Eaton Moeller® series EMR6 Overcurrent and undercurrent monitor, Current measuring range: 3 - 30 mA, 10 - 100 mA, 0.1 - 1 A, Supply voltage: 24 - 240 V AC, 50/60 Hz, 24 - 240 V DC
Product Name |
Eaton Moeller® series EMR6 Overcurrent and undercurrent monitor
|
Catalog Number |
184790
|
Product Length/Depth |
103.7 mm
|
Product Height |
85.6 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.152 kg
|
Certifications |
UL 508
RMRS CSA-C22.2 No. 14 CCC GL EAC |
Catalog Notes |
Extension of the measurement range possible with current transformers
|
Type |
Current monitoring relay
|
Air discharge |
Air/contact discharge, according to IEC/EN 61000-4-2, level 3
|
Electric connection type |
Screw connection
|
Pollution degree |
3
|
Power consumption |
2.6 VA
|
Burst impulse |
According to IEC/EN 61000-4-4, level 3
|
Climatic proofing |
Damp heat, cyclic, to IEC 60068-2-30
|
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Rated operational current (Ie) |
4 A at AC-12, 230 V
4 A at DC-12, 24 V |
Lifespan, electrical |
100,000 Operation (at 230 V, AC-12, 4 A)
|
Screwdriver size |
4 x 0.8 mm, Terminal screw
|
Voltage type |
AC/DC
|
Connection type |
Snap fixing, top-hat rail IEC/EN 60715
|
Mounting position |
As required
|
Shock resistance |
Class 2
|
Overvoltage category |
III
|
Short-circuit protection rating |
Max. 10 A Fast/gL, Fuse, Relay output contacts
|
Duty factor |
100 %, Power supply
|
Degree of protection |
Enclosure: IP50
Terminals: IP20 |
Supply voltage |
24 - 240 V AC, 50/60 Hz
24 - 240 V DC |
Delay time |
On delay: None = 0 or adjustable from 0.1 to 30 s
|
Surge rating |
According to IEC/EN 61000-4-5 Level 4
|
Electromagnetic compatibility |
According to IEC/EN 60947-6-2
|
Temperature error |
0.06 %/°C, Measuring circuits
|
Terminal capacity (flexible with ferrule AWG) |
2 x 18-16
|
Terminal capacity (flexible with ferrule) |
2 x 0.5-1.5 mm²
|
Terminal capacity (solid AWG) |
18 - 14
|
Functions |
DC-voltage under current
Single-phase over current possible Single-phase under current possible Monitoring of single-phase DC and AC networks DC-voltage over current |
Terminal capacity (solid) |
1 x 0.5-2.5 mm²
|
Hysteresis |
3 - 30 %
|
Immunity to line-conducted interference |
Level 3 (according to IEC/EN 61000-4-6)
|
Tightening torque |
Min. 0.6 Nm, Screw terminals
0.8 Nm, Screw terminals |
Immunity to radiation |
Level 3 (according to IEC/EN 61000-4-3)
|
Voltage tolerance |
1.1 x Uc
0.85 x Uc |
Timing cycle |
0.06 %/°C, Time error within temperature range
Adjustable from 0.1 – 30 s, Reset delay/Off-delay time 0.5 % Error within supply voltage (Measuring circuits) 0.5 %, Time error within supply voltage |
LED indicator |
Status indication of active release delay: Green, flashing light
Status indication of energized output relay: Yellow LED Status indication of Supply voltage: Green, solid light Status indication of Output relay excited: Yellow, solid light Status indication of measured value: Red LED Status indication of Undercurrent: Red, flashing light Status indication of Supply voltage: Green LED |
Lifespan, mechanical |
30,000,000 Operations
|
Monitoring function |
Overcurrent
Undercurrent |
Adjustable delay-on energization time - min |
0.1 s
|
Adjustable off-delay time - min |
0 s
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
85 °C
|
Ambient storage temperature - min |
40 °C
|
Current measurement - max |
1 A
|
Current measurement - min |
0.01 A
|
Measuring cycle |
80 ms
|
Number of contacts (change-over contacts) |
2
|
Number of contacts (normally closed contacts) |
0
|
Number of contacts (normally open contacts) |
0
|
Permitted delay-on energization time - max |
30 s
|
Permitted off-delay time - max |
0 s
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Input current |
Input B2-C: 0.01 - 0.1 A
Input B1-C: 0.003 - 0.03 A Input B3-C: 0.1 - 1 A |
Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
Rated control supply voltage (Us) at DC - max |
240 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated frequency - max |
60 Hz
|
Rated frequency - min |
50 Hz
|
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V |
3 A
|
Rated operational current (Ie) at DC-13, 24 V |
2 A
|
Rated operational voltage (Ue) at AC - max |
250 V
|
Product category |
EMR Measuring and monitoring relays
|
Type of current |
AC/DC
|
Voltage measurement - min |
24 V
|
Voltage measurement - max |
240 V
|
Voltage type of supply voltage |
AC/DC
|
Voltage type of operating voltage |
AC/DC
|
Rated switch current |
4 A
|
Supply voltage at AC, 50 Hz - min |
24 V
|
Supply voltage at AC, 50 Hz - max |
240 V
|
Supply voltage at AC, 60 Hz - min |
24 V
|
Supply voltage at AC, 60 Hz - max |
240 V
|
Supply voltage at DC - min |
24 V
|
Supply voltage at DC - max |
240 V
|
Response value amperage 1 - min |
0.1 A
|
Response value amperage 1 - max |
1 A
|
Response value amperage 2 - min |
0.003 A
|
Response value amperage 2 - max |
0.03 A
|
Operating voltage at AC, 50 Hz - min |
24 V
|
Operating voltage at AC, 50 Hz - max |
240 V
|
Operating voltage at AC, 60 Hz - min |
24 V
|
Operating voltage at AC, 60 Hz - max |
240 V
|
Operating voltage at DC - min |
24 V
|
Operating voltage at DC - max |
240 V
|