Eaton XN-322 Analog I/O module, 2 analog inputs and 2 analog outputs, +/-10 V, Uref
| Product Name |
Eaton XN-322 I/O module
|
| Catalog Number |
183181
|
| Product Length/Depth |
104.2 mm
|
| Product Height |
16.8 mm
|
| Product Width |
80.3 mm
|
| Product Weight |
0.055 kg
|
| Certifications |
UL File No.: E135462
CE cULus EN 61131-2 EN 61000-6-2 EN 61000-6-4 UL508 CSA-C22.2 No. 142-M |
| Used with |
XN300
XN-312-… |
| Type |
|
| Features |
Analog outputs configurable
Output, voltage Input, voltage Analog inputs configurable Fieldbus connection over separate bus coupler possible Input signal, configurable |
| Air discharge |
8 kV
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Plug-in connection
|
| Fitted with: |
1 kHz, third-order low-pass input filter
Parameterizable Software input filter |
| Pollution degree |
3
|
| Accuracy |
± 0.5 % of full scale, Analog outputs
± 0.3 % of full scale, Voltage measurement |
| Burst impulse |
1 kV, Signal cable
2 kV, Supply cable |
| Number of channels |
2, Analog Inputs
|
| Resolution |
|
| Climatic proofing |
Dry heat to IEC 60068-2-2
Damp heat, constant, to IEC 60068-2-3 |
| Air pressure |
795 - 1080 hPa (operation)
|
| Explosion safety category for dust |
None
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Resolution of the analog inputs |
16 Bit
|
| Resolution of the analog outputs |
12 Bit
|
| Static heat dissipation, non-current-dependent Pvs |
1.952 W
|
| Stripping length (main cable) |
10 mm
|
| Supply voltage at AC, 50 Hz - max |
0 VAC
|
| Supply voltage at AC, 50 Hz - min |
0 VAC
|
| Supply voltage at AC, 60 Hz - max |
0 VAC
|
| Supply voltage at AC, 60 Hz - min |
0 VAC
|
| Supply voltage at DC - max |
30 VDC
|
| Supply voltage at DC - min |
18 VDC
|
| Product category |
XN-322 analog input and output module
|
| Power consumption |
1.2 W
|
| Environmental conditions |
Condensation: prevent with appropriate measures
|
| Input |
2 Analog inputs (±10 V, Uref)
|
| Output voltage |
-10 - 10 V DC (analog outputs)
|
| Explosion safety category for gas |
None
|
| Mounting method |
Rail mounting possible
|
| Current consumption |
55 mA (typ.), for +5 V power supply (internal), Power supply - Input
45 mA (typ.), for +24 V, Power supply - Input |
| Voltage type |
DC
|
| Mounting position |
Horizontal
|
| Output |
2 Analog Outputs (±10 V)
|
| Input voltage |
Max. 14 V DC
|
| Contact discharge |
4 kV
|
| Overvoltage category |
III
|
| Capacitive load |
0.1 µF, Analog outputs
|
| Surge rating |
1 kV, Signal cable, unbalanced, EMC
0.5/0.5 kV, Supply cable, balanced/unbalanced), EMC |
| Emitted interference |
47 dB (at 230 - 1000 MHz, Class A, radiated, high frequency)
40 dB (at 30 - 230 MHz, Class A, radiated, high frequency) |
| Potential isolation |
Analog inputs: no
Sensor/transmitter supply: no |
| Electromagnetic fields |
1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3)
10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3) 3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3) |
| Load current |
Not specified by plug manufacturer
|
| Number of inputs (analog) |
2
|
| Radiated RFI |
10 V
|
| Protocol |
Other bus systems
|
| Relative humidity |
0 - 95 % (non-condensing)
|
| Connection type |
2 conductors, Voltage measurement
Push-in spring-cage terminal (plug-in connection), Connection design in TOP direction 2 conductors, Analog outputs, Output voltage |
| Rated control supply voltage |
10 V (Sensor/transmitter supply)
|
| Rated operational current (Ie) |
Max. 0.0083 A (supply output)
|
| Rated operational voltage |
160 V (terminations)
|
| Refresh time |
1 ms (analog inputs, all channels)
|
| Degree of protection |
IP20
NEMA 1 |
| Gauge pin |
A1 (according to IEC/EN 60947-1)
|
| Short-circuit current |
30 mA, per channel, Analog outputs
|
| Resistive load |
> 5000 Ω, analog outputs
|
| Vibration resistance |
5 - 8.4 / 8.4 -150 Hz, 3,5 mm / 1 g
|
| Shock resistance |
15 g, Mechanical, Half-sinusoidal shock 11 ms, 18 Impacts
|
| Short-circuit protection |
Yes, Short-circuit strength, Analog outputs
|
| Insulating material group |
I
|
| Voltage measurement |
± 12 V DC, Common-mode range
Open wire monitoring. -10 - 10 V DC, Measurement range > 10 MΩ, Input resistance The channels can also be used as potentiometer inputs. |
| System accessory |
Yes
|
| Terminal capacity |
0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
0.2 - 1.5 mm², flexible without ferrule, H07V-K 24 - 16 AWG 0.2 - 1.5 mm², solid, H07V-U 0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight) |
| Value refresh time/cycle time |
Min. 1 / 1 ms (per channel / all channels), Analog Inputs
|
| Value representation |
SIGNED16, mV, Voltage measurement
|
| Voltage dips |
Voltage dips: 10 ms/Voltage fluctuations: Yes
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
60 °C
|
| Ambient operating temperature - min |
0 °C
|
| Ambient storage temperature - max |
85 °C
|
| Ambient storage temperature - min |
-20 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
1.018 W
|
| Height of fall (IEC/EN 60068-2-32) - max |
1 m
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
1
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
0
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Number of outputs (analog) |
2
|
| Limit frequency |
1 kHz (third-order low-pass filter)
|
| Measured variables |
Voltage or potentiometer
|