Eaton EU1E SmartWire-DT IP67 T-Connector analog module, one 0 - 20 mA analog input with power supply, one M12 I/O socket
| Product Name |
Eaton EU1E Accessory Input module
|
| Catalog Number |
174718
|
| Product Length/Depth |
85.6 mm
|
| Product Height |
20.1 mm
|
| Product Width |
56.9 mm
|
| Product Weight |
0.07 kg
|
| Certifications |
UL File No.: E170645
CSA UL IEC/EN 61131-2 |
| Type |
Analog modules
|
| Features |
Short-circuit protection (sensor supply)
Input signal, configurable Input, current Analog outputs configurable Overload protection (sensor supply) Fieldbus connection over separate bus coupler possible Analog inputs configurable Fieldbus connection over separate bus coupler possible |
| Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Screw connection
|
| Pollution degree |
3
|
| Burst impulse |
1 kV, Signal cable, according to IEC/EN 61131-2, Level 3
2 kV, Supply cable, according to IEC/EN 61131-2, Level 3 1 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3 |
| Resolution |
12 Bit (Analog inputs)
|
| Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2 |
| Connection to SmartWire-DT |
Yes
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Explosion safety category for dust |
None
|
| Operating temperature - max |
70 °C
|
| Operating temperature - min |
-25 °C
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Resolution of the analog inputs |
12 Bit
|
| Static heat dissipation, non-current-dependent Pvs |
1.1 W
|
| Product category |
SmartWire-DT slave
|
| Power consumption |
1.1 W
|
| Environmental conditions |
Condensation: permissible
|
| Input |
Current
Input (0 - 20 mA) |
| Explosion safety category for gas |
None
|
| Mounting method |
Wall mounting/direct mounting
Mounting section (Clip M20) Screw fixing (M4) DIN rail Rail mounting possible |
| Current consumption |
46 mA, SmartWire-DT network
70 mA, Max. current consumption per M12 I/O plug, Sensor supply, SmartWire-DT network |
| Voltage type |
DC
|
| Mounting position |
As required
|
| Contact discharge |
4 kV, according to IEC/EN 61131-2, Level 2, ESD
|
| Overvoltage category |
II
|
| Dielectric strength |
30 kV/mm, according to IEC 60243-1
|
| Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
| Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
| Surge rating |
0.5 kV, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC
1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC |
| Potential isolation |
Input to input: no
Inputs for SmartWire-DT: no |
| Power loss |
1.1 W
|
| Conversions |
20 ms, Analog inputs
|
| Electromagnetic fields |
10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008)
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008) |
| Number of inputs (analog) |
1
|
| Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Protocol |
Other bus systems
|
| Radio interference class |
Class A (EN 55011)
|
| Relative humidity |
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
| Connection type |
SWD-OUT: M12 socket (A-keyed), 5 pole
5-pin M12 socket (A-keyed), Supply and I/O sensor SWD-IN : M12 plug (A-keyed), 5 pole |
| Repetition accuracy |
0.5 % (Analog inputs)
|
| Data transfer rate |
Setting automatically
2 MBit/s, SmartWire-DT |
| Degree of protection |
IP69K
NEMA 4X |
| Station |
SmartWire-DT slave, SmartWire-DT network
|
| Input impedance |
< 250 Ω
|
| Shock resistance |
30 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
| Functions |
For connection of analog I/O signals
Adjustable parameter settings |
| System accessory |
Yes
|
| Input current |
0 - 20 mA (Analog inputs)
|
| Total error |
± 1 %, Inputs
|
| LED indicator |
Status indication of SmartWire-DT network: Green LED
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
70 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
0
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
0
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Number of outputs (analog) |
0
|