |
2 A
|
Shock resistance |
10 g, N/O contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
|
Tightening torque |
1.2 Nm, Screw terminals
|
Rated insulation voltage (Ui) |
400 VAC
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
2 A
|
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V |
2 A
|
Rated operational current (Ie) at DC-13, 220 V, 230 V |
0.03 A
|
Rated operational voltage (Ue) at AC - max |
400 V
|
Static heat dissipation, non-current-dependent Pvs |
0.6 W
|