重置
重置
| Product Name |
Eaton Moeller® series EASY I/O expansion
|
| Catalog Number |
197224
|
| Product Length/Depth |
58 mm
|
| Product Height |
90 mm
|
| Product Width |
36 mm
|
| Product Weight |
0.1 kg
|
| Certifications |
UL File No.: E205091
CE UL hazardous location group A (acetylene) UL hazardous location group B (hydrogen) UL hazardous location division 2 UL hazardous location group C (ethylene) UL hazardous location class I UL hazardous location group D (propane) cULus Ordinary Location DNV TAA00002HT cULus Hazard Location UL File No.: E523283 EN 61131-2 IEC 61131-2 EN IEC 61000-6-3 IEC 61000-6-3 EN IEC 61010-2-201 IEC 61010-2-201 UL 61010-1 UL 61010-2-201 CSA C22.2 No. 61010-1 CSA C22.2 No. 61010-2-201 UL 121201 CSA C22.2 No. 213 |
| Used with |
easyE4
|
| Type |
easyE4 extension
|
| Features |
Expandable
Expansion device |
| Air discharge |
8 kV
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Pollution degree |
2
|
| Burst impulse |
2 kV, I/O port
2 kV, Power supply port According to IEC/EN 61131-2 |
| Air pressure |
795 - 1080 hPa (operation)
|
| Category (EN 954-1) |
None
|
| Explosion safety category for dust |
None
|
| Environmental conditions |
Condensation: prevent with appropriate measures
Clearance in air and creepage distances according to EN 50178, EN 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-201 |
| Input |
Input type resistance sensor: Platinum sensor Pt100 (according to DIN EN 60751, IEC 751)
Input type resistance sensor: Nickel sensor Ni1000 (according to DIN 43760) |
| Explosion safety category for gas |
None
|
| Mounting method |
Rail mounting possible
Top-hat rail fixing (according to IEC/EN 60715, 35 mm) Wall mounting/direct mounting Screw fixing using fixing brackets ZB4-101-GF1 (accessories) Front build in possible |
| Screwdriver size |
3.5 x 0.6 mm, Terminal screw
|
| Voltage type |
DC
|
| Mounting position |
Horizontal
Vertical |
| Contact discharge |
6 kV
|
| Base type |
No
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
0
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
0
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Overvoltage category |
Power supply + Temperature inputs + Right extension interface: II
Left extension interface: III |
| Software |
EASYSOFT-SWLIC/easySoft
|
| Surge rating |
0.5 kV, Line-to-Line, Power supply port
1 kV, Line-to-Earth, Power supply port According to IEC/EN 61131-2 |
| Cable length |
Temperature inputs: ≤ 30 m (unshielded)
|
| Electromagnetic fields |
10 V/m at 0.08 - 1.0 GHz (according to IEC/EN 61131-2)
3 V/m at 1.0 - 6 GHz (according to IEC/EN 61131-2) |
| Protection against polarity reversal |
Yes
|
| Number of inputs (analog) |
4
|
| Connection type |
Screw terminal
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Immunity to line-conducted interference |
10 V (according to IEC/EN 61131-2)
|
| Radio interference class |
Class B (EN 61000-6-3)
|
| Number of outputs (digital) |
0
|
| Relative humidity |
5 - 95 % (IEC 60068-2-30, IEC 60068-2-78)
|
| Degree of protection |
IP20
|
| Residual ripple |
Power supply: ≤ 5 %
|
| Insulation resistance |
According to EN IEC 61010-2-201, UL61010-2-201, CSA-C22.2 NO. 61010-2-221
|
| Vibration resistance |
8.4 - 150 Hz, 1 g constant acceleration
5 - 8.4 Hz, 3.5 mm constant amplitude According to IEC/EN 61131-2 |
| Shock resistance |
15 g, Mechanical, acc. to IEC/EN61131-2, Half-sinusoidal shock 11 ms, 18 Impacts
|
| LED indicator |
Status indication of Power/RUN
|
| Potential isolation |
POW+Temp. inputs+right Extension interface vs. left Extension interface: yes
|
| Number of inputs (digital) |
0
|
| Voltage dips |
10 ms
|
| Number of interfaces (PROFINET) |
0
|
| Number of outputs (analog) |
0
|
| Static heat dissipation, non-current-dependent Pvs |
1 W
|
| Supply voltage at DC - max |
28.8 VDC
|
| Supply voltage at DC - min |
20.4 VDC
|
| Product category |
Control relays easyE4
|
| Resolution |
12 Bit (0- 4095, digital, scaling per sensor)
|
| Power consumption |
1 W
|
| Rated operational voltage |
Power supply: 24 V DC (-15 %/+ 20 %)
|
| Short-circuit protection |
≥ 1A (T), Fuse, Power supply
|
| Terminal capacity |
0.2 - 4 mm² (AWG 22 - 12), solid
0.2 - 2.5 mm², flexible with ferrule 0.2 - 2.5 mm², flexible without ferrule |
| Tightening torque |
0.6 Nm, Screw terminals
|