| Product Name |
Eaton xComfort KLV pre-wired distribution board
|
| Catalog Number |
194711
|
| Product Length/Depth |
96.5 mm
|
| Product Height |
714 mm
|
| Product Width |
359 mm
|
| Product Weight |
8.278 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC/EN 61439-3
|
| Special features |
IP30
Protection Class II
Plastic enclosure with sheet steel door, white (RAL 9016)
|
| Type |
Basic device
Installation distribution boards
KLV energy
|
| Voltage rating |
400 V AC
|
| Features |
Protection dual RCD
Protection high integrity Protection main switch Protection incoming RCD Protection split load |
| 10.10 Temperature rise |
The requirements of the product standard have been met.
|
| 10.11 Short-circuit rating |
The requirements of the product standard have been met.
|
| 10.12 Electromagnetic compatibility |
The requirements of the product standard have been met.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
850 °C
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Not relevant to indoor installations.
|
| 10.2.5 Lifting |
Does not apply to enclosures without lifting aids.
|
| 10.2.6 Mechanical impact |
IK05
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
IP30
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Protection class 2, therefore not applicable.
|
| 10.6 Incorporation of switching devices and components |
The requirements of the product standard have been met.
|
| 10.7 Internal electrical circuits and connections |
The requirements of the product standard have been met.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Ui = 400 V AC
|
| 10.9.3 Impulse withstand voltage |
4 kV
|
| 10.9.4 Testing of enclosures made of insulating material |
Meets the product standard's requirements.
|
| Fitted with: |
Cable retainer
Wired and tested in conformity with EN 61439-3 Door/Frame Front cover Nail lugs Neutral and protective conductor terminals with KSK plug-in terminal technology 2 residual current circuit-breaker PXF-40/4/003-A Imprintable sheet Installation instructions 1 surge protective device SPCT2-335-3+NPE Wall trough 3D adjustment element for mounting designed to adjust the mounting depth by up to 18 mm 1 miniature circuit breaker PXL-C40/3 Device support rails Empty section cover Spirit level for leveling 16 Miniature circuit breaker PLI-B16/1 |
| Frequency rating |
50 Hz
|
| Enclosure material |
Plastic
|
| Cable entry postion |
Cable entries on top and bottom, side, back plate
|
| Type of over voltage protection device |
Type 2
|
| Terminal type |
Screw terminals + Plug-in terminals
|
| Current rating of main switch |
32 A
|
| Heat diss. ambient 35°C delta T:20°C flush mount individ. encl. top(IEC 60890) |
45 W
|
| Heat diss. ambient 35°C delta T:35°C flush mount individ. encl. top(IEC 60890) |
48 W
|
| Number of circuit breakers (earth leakage) |
0
|
| Number of direct groups |
2
|
| Number of groups (total) |
0
|
| Closure type |
Other
|
| Cover/door color |
White
|
| Number of groups behind earth leakage switch |
2
|
| Number of light groups protected by 30 mA |
0
|
| Number of phases |
3
|
| Number of poles at main switch |
3
|
| Number of switches (earth leakage 30 mA) |
2
|
| Width in number of modular spacings |
12
|
| Ambient operating temperature details |
-5 °C - 40 °C
|
| Application |
Indoor (installation site)
|
| Number of switches (earth leakage 300 mA) |
0
|
| Color |
Traffic white (RAL 9016)
White |
| Number of rows |
4
|
| Frequency rating of contacts |
50 Hz
|
| Cooker group |
None
|
| Installation type |
Hollow-wall mounting and flush mounting
|
| Module rack type |
Rail frame
|
| Degree of protection |
IK05 (impact resistance)
IP30 |
| Number of module space units per row |
12
|
| Protection class |
II (totally insulated)
|
| Protective shrouding material |
Plastic
|
| Rocker color |
White
|
| Functions |
Over voltage protection
Basic device |
| Protected by |
Miniature- / earth leakage circuit breaker
|
| Material |
Polystyren (plastic)
Sheet steel, powder-coated |
| Mounting method |
Hollow-wall mounting and flush mounting
Hollow wall Flush mounted (plaster) Flush mounting |
| PE and N terminal number and cross section |
N: 4 x (2.5 mm² - 25 mm²) + 28 x (0.5 mm² - 4 mm²)
PE: 4 x (2.5 mm² - 25 mm²) + 28 x (0.5 mm² - 4 mm²) |
| Number of arc fault detection devices AFDD |
0
|
| Number of outgoing ways |
16
|
| Built-in height |
45 mm
|
| Built-in width |
251 mm
|
| RAL-number |
9016
|
| Type of covering |
Door
|
| Release characteristic |
B
|
| Rated short-circuit breaking capacity (EN 60898) at 230 V |
10 kA
|
| Number of single-phase miniature circuit breakers (MCB) |
16
|
| Number of three-phase miniature circuit breakers (MCB) |
1
|
| Connection type |
Push-in clamp
|
| Number of earth leakage circuit breakers/AFDD |
0
|