Eaton Moeller® series EMR6 Level monitoring relays, 110 - 130 V AC, 50/60 Hz, 220 - 240 V AC, 50/60 Hz, 5 - 100 kΩ
| Product Name |
Eaton Moeller® series EMR6 Liquid level monitoring relay
|
| Catalog Number |
184758
|
| Product Length/Depth |
103.7 mm
|
| Product Height |
85.6 mm
|
| Product Width |
22.5 mm
|
| Product Weight |
0.153 kg
|
| Certifications |
CSA
RMRS EN 61557 RCM IEC/EN 60255-6 UL GL DNV EAC |
| Type |
Level monitoring relay
|
| Air discharge |
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
|
| Electric connection type |
Screw connection
|
| Pollution degree |
3
|
| Power consumption |
2.6 VA
|
| Burst impulse |
According to IEC/EN 61000-4-4, level 3
|
| Connection |
Minimum level, MIN, Sensor inputs, Measuring circuits
Maximum level, MAX, Sensor inputs, Measuring circuits Earth reference sensor, C, Sensor inputs, Measuring circuits |
| Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
|
| Adjustable off-delay time - min |
0 s
|
| Adjustable operate delay time - min |
0 s
|
| Ambient operating temperature - max |
60 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - max |
85 °C
|
| Ambient storage temperature - min |
40 °C
|
| Number of contacts (change-over contacts) |
1
|
| Number of contacts (normally closed contacts) |
0
|
| Number of contacts (normally open contacts) |
0
|
| Number of inputs for electrodes |
3
|
| Permitted off-delay time - max |
0 s
|
| Permitted operate delay time - max |
0 s
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
110 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
110 V
|
| Rated control supply voltage (Us) at DC - max |
0 V
|
| Rated impulse withstand voltage (Uimp) |
4000 V AC
|
| Rated operational current (Ie) |
5 A at AC-12, 230 V
3 A at AC-15, 230 V |
| Adjustment range |
5 - 100 kΩ, Sensitivity
|
| Lifespan, electrical |
100,000 Operation (at 230 V, AC-12, 4 A)
|
| Screwdriver size |
5.5 x 0.8 mm, Terminal screw
|
| Voltage type |
AC
|
| Connection type |
Snap fixing, top-hat rail IEC/EN 60715
|
| Mounting position |
As required
|
| Shock resistance |
Class 2
|
| Overvoltage category |
III
|
| Short-circuit protection rating |
Max. 10 A Fast/gL, Fuse, Relay output contacts
|
| Duty factor |
100 %, Power supply
|
| Degree of protection |
Terminals: IP20
Enclosure: IP50 |
| Supply voltage |
110 - 130 V AC, 50/60 Hz
220 - 240 V AC, 50/60 Hz |
| Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
| Electromagnetic compatibility |
According to IEC/EN 60947-6-2
|
| Functions |
Response value sensitivity adjustable
|
| Immunity to line-conducted interference |
Level 3 (according to IEC/EN 61000-4-6)
|
| Tightening torque |
Min. 0.5 Nm, Screw terminals
0.8 Nm, Screw terminals |
| Immunity to radiation |
Level 3 (according to IEC/EN 61000-4-3)
|
| Voltage tolerance |
1.1 x Uc
0.85 x Uc |
| LED indicator |
Status indication of Min occupied: Yellow, flashing light
Status indication of Supply voltage: Green, solid light Status indication of energized output relay: Yellow LED Status indication of Supply voltage: Green LED Status indication of Min and Max occupied: Yellow, solid light Status indication of active release delay: Green, flashing light Status indication of Output relay excited: Yellow, solid light (R) |
| Lifespan, mechanical |
10,000,000 Operations
|
| Monitoring function |
Mixture ratio of conductive liquids
Fill level of conductive liquids |
| Rated control supply voltage (Us) at DC - min |
0 V
|
| Rated frequency - max |
60 Hz
|
| Rated frequency - min |
50 Hz
|
| Rated operational voltage (Ue) at AC - max |
300 V
|
| Sensor voltage |
6 VAC
|
| Product category |
EMR Measuring and monitoring relays
|
| Physical measurement principle |
Conductive
|
| Terminal capacity |
1 x (0.5-2.5) mm², (1 x (18-14) AWG), solid
2 x (0.5-1.5) mm², (2 x (18-16) AWG), flexible with ferrule |
| Voltage type of supply voltage |
AC
|
| Voltage type of operating voltage |
AC
|
| Rated switch current |
4 A
|
| Supply voltage at AC, 50 Hz - min |
110 V
|
| Supply voltage at AC, 50 Hz - max |
240 V
|
| Supply voltage at AC, 60 Hz - min |
110 V
|
| Supply voltage at AC, 60 Hz - max |
240 V
|
| Supply voltage at DC - min |
110 V
|
| Supply voltage at DC - max |
240 V
|
| Operating voltage at AC, 50 Hz - min |
110 V
|
| Operating voltage at AC, 50 Hz - max |
240 V
|
| Operating voltage at AC, 60 Hz - min |
110 V
|
| Operating voltage at AC, 60 Hz - max |
240 V
|