Eaton Moeller® series DILMT Power contactor, 3 pole, 380 V 400 V: 15 kW, 24 V 50/60 Hz, AC operation, Screw terminals
| Product Name | 
                                            
                                            
                                             
                                                Eaton Moeller® series DILMT Contactor
                                             
                                         | 
                                    
| Catalog Number | 
                                            
                                            
                                             
                                                197618
                                             
                                         | 
                                    
| Product Length/Depth | 
                                            
                                            
                                             
                                                97.5 mm
                                             
                                         | 
                                    
| Product Height | 
                                            
                                            
                                             
                                                82 mm
                                             
                                         | 
                                    
| Product Width | 
                                            
                                            
                                             
                                                36 mm
                                             
                                         | 
                                    
| Product Weight | 
                                            
                                            
                                             
                                                0.36 kg
                                             
                                         | 
                                    
| Certifications | 
                                            
                                            
                                             
                                                EN 60335-1  
                                        GB14048 IEC/EN 60947  | 
                                    
| Catalog Notes | 
                                            
                                            
                                             
                                                Also tested according to AC-3e.
                                             
                                         | 
                                    
| Used with | 
                                            
                                            
                                             
                                                DILT-XHI01(10)
                                             
                                         | 
                                    
| Number of poles | 
                                            
                                            
                                             
                                                Three-pole
                                             
                                         | 
                                    
| 10.10 Temperature rise | 
                                            
                                            
                                             
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             
                                         | 
                                    
| 10.11 Short-circuit rating | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.12 Electromagnetic compatibility | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.13 Mechanical function | 
                                            
                                            
                                             
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             
                                         | 
                                    
| 10.2.2 Corrosion resistance | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.5 Lifting | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.6 Mechanical impact | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.7 Inscriptions | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.3 Degree of protection of assemblies | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.4 Clearances and creepage distances | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.5 Protection against electric shock | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.6 Incorporation of switching devices and components | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.7 Internal electrical circuits and connections | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.8 Connections for external conductors | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.2 Power-frequency electric strength | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.3 Impulse withstand voltage | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.4 Testing of enclosures made of insulating material | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| Operating frequency | 
                                            
                                            
                                             
                                                3600 mechanical Operations/h (AC operated)
                                             
                                         | 
                                    
| Pollution degree | 
                                            
                                            
                                             
                                                3
                                             
                                         | 
                                    
| Utilization category | 
                                            
                                            
                                             
                                                AC-1: Non-inductive or slightly inductive loads, resistance furnaces  
                                        AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching  | 
                                    
| Climatic proofing | 
                                            
                                            
                                             
                                                Damp heat, cyclic, to IEC 60068-2-30  
                                        Damp heat, constant, to IEC 60068-2-78  | 
                                    
| Connection to SmartWire-DT | 
                                            
                                            
                                             
                                                No
                                             
                                         | 
                                    
| Rated impulse withstand voltage (Uimp) | 
                                            
                                            
                                             
                                                6000 V AC
                                             
                                         | 
                                    
| Connection | 
                                            
                                            
                                             
                                                Screw terminals
                                             
                                         | 
                                    
| Frame size | 
                                            
                                            
                                             
                                                FS2
                                             
                                         | 
                                    
| Ambient operating temperature - max | 
                                            
                                            
                                             
                                                55 °C
                                             
                                         | 
                                    
| Ambient operating temperature - min | 
                                            
                                            
                                             
                                                -25 °C
                                             
                                         | 
                                    
| Ambient storage temperature - max | 
                                            
                                            
                                             
                                                80 °C
                                             
                                         | 
                                    
| Ambient storage temperature - min | 
                                            
                                            
                                             
                                                -40 °C
                                             
                                         | 
                                    
| Heat dissipation capacity Pdiss | 
                                            
                                            
                                             
                                                0 W
                                             
                                         | 
                                    
| Application | 
                                            
                                            
                                             
                                                Contactors for Motors
                                             
                                         | 
                                    
| Product category | 
                                            
                                            
                                             
                                                Contactors
                                             
                                         | 
                                    
| Electrical connection type of main circuit | 
                                            
                                            
                                             
                                                Screw connection
                                             
                                         | 
                                    
| Screwdriver size | 
                                            
                                            
                                             
                                                2, Terminal screw, Pozidriv screwdriver  
                                        2, Terminal screw, Control circuit cables, Pozidriv screwdriver  | 
                                    
| Voltage type | 
                                            
                                            
                                             
                                                AC
                                             
                                         | 
                                    
| Degree of protection | 
                                            
                                            
                                             
                                                IP20
                                             
                                         | 
                                    
| Number of auxiliary contacts (normally closed contacts) | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of auxiliary contacts (normally open contacts) | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of contacts (normally closed) as main contact | 
                                            
                                            
                                             
                                                0
                                             
                                         | 
                                    
| Number of main contacts (normally open contact) | 
                                            
                                            
                                             
                                                3
                                             
                                         | 
                                    
| Rated breaking capacity at 380/400 V | 
                                            
                                            
                                             
                                                256 A
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Overvoltage category | 
                                            
                                            
                                             
                                                III
                                             
                                         | 
                                    
| Duty factor | 
                                            
                                            
                                             
                                                100 %
                                             
                                         | 
                                    
| Lifespan, mechanical | 
                                            
                                            
                                             
                                                10,000,000 Operations (AC operated)
                                             
                                         | 
                                    
| Pick-up voltage | 
                                            
                                            
                                             
                                                0.85 - 1.1 V AC x Uc
                                             
                                         | 
                                    
| Power consumption, pick-up, 50 Hz | 
                                            
                                            
                                             
                                                0 VA, Dual-frequency coil in a cold state and 1.0 x Us  
                                        85 VA, Dual-frequency coil in a cold state and 1.0 x Us  | 
                                    
| Power consumption, pick-up, 60 Hz | 
                                            
                                            
                                             
                                                85 VA, Dual-frequency coil in a cold state and 1.0 x Us  
                                        0 VA, Dual-frequency coil in a cold state and 1.0 x Us  | 
                                    
| Screw size | 
                                            
                                            
                                             
                                                M3.5, Terminal screw  
                                        M5, Terminal screw  | 
                                    
| Power consumption, sealing, 50 Hz | 
                                            
                                            
                                             
                                                2.5 W, Dual-frequency coil in a cold state and 1.0 x Us  
                                        2.6 VA, Coil in a cold state and 1.0 x Us 0 W, Dual-frequency coil in a cold state and 1.0 x Us  | 
                                    
| Power consumption, sealing, 60 Hz | 
                                            
                                            
                                             
                                                0 W, Dual-frequency coil in a cold state and 1.0 x Us  
                                        0 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 8.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 2.5 W, Dual-frequency coil in a cold state and 1.0 x Us  | 
                                    
| Terminal capacity (stranded) | 
                                            
                                            
                                             
                                                2 x (1 - 10) mm²  
                                        1 x (1 - 10) mm²  | 
                                    
| Lifespan, electrical | 
                                            
                                            
                                             
                                                1,000,000 Operations (at 400V, AC-3)
                                             
                                         | 
                                    
| Terminal capacity (solid) | 
                                            
                                            
                                             
                                                1 x (1 - 10) mm², Main cables  
                                        1 x (0.75 - 2.5) mm² 2 x (0.75 - 2.5) mm²  | 
                                    
| Tightening torque | 
                                            
                                            
                                             
                                                2 Nm, Threaded ring  
                                        0.8 Nm, Screw terminals  | 
                                    
| Rated control supply voltage (Us) at DC - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated insulation voltage (Ui) | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 
                                            
                                            
                                             
                                                40 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 
                                            
                                            
                                             
                                                32 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 
                                            
                                            
                                             
                                                32 A
                                             
                                         | 
                                    
| Rated operational current (Ie) at AC-4, 400 V | 
                                            
                                            
                                             
                                                0 A
                                             
                                         | 
                                    
| Rated operational power at AC-3, 240 V, 50 Hz | 
                                            
                                            
                                             
                                                10 kW
                                             
                                         | 
                                    
| Rated operational power at AC-3, 380/400 V, 50 Hz | 
                                            
                                            
                                             
                                                15 kW
                                             
                                         | 
                                    
| Rated operational power at AC-4, 380/400 V, 50 Hz | 
                                            
                                            
                                             
                                                0 kW
                                             
                                         | 
                                    
| Rated operational power (NEMA) | 
                                            
                                            
                                             
                                                0 kW
                                             
                                         | 
                                    
| Rated operational voltage (Ue) at AC - max | 
                                            
                                            
                                             
                                                660 V
                                             
                                         | 
                                    
| Stripping length (main cable) | 
                                            
                                            
                                             
                                                14 mm
                                             
                                         | 
                                    
| Suitable for | 
                                            
                                            
                                             
                                                Also motors with efficiency class IE3
                                             
                                         | 
                                    
| Conventional thermal current Ith at 40°C (3-pole, open) | 
                                            
                                            
                                             
                                                40 A
                                             
                                         | 
                                    
| Actuating voltage | 
                                            
                                            
                                             
                                                24 V 50/60 Hz
                                             
                                         | 
                                    
| Operating voltage at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Operating voltage at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         | 
                                    
| Operating voltage at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                24 V
                                             
                                         | 
                                    
| Operating voltage at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                690 V
                                             
                                         |