Eaton Moeller® series EMR6 Level monitoring relays, 110 - 130 V AC/220 - 240 V AC, 50/60 Hz, 0.1 - 1000 kΩ
Product Name |
Eaton Moeller® series EMR6 Liquid level monitoring relay
|
Catalog Number |
184756
|
Product Length/Depth |
103.7 mm
|
Product Height |
85.6 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.154 kg
|
Certifications |
GL
RCM EAC UL IEC/EN 60255-6 RMRS EN 61557 CSA DNV |
Type |
Level monitoring relay
|
Air discharge |
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
|
Electric connection type |
Screw connection
|
Pollution degree |
3
|
Power consumption |
2.6 VA
|
Burst impulse |
According to IEC/EN 61000-4-4, level 3
|
Connection |
Minimum level, MIN, Sensor inputs, Measuring circuits
Earth reference sensor, C, Sensor inputs, Measuring circuits Maximum level, MAX, Sensor inputs, Measuring circuits |
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
|
Adjustable off-delay time - min |
0 s
|
Adjustable operate delay time - min |
0 s
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
85 °C
|
Ambient storage temperature - min |
40 °C
|
Number of contacts (change-over contacts) |
1
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
0
|
Number of inputs for electrodes |
3
|
Permitted off-delay time - max |
0 s
|
Permitted operate delay time - max |
0 s
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
110 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
110 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Rated operational current (Ie) |
5 A at AC-12, 230 V
3 A at AC-15, 230 V 2 A at DC-12, 24 V |
Adjustment range |
0.1 - 1000 kΩ, Sensitivity
|
Lifespan, electrical |
100,000 Operation (at 230 V, AC-12, 4 A)
|
Screwdriver size |
5.5 x 0.8 mm, Terminal screw
|
Voltage type |
AC
|
Connection type |
Snap fixing, top-hat rail IEC/EN 60715
|
Mounting position |
As required
|
Shock resistance |
Class 2
|
Overvoltage category |
III
|
Short-circuit protection rating |
Max. 10 A Fast/gL, Fuse, Relay output contacts
|
Duty factor |
100 %, Power supply
|
Degree of protection |
Terminals: IP20
Enclosure: IP50 |
Supply voltage |
220 - 240 V AC, 50/60 Hz
110 - 130 V AC, 50/60 Hz |
Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
Electromagnetic compatibility |
According to IEC/EN 60947-6-2
|
Functions |
Response value sensitivity adjustable
|
Immunity to line-conducted interference |
Level 3 (according to IEC/EN 61000-4-6)
|
Tightening torque |
Min. 0.5 Nm, Screw terminals
0.8 Nm, Screw terminals |
Immunity to radiation |
Level 3 (according to IEC/EN 61000-4-3)
|
Voltage tolerance |
0.85 x Uc
1.1 x Uc |
LED indicator |
Status indication of Min occupied: Yellow, flashing light
Status indication of active release delay: Green, flashing light Status indication of Supply voltage: Green LED Status indication of Output relay excited: Yellow, solid light (R) Status indication of Min and Max occupied: Yellow, solid light Status indication of energized output relay: Yellow LED Status indication of Supply voltage: Green, solid light |
Lifespan, mechanical |
10,000,000 Operations
|
Monitoring function |
Mixture ratio of conductive liquids
Fill level of conductive liquids |
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated frequency - max |
60 Hz
|
Rated frequency - min |
50 Hz
|
Rated operational voltage (Ue) at AC - max |
300 V
|
Sensor voltage |
6 VAC
|
Product category |
EMR Measuring and monitoring relays
|
Physical measurement principle |
Conductive
|
Terminal capacity |
1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule |
Voltage type of supply voltage |
AC
|
Voltage type of operating voltage |
AC
|
Rated switch current |
4 A
|
Supply voltage at AC, 50 Hz - min |
110 V
|
Supply voltage at AC, 50 Hz - max |
240 V
|
Supply voltage at AC, 60 Hz - min |
110 V
|
Supply voltage at AC, 60 Hz - max |
240 V
|
Operating voltage at AC, 50 Hz - min |
110 V
|
Operating voltage at AC, 50 Hz - max |
240 V
|
Operating voltage at AC, 60 Hz - min |
110 V
|
Operating voltage at AC, 60 Hz - max |
240 V
|