Eaton S811 Soft starter, 135 A, 200 - 600 V AC, Us= 24 V DC, with control unit, Frame size R
Product Name |
Eaton S811 Soft starter
|
Catalog Number |
168982
|
Product Length/Depth |
168.6 mm
|
Product Height |
201.2 mm
|
Product Width |
111.3 mm
|
Product Weight |
4.8 kg
|
Certifications |
UL 508
CE CSA22.2-14-1995 UL CSA CSA-C22.2 No. 14 UL Category Control No.: NMFT CSA Class No.: 3211-06, 2411-01 CSA File No.: LR 353 GB14048 IEC/EN 60947-4-2 UL File No.: E202571 CCC C-Tick |
Type |
Soft starter for three-phase loads, with control unit
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Internal bypass
Display Internal bypass contacts Motor overload protection |
Pollution degree |
3
|
Class |
Adjustable
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Damp heat, cyclic, to IEC 60068-2-30 |
Connection to SmartWire-DT |
No
|
Rated impulse withstand voltage (Uimp) |
4000 V
|
Frame size |
R
|
Altitude |
Max. 2000 m
Above 2000 m with 0.5 % derating per 100 m |
Number of inputs |
1 (current input)
|
Ambient operating temperature - max |
50 °C
|
Ambient operating temperature - min |
-30 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-50 °C
|
Assigned motor power at 200/208 V, 60 Hz, 3-phase |
40 HP
|
Assigned motor power at 220/230 V, 60 Hz, 3-phase |
50 HP
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
100 HP
|
Assigned motor power at 600 V, 60 Hz, 3-phase |
125 HP
|
Assigned motor power in-delta at 220/230 V, 60 Hz |
75 HP
|
Assigned motor power in-delta at 460/480 V, 60 Hz |
150 HP
|
Assigned motor power in-delta at 575/600 V, 60 Hz |
200 HP
|
Equipment heat dissipation, current-dependent Pvid |
25 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Mains voltage - max |
600 V
|
Mains voltage - min |
200 V
|
Output voltage |
120 V AC/DC (relay outputs)
|
Number of outputs |
2 Relay Outputs (programmable)
|
Screwdriver size |
0.6 x 3.5 mm, Terminal screws, Control circuit cables
4 mm Hexagon socket-head screw, Terminal screw, Main cables |
Voltage type |
DC
|
Rated operational voltage (Ue) - min |
200 V
|
Rated power three-phase motor, inline, at 230 V |
37 kW
|
Rated power three-phase motor, inline, at 400 V |
75 kW
|
Rated power three-phase motor, inside delta, at 230 V |
75 kW
|
Rated power three-phase motor, inside delta, at 400 V |
132 kW
|
Static heat dissipation, non-current-dependent Pvs |
25 W
|
Voltage rating - max |
600 V
|
Application |
|
Protection |
Finger and back-of-hand proof, Protection against direct contact
|
Mounting position |
As required
|
Input current |
4 - 20 mA (Analog inputs)
|
Drop-out voltage |
0 - 3 V, DC operated
|
Overvoltage category |
II
|
Degree of protection |
IP00
NEMA Other |
Current consumption |
10 A/150 ms, Control circuit, Regulator supply at peak performance (close bypass) at 24 V DC
150 mA, Control circuit, Digital inputs, External 24 V 1000 mA, Control circuit, Regulator supply 100 mA, Control circuit, Digital inputs, External 24 V (no-load) |
Functions |
Min. ramp time 1 s - fast switching (semiconductor contactor)
Suppression of DC components for motors Potential isolation between power and control sections Soft start function Current limitation Single direction Suppression of closing transients Overload monitoring Underload monitoring |
Delay time |
0 - 60 s, Soft start function, Ramp times
|
Overload cycle |
AC-53a: 4.0 - 32: 99 - 3
|
Drop-out time |
100 ms, DC operated
|
Pick-up voltage |
21.6 - 26.4 V DC
|
Radio interference class |
Class A (EN 55011)
|
Fault memory |
10 Faults
|
Pick-up time |
100 ms at DC
|
Interfaces |
Modbus RTU (built-in)
|
Kickstart |
Max. 2000 ms (Kickstart Duration)
100% (Kickstart voltage) |
Rated control voltage (Uc) |
24 V DC (-10 %/+10 %)
24 V DC |
Supply frequency |
50/60 Hz, fLN, Main circuit
|
Terminal capacity (stranded) |
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables 1 x (2.5 - 95) mm², Main cables |
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated insulation voltage (Ui) |
660 V
|
Rated operational current (Ie) at AC-11 |
3 A
|
Rated operational current (Ie) at AC-53 |
135 A
|
Rated operational current (Ie) at AC-53, in-delta |
234 A
|
Rated operational current for specified heat dissipation (In) |
135 A
|
Rated operational power at 220/230 V, 50 Hz |
37 kW
|
Rated operational power at 400 V, 50 Hz |
75 kW
|
Rated operational power at 500 V, 50 Hz |
90 kW
|
Rated operational power in-delta at 220/230 V, 50 Hz |
75 kW
|
Rated operational power in-delta at 400 V, 50 Hz |
132 kW
|
Rated operational power in-delta at 500 V, 50 Hz |
160 kW
|
Rated operational voltage (Ue) - max |
600 V
|
Ramp/run-up time |
180 s
|
Shock resistance |
15 g, Mechanical
|
Suitable for |
Branch circuits, not as BCPD, (UL/CSA)
|
Tightening torque |
11.3 Nm
0.4 Nm, Screw terminals, Control circuit cables |
Short-circuit protection rating |
NZMN2-S160, Type “1” coordination, Main conducting paths
|
Start voltage |
Max. 85 %, Soft start function, Start voltage = turn-off voltage
|
Startup class |
CLASS 10 (star-delta replacement)
CLASS 20 (heavy starting duty 3 x Iₑ for 45 s) CLASS 30 (6 x Iₑ for 30 s) |
Terminal capacity (flexible with ferrule) |
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables 1 x (2.5 - 95) mm², Main cables |
Terminal capacity (solid) |
2 x (1 - 2.5) mm², Control circuit cables
1 x (2.5 - 4) mm², Control circuit cables 1 x (2.5 - 95) mm², Main cables |
Terminal capacity (solid/stranded AWG) |
2 x (14 - 12), Control circuit cables
1 x (14 - 12), Control circuit cables 1 x (14 - 4/0), Main cables |