Eaton Moeller series Power Defense - Molded Case Circuit Breaker. Switch-disconnector, 3 p, 800A, frame size 4
Product Name |
Eaton Moeller series Power Defense molded case switch-disconnector
|
Catalog Number |
112012
|
Product Length/Depth |
401 mm
|
Product Height |
207 mm
|
Product Width |
210 mm
|
Product Weight |
17 kg
|
Compliances |
RoHS conform
|
Certifications |
IEC
|
Amperage Rating |
800 A
|
Voltage rating |
690 V - 690 V
|
Circuit breaker frame type |
LN4
|
Features |
Version as main switch
Motor drive optional Version as emergency stop installation Version as maintenance-/service switch |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Pollution degree |
3
|
Mounting Method |
Built-in device fixed built-in technique
Intermediate mounting Ground mounting Fixed Distribution board installation |
Equipment heat dissipation, current-dependent |
71.04 W
|
Rated short-time withstand current (Icw) |
25 kA
|
Electrical connection type of main circuit |
Bolt connection
|
Number of auxiliary contacts (change-over contacts) |
0
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Rated insulation voltage (Ui) |
1000 V
|
Rated operating frequency |
50 Hz
|
Rated operating power at AC-23, 400 V |
450 kW
|
Rated operating power at AC-3, 400 V |
0 kW
|
Switch positions |
I, +, 0
|
Lifespan, mechanical |
10000 operations
|
Overvoltage category |
III
|
Rated operational current |
1600 A (690 V AC-1, making and breaking capacity)
1600 A (690 V AC-22/23A, making and breaking capacity) 1600 A (415 V AC-1, making and breaking capacity) 1600 A (415 V AC-22/23A, making and breaking capacity) |
Degree of protection (IP), front side |
IP20
|
Number of poles |
Three-pole
|
Terminal capacity (copper strip) |
10 segments of 80 mm x 1 mm (2x) at rear-side width extension
Max. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched) Min. 10 segments of 50 mm x 1 mm (2x) at rear-side connection (punched) 10 segments of 50 mm x 1 mm (2x) at 1-hole module plate Max. 10 segments of 32 mm x 1 mm (2x) at flat conductor terminal Min. 6 segments of 16 mm x 0.8 mm at flat conductor terminal |
Handle color |
Gray
|
Lifespan, electrical |
2000 operations at 415 V AC-3
3000 operations at 415 V AC-1 1000 operations at 690 V AC-3 3000 operations at 400 V AC-1 2000 operations at 690 V AC-1 2000 operations at 400 V AC-3 |
Functions |
Disconnectors/main switches
Interlockable Voltage release optional |
Type |
Switch-disconnector
|
Special features |
Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.
Isolating characteristics to IEC/EN 60947-3 and VDE 0660.
Busbar tag shroud to VDE 0160 Part 100.
Rated current = rated uninterrupted current: 800 A
|
Application |
Use in unearthed supply systems at 525 V
|
Rated conditional short-circuit current (Iq) |
100 kA
|
Rated conditional short-circuit current with back-up fuse |
100 kA at 400/415 V
N4-630…1600: 2 x 800 AgGgL 80 kA at 690 V |
Rated conditional short-circuit current with downstream fuse |
100 kA at 400/415 V
N4-630…1600: 2 x 800 AgGgL 80 kA at 690 V |
Short-circuit total breaktime |
< 10 ms
|
Rated operating voltage (Ue) at AC - max |
400 V
|
Rated operational current for specified heat dissipation (In) |
800 A
|
Rated permanent current at AC-21, 400 V |
0 A
|
Rated short-time withstand current (t = 0.3 s) |
25 kA
|
Rated short-time withstand current (t = 1 s) |
25 kA
|
Switching power at 400 V |
0 kW
|
Handle type |
Rocker lever
|
Number of operations per hour - max |
60
|
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
53 kA
|
Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
Standard terminals |
Screw terminal
|
Terminal capacity (control cable) |
0.75 mm² - 2.5 mm² (1x)
0.75 mm² - 1.5 mm² (2x) |
Short-circuit protective device fuses - max |
1600 A gL
|
Terminal capacity (copper busbar) |
Max. 50 mm x 10 mm (2x) direct at switch rear-side connection
Max. 80 mm x 10 mm (2x) at rear-side width extension Min. 25 mm x 5 mm direct at switch rear-side connection Max. 80 mm x 10 mm (2x) direct at switch rear-side connection 50 mm x 10 mm (2x) at rear-side 2-hole module plate M10 at rear-side screw connection Min. 25 mm x 5 mm at rear-side 1-hole module plate Min. 60 mm x 10 mm at rear-side width extension Max. 50 mm x 10 mm (2x) at rear-side 1-hole module plate |
Terminal capacity (copper solid conductor/cable) |
35 mm² - 185 mm² (4x) at rear-side 2-hole module plate
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal 300 mm² (4x) at rear-side width extension 95 mm² - 185 mm² (2x) at rear-side 2-hole module plate 120 mm² - 300 mm² (1x) at rear-side 1-hole module plate 95 mm² - 240 mm² (6x) at rear-side width extension 95 mm² - 300 mm² (2x) at rear-side 1-hole module plate |
Terminal capacity (copper stranded conductor/cable) |
120 mm² - 185 mm² (1x) direct at switch rear-side connection
50 mm² - 185 mm² (4x) direct at switch rear-side connection |
Terminal capacity (aluminum stranded conductor/cable) |
50 mm² - 240 mm² (4x) at 4-hole tunnel terminal
|