Eaton Moeller® series EMR6 Insulation monitoring relays, 0 - 400 V AC, 1 - 100 kΩ
Product Name |
Eaton Moeller® series EMR6 Insulation monitoring relay
|
Catalog Number |
184773
|
Product Length/Depth |
103.7 mm
|
Product Height |
85.6 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.141 kg
|
Certifications |
IEC/EN 60255-6
|
Type |
Insulation monitoring relay
|
Air discharge |
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
|
Electric connection type |
Screw connection
|
Pollution degree |
3
|
Power consumption |
3.5 VA
|
Burst impulse |
According to IEC/EN 61000-4-4, level 3
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Rated operational current (Ie) |
5 A at AC-12, 230 V
|
Adjustment range |
1 - 100 kΩ, Sensitivity
|
Lifespan, electrical |
100,000 Operation (at 230 V, AC-12, 4 A)
|
Rated operational voltage of monitored supply system |
0 - 400 V AC
|
Screwdriver size |
5.5 x 0.8 mm, Terminal screw
|
Voltage type |
AC/DC
|
Connection type |
Snap fixing, top-hat rail IEC/EN 60715
|
Mounting position |
As required
|
Shock resistance |
Class 2
|
Overvoltage category |
III
|
Short-circuit protection rating |
Max. 10 A Fast/gL, Fuse, Relay output contacts
|
Duty factor |
100 %, Power supply
|
Degree of protection |
Terminals: IP20
Enclosure: IP50 |
Supply voltage |
24 - 240 V DC
24 - 240 V AC, 50/60 Hz |
Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
Electromagnetic compatibility |
According to IEC/EN 60947-6-2
|
Terminal capacity (flexible with ferrule AWG) |
2 x 18-16
|
Terminal capacity (flexible with ferrule) |
2 x 0.5-1.5 mm²
|
Terminal capacity (solid AWG) |
18 - 14
|
Functions |
Error registration possible
Status indication via LEDs Configurable non-volatile fault memory Configurable memory function For AC-current system Configurable fault memory |
Terminal capacity (solid) |
1 x 0.5-2.5 mm²
|
Hysteresis |
25 %
|
Immunity to line-conducted interference |
Level 3 (according to IEC/EN 61000-4-6)
|
Tightening torque |
0.8 Nm, Screw terminals
Min. 0.5 Nm, Screw terminals |
Immunity to radiation |
Level 3 (according to IEC/EN 61000-4-3)
|
Voltage tolerance |
1.1 x Uc
0.85 x Uc |
LED indicator |
Status indication of Supply voltage: Green, solid light
Status indication of Faults at L-: Red LED Status indication of Supply voltage: Green LED Other states depending on fault (see IL): Measured value Status indication of Faults at L+: Red LED |
Lifespan, mechanical |
30,000,000 Operations
|
Monitoring function |
Insulation resistance in non-earthed AC supply systems (two-phase, three-phase, four-phase systems)
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
85 °C
|
Ambient storage temperature - min |
-40 °C
|
Line capacity |
10 µF
|
Number of contacts (change-over contacts) |
1
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
0
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
240 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated frequency - max |
60 Hz
|
Rated frequency - min |
15 Hz
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
3 A
|
Cable length |
10 m
|
Rated operational current (Ie) at DC-13, 24 V |
2.5 A
|
Rated operational voltage (Ue) - max |
400 V
|
Rated operational voltage (Ue) - min |
0 V
|
Response value impedance 1 - max |
100 kΩ
|
Response value impedance 1 - min |
1 kΩ
|
Response value impedance 2 - max |
0 kΩ
|
Response value impedance 2 - min |
0 kΩ
|
Product category |
EMR Measuring and monitoring relays
|
Voltage measurement - min |
0 V
|
Voltage measurement - max |
400 V
|
Voltage type of supply voltage |
AC
|
Voltage type of operating voltage |
AC
|
Rated switch current |
4 A
|
Supply voltage at AC, 50 Hz - min |
0 V
|
Supply voltage at AC, 50 Hz - max |
400 V
|
Supply voltage at AC, 60 Hz - min |
0 V
|
Supply voltage at AC, 60 Hz - max |
400 V
|
Supply voltage at DC - min |
0 V
|
Supply voltage at DC - max |
0 V
|
Operating voltage at AC, 50 Hz - min |
0 V
|
Operating voltage at AC, 50 Hz - max |
400 V
|
Operating voltage at AC, 60 Hz - min |
0 V
|
Operating voltage at AC, 60 Hz - max |
400 V
|
Operating voltage at DC - min |
0 V
|
Operating voltage at DC - max |
0 V
|