Reset
Eaton Moeller series xEffect - FRBm6/M RCBO - residual-current circuit breaker with overcurrent protection. RCD/MCB, 6A, 100mA, MCB trip type D, 1-phase+N, RCCB trip type: A
Product Name |
Eaton Moeller series xEffect - FRBm6/M RCBO - residual-current circuit breaker with overcurrent protection
|
Catalog Number |
170546
|
Product Length/Depth |
80 mm
|
Product Height |
75 mm
|
Product Width |
35 mm
|
Product Weight |
0.193 kg
|
Compliances |
RoHS conform
|
Certifications |
CE
EN45545-2 IEC 61373 |
Amperage Rating |
6 A
|
Voltage rating |
240 V - 240 V
|
Surge current capacity |
0.25 kA
|
Voltage type |
AC
|
Width in number of modular spacings |
2
|
Features |
Concurrently switching N-neutral
|
Operating ambient temperature - max |
40 °C
|
Operating ambient temperature - min |
-25 °C
|
Product range |
FRBmM
|
Rated current |
6 A
|
Rated fault currents of product range |
10, 30, 100, 300 MilliAmpere
|
Rated switching capacity (IEC/EN 61009) |
10 kA
|
Static heat dissipation, non-current-dependent |
0 W
|
Tripping characteristic |
D
|
Built-in depth |
75.5 mm
|
Current limiting class |
3
|
Rated short-circuit breaking capacity (EN 60947-2) |
15 kA
|
Ambient operating temperature - max |
40 °C
|
Ambient operating temperature - min |
-25 °C
|
Fault current rating |
0.1 A
|
Heat dissipation capacity |
0 W
|
Heat dissipation per pole, current-dependent |
0 W
|
Number of poles (protected) |
1
|
Number of poles (total) |
2
|
Rated operational voltage (Ue) - max |
240 V
|
Rated short-circuit breaking capacity (IEC 60947-2) |
15 kA
|
Rated switching capacity |
10 kA
|
Basic function |
Combined RCD/MCB devices
|
Mounting Method |
DIN rail
|
Rated impulse withstand voltage (Uimp) |
4 kV
|
Degree of protection |
IP20
|
Operating ambient temperature hint |
Keep in mind the derating at temperatures higher than 40 °C
|
Tripping |
Non-delayed
|
Overvoltage category |
III
|
Pollution degree |
2
|
Impulse withstand current |
Partly surge-proof, 250 A
|
Leakage current type |
A
|
Release characteristic |
D
|
Sensitivity type |
Pulse-current sensitive
|
Frequency rating |
50 Hz
|
Rated insulation voltage (Ui) |
500 V
|
Connectable conductor cross section (solid-core) - min |
1 mm²
|
Connectable conductor cross section (solid-core) - max |
25 mm²
|
Connectable conductor cross section (multi-wired) - min |
1 mm²
|
Connectable conductor cross section (multi-wired) - max |
25 mm²
|
Rated short-circuit breaking capacity (EN 61009) |
10 kA
|
Rated short-circuit breaking capacity (EN 61009-1) |
10 kA
|
Number of poles |
Single-pole + N
|
Disconnection characteristic |
Undelayed
|
Type |
RCBO
|
Application |
Switchgear for industrial and advanced commercial applications
|