Eaton Moeller® series PKE Trip block, 30 - 65 A, System protection, Connection to SmartWire-DT: yes, For use with: PKE65 basic device
| Product Name |
Eaton Moeller® series PKE Trip block
|
| Catalog Number |
168799
|
| Product Length/Depth |
84.4 mm
|
| Product Height |
69.9 mm
|
| Product Width |
55 mm
|
| Product Weight |
0.238 kg
|
| Certifications |
IEC/EN 60947
VDE 0660 |
| Catalog Notes |
This is a product for Environment A (Industrial). In environment B (household) this device may cause undesirable radio interference. In this case the user may be obliged to take appropriate measures.
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Operating frequency |
60 Operations/h
|
| Pollution degree |
3
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30 |
| Connection to SmartWire-DT |
Yes
In conjunction with PKE-SWD-SP SmartWire DT PKE module |
| Rated operational voltage (Ue) at AC - max |
690 V
|
| Rated uninterrupted current (Iu) |
65 A
|
| Static heat dissipation, non-current-dependent Pvs |
0 W
|
| Undelayed short-circuit release - max |
520 A
|
| Undelayed short-circuit release - min |
150 A
|
| Product category |
Accessories
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| Number of poles |
Three-pole
|
| Rated impulse withstand voltage (Uimp) |
6000 V AC
|
| Functions |
Line and cable protection
System protection Overcurrent protection Short-circuit protection |
| Altitude |
Max. 2000 m
|
| Voltage type |
Self powered
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient operating temperature (enclosed) - max |
40 °C
|
| Ambient operating temperature (enclosed) - min |
-25 °C
|
| Ambient storage temperature - max |
80 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Equipment heat dissipation, current-dependent Pvid |
9.3 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
3.1 W
|
| Overload release current setting - max |
65 A
|
| Overload release current setting - min |
30 A
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
| Rated control supply voltage (Us) at DC - max |
0 V
|
| Rated control supply voltage (Us) at DC - min |
0 V
|
| Rated frequency - max |
60 Hz
|
| Rated frequency - min |
50 Hz
|
| Rated operational current for specified heat dissipation (In) |
65 A
|
| Current flow times - min |
700 (Class 10) AC-4 cycle operation, Main conducting paths
1000 (Class 20) AC-4 cycle operation, Main conducting paths Note: Going below the minimum current flow time can cause overheating of the load (motor). 900 (Class 15) AC-4 cycle operation, Main conducting paths For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. 500 (Class 5) AC-4 cycle operation, Main conducting paths |
| Degree of protection |
Terminals: IP00
Device: IP20 |
| Overvoltage category |
III
|
| Cut-out periods - min |
≤ 500 ms, main conducting paths, AC-4 cycle operation
|
| Shock resistance |
15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
|
| Protection type |
Electronic release
|
| Rated operational current (Ie) |
65 A
|
| Short-circuit release |
Delayed approx. 60 ms, Trip blocks
Trip block adjustable 5 - 8 x Ir 150 - 520 A, Irm, Setting range ± 20% tolerance, Trip blocks |
| Short-circuit release function |
Delayed
|
| Temperature compensation |
-5 - 40 °C to IEC/EN 60947, VDE 0660
-25 - 55 °C, Operating range |
| Number of auxiliary contacts (normally open contacts) |
0
|
| Number of auxiliary contacts (normally closed contacts) |
0
|
| Voltage type of supply voltage |
AC
|
| Number of auxiliary contacts (change-over contacts) |
0
|
| Voltage type of operating voltage |
AC
|
| Rated switch current |
65 A
|
| Supply voltage at AC, 50 Hz - min |
690 V
|
| Supply voltage at AC, 50 Hz - max |
690 V
|
| Supply voltage at AC, 60 Hz - min |
690 V
|
| Supply voltage at AC, 60 Hz - max |
690 V
|
| Operating voltage at AC, 50 Hz - min |
690 V
|
| Operating voltage at AC, 50 Hz - max |
690 V
|
| Operating voltage at AC, 60 Hz - min |
690 V
|
| Operating voltage at AC, 60 Hz - max |
690 V
|
| Operating voltage at DC - min |
690 V
|
| Operating voltage at DC - max |
690 V
|