Eaton xEffect SASY 60i Enclosures Switch- & Controlgear Enclosure. Bus-mounted switch-disconnector with fuses, 63A, 400 V, 3p, D02
| Product Name | 
                                                Eaton xEffect SASY 60i busbar system device D02
                                             | 
| Catalog Number | 
                                                114316
                                             | 
| Product Length/Depth | 
                                                226 mm
                                             | 
| Product Height | 
                                                102 mm
                                             | 
| Product Width | 
                                                27 mm
                                             | 
| Product Weight | 
                                                0.361 kg
                                             | 
| Compliances | 
                                                RoHS conform
                                             | 
| Certifications | 
                                                IEC/EN 60947-3
                                             | 
| Used with | 
                                                12 mm x 5/10 mm rail  20 mm x 5/10 mm rail 25 mm x 5/10 mm rail Double T profile 30 mm x 5/10 mm rail 15 mm x 5/10 mm rail 60 mm system 185 mm system | 
| Amperage Rating | 
                                                63 A
                                             | 
| Frame | 
                                                E18, D02, C10x38
                                             | 
| Frequency rating | 
                                                40 Hz - 60 Hz
                                             | 
| Pollution degree | 
                                                3
                                             | 
| Utilization category | 
                                                AC-22 B
                                             | 
| Climatic proofing | 
                                                Damp heat, constant, to IEC 60068-2-78  Damp heat, cyclic, to IEC 60068-2-30 | 
| Rated operational voltage (Ue) - max | 
                                                400 V
                                             | 
| Terminals | 
                                                Lift terminals
                                             | 
| Number of poles | 
                                                Three-pole
                                             | 
| Rated impulse withstand voltage (Uimp) | 
                                                6 kV
                                             | 
| Degree of protection | 
                                                IP20 enclosed
                                             | 
| Distance between busbar centers | 
                                                60 mm
                                             | 
| Ambient operating temperature - max | 
                                                55 °C
                                             | 
| Ambient operating temperature - min | 
                                                -25 °C
                                             | 
| Conventional thermal current Ith of auxiliary contacts (1-pole, open) | 
                                                63 A
                                             | 
| Current heat loss per contact at Ie | 
                                                1.5 W
                                             | 
| Enclosure width | 
                                                226 mm
                                             | 
| Heat dissipation per contact with fuse link at Ie | 
                                                7 W
                                             | 
| Construction size | 
                                                D02
                                             | 
| Mounting position | 
                                                Vertical or horizontal
                                             | 
| Functions | 
                                                Busbar fuse material  D fuse switch-disconnector with flashing function Uninterrupted operation (Control mode) | 
| Overvoltage category | 
                                                IV
                                             | 
| Frequency rating of contacts | 
                                                40 Hz - 60 Hz
                                             | 
| Mounting method | 
                                                Busbar with 60 mm clearance
                                             | 
| Rated operation current (Ie) | 
                                                63 A
                                             | 
| Voltage rating | 
                                                400 V AC
                                             | 
| Type | 
 | 
| Special features | 
 | 
| Thread type | 
                                                E18
                                             | 
| Mounting width | 
                                                27 mm per pole (1.5 space units)
                                             | 
| Terminal capacity (solid cable) | 
                                                1.5 mm² - 35 mm² at box terminal
                                             | 
| Permitted heat loss from fuse links - max | 
                                                5.5 W
                                             | 
| Rated conditional short-circuit current tested with links | 
                                                63 kA
                                             |