Eaton Moeller® series MSC-R Reversing starter, 380 V 400 V 415 V: 0.25 kW, Ir= 0.63 - 1 A, 24 V DC, DC voltage MSC-R-1-M7(24VDC)/BBA
Product Name |
Eaton Moeller® series MSC-R Reversing starter
|
Catalog Number |
103000
|
Product Length/Depth |
200 mm
|
Product Height |
153 mm
|
Product Width |
90 mm
|
Product Weight |
1.63 kg
|
Certifications |
CSA-C22.2 No. 14 (on request)
UL File No.: E123500 CE UL 508 (on request) CSA Class No.: 3211-04 IEC/EN 60947-4-1 CSA-C22.2 No. 14-10 UL60947-4-1A UL Category Control No.: NKJH CSA UL CSA File No.: 012528 |
Type |
Starter with Bi-Metal release
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Short-circuit release
|
Pollution degree |
3
|
Class |
CLASS 10 A
|
Connection to SmartWire-DT |
No
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Model |
IEC/UL starter
|
Altitude |
Max. 2000 m
|
Electrical connection type of main circuit |
Screw connection
|
Voltage type |
DC
|
Mounting method |
Mounting on Busbar 60 mm
|
Overvoltage category |
III
|
Connection |
Screw terminals
|
Functions |
Temperature compensated overload protection
|
Overload release current setting - min |
0.63 A
|
Power consumption (sealing) at DC |
3 W
|
Rated conditional short-circuit current (Iq), type 2, 230 V |
50000 A
|
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V |
50000 A
|
Rated conditional short-circuit current, type 1, 480 Y/277 V |
0 A
|
Rated conditional short-circuit current, type 1, 600 Y/347 V |
0 A
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
1 A
|
Switching capacity (auxiliary contacts, general use) |
1 A, 250 V DC, (UL/CSA)
15 A, 600 V AC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) |
A600, AC operated (UL/CSA)
P300, DC operated (UL/CSA) |
Rated operational current (Ie) |
0.8 A
|
Rated operational current for specified heat dissipation (In) |
1 A
|
Rated operational voltage |
230 - 415 V AC
|
Suitable for |
Also motors with efficiency class IE3
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-25 °C
|
Coordination type |
2
|
Equipment heat dissipation, current-dependent Pvid |
5.7 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
1.9 W
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Number of command positions |
0
|
Number of pilot lights |
0
|
Overload release current setting - max |
1 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
0.12 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
0.25 kW
|
Rated power at 460 V, 60 Hz, 3-phase |
0 kW
|
Rated power at 575 V, 60 Hz, 3-phase |
0 kW
|
Short-circuit release (Irm) - max |
15.5 A
|
Static heat dissipation, non-current-dependent Pvs |
2.6 W
|
Coordination class (IEC 60947-4-3) |
Class 2
|
Degree of protection |
IP20
NEMA Other |
Electrical connection type for auxiliary- and control-current circuit |
Screw connection
|
Actuating voltage |
24 V DC
|
Power consumption |
2.6 W
|