Product Name |
Eaton EU4A Accessory Relay expansion module
|
Catalog Number |
115735
|
Product Length/Depth |
220 mm
|
Product Height |
25 mm
|
Product Width |
160 mm
|
Product Weight |
0.06 kg
|
Compliances |
CE
|
Used with |
XC200
XC100 XC121 |
Accessories |
Programming accessories
|
Number of poles |
Five-pole
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Conductor category |
Class 2 = stranded
|
Cable category |
Other
|
Reaction-to-fire class (EN 13501-6) |
None
|
Specification material outer sheath |
Other
|
Stranding |
Other
|
Stranding element |
No
|
Ambient operating temperature - max |
45 °C
|
Ambient operating temperature - min |
-20 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Nominal cross section (conductor) |
0.5 mm²
|
Number of cores |
4
|
Number of stranding elements |
0
|
NVP value |
66.5 %
|
Permitted bending radius, moving application with forced guidance - min |
0 mm
|
Permitted bending radius, moving application with free movement - min |
0 mm
|
Permitted temperature of outer cable (assembling/handling) - max |
70 °C
|
Permitted temperature of outer cable (assembling/handling) - min |
-25 °C
|
Circuit integrity |
None
|
Approved type of underground installation |
Other
|
Material reinforcement |
Other
|
Armouring/reinforcement |
None
|
Cable geometry |
Round
|
Conductor material |
Other
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|
Product category |
SmartWire-DT accessories
|
Conductor diameter |
1.5 mm
|
AWG-size |
20
|
Cable length |
1.5 m
2 m |
Conductor surface |
Bare
|
Core identification |
Colour
|
Core insulation material |
Other
|
Suitable for |
Output card PLC
Digital signals Analogue signals Input board PLC |
Euro class acidity (EN 13501-6) |
None
|
Euro class flaming droplets/particles (EN 13501-6) |
None
|
Flame retardant |
In accordance with EN 60332-1-2
|
Electrical connection type (box-sided) |
RJ-plug
|
Electrical connection type (field-sided) |
Connection plug board
|
Outer sheath material |
Polyvinyl chloride (PVC)
|
Protective sheath material |
Other
|
Screen over stranding |
None
|
Screen over stranding element |
None
|
Smoke development class (EN 13501-6) |
None
|
Functions |
PLC - PC