Product Name |
Eaton EU5C Accessory Power supply
|
Catalog Number |
116309
|
Product Length/Depth |
125 mm
|
Product Height |
90 mm
|
Product Width |
35 mm
|
Product Weight |
0.109 kg
|
Certifications |
UL Category Control No.: NKCR
IEC/EN 61131-2 CSA CSA File No.: 2324643 UL UL File No.: E29184 CSA Class No.: 3211-07 EN 50178 |
Catalog Notes |
SmartWire-DT power supply for additionally feeding the control voltage for motor starters and contactors, as well as for establishing emergency stop groups
|
Suitable as |
Segment module
|
Features |
Fieldbus connection over separate bus coupler possible
|
Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Flat plug-in connection
|
Fitted with: |
Power supply module
|
Pollution degree |
2
|
Connection |
2 x SmartWire-DT blade terminal SWD4-8MF2
|
Burst impulse |
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3
1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3 |
Climatic proofing |
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3 |
Connection to SmartWire-DT |
Yes
|
Air pressure |
795 - 1080 hPa (operation)
|
Explosion safety category for dust |
None
|
Environmental conditions |
Condensation: prevent with appropriate measures
|
Explosion safety category for gas |
None
|
Mounting method |
Rail mounting possible
Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Wall mounting/direct mounting |
Voltage type |
DC
|
Mounting position |
As required
|
Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
Overvoltage category |
II
|
Safety performance level (EN ISO 13849-1) |
None
|
SIL (IEC 61508) |
None
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
Number of HW-interfaces (industrial ethernet) |
0
|
Number of HW-interfaces (other) |
1
|
Number of HW-interfaces (parallel) |
0
|
Number of HW-interfaces (RS-232) |
0
|
Number of HW-interfaces (RS-422) |
0
|
Number of HW-interfaces (RS-485) |
0
|
Number of HW-interfaces (serial TTY) |
0
|
Number of HW-interfaces (USB) |
0
|
Number of HW-interfaces (wireless) |
0
|
Number of interfaces (PROFINET) |
0
|
Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
Surge rating |
0.5 kV, Supply cables/CAN/DP bus cable, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
|
Electromagnetic fields |
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008)
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008) 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008) |
Protection against polarity reversal |
Yes
Yes, for supply voltage (Siemens MPI optional) |
Connection type |
SWD: 2 x plug, 8-pole
Push in terminals, Supply voltage |
Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
Radio interference class |
Class A (EN 55011)
|
Relative humidity |
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
Degree of protection |
IP20
|
Protocol |
Other bus systems
|
Residual ripple |
≤ 5 % (input voltage)
|
Rated control supply voltage |
24 V DC (UAUX, -15 %/+20 %)
|
Functions |
For feeding control voltage in order to connect additional motor starters and contactors to the SmartWire-DT ribbon cable
For the formation of emergency switching off groups for motor starters and contactors |
Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
Supply current |
3 A, Imax, Supply voltage UAux
|
System accessory |
Yes
|
Operating temperature - max |
55 °C
|
Operating temperature - min |
-25 °C
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Static heat dissipation, non-current-dependent Pvs |
1 W
|
Supply voltage at AC, 50 Hz - max |
0 VAC
|
Supply voltage at AC, 50 Hz - min |
0 VAC
|
Supply voltage at AC, 60 Hz - max |
0 VAC
|
Supply voltage at AC, 60 Hz - min |
0 VAC
|
Supply voltage at DC - max |
28.8 VDC
|
Supply voltage at DC - min |
20.4 VDC
|
Product category |
SmartWire-DT accessories
|
Potential isolation |
Supply voltage UAUX: no
|
Power loss |
Normally 1 W
|
Rated operational voltage |
Typically UAUX -0.2 V (for 24 V DC slaves)
|
Short-circuit protection |
No, external fuse FAZ Z3, Supply voltage UAux
|
Terminal capacity |
0.2 - 1.5 mm², solid
24 - 16 AWG, solid or stranded 0.25 - 1.5 mm², flexible with ferrule |