Eaton Moeller® series Rapid Link DOL starter, 6.6 A, Sensor input 2, 230/277 V AC, AS-Interface®, S-7.A.E. for 62 modules, HAN Q5
Product Name |
Eaton Rapid Link DOL starter
|
Catalog Number |
198521
|
Product Length/Depth |
120 mm
|
Product Height |
270 mm
|
Product Width |
220 mm
|
Product Weight |
1.63 kg
|
Certifications |
RoHS
CE UL 60947-4-2 IEC/EN 60947-4-2 CCC UL approval UL 60947-4-2 |
Catalog Notes |
Assigned motor rating: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm at 50 Hz or 1800 min at 60 Hz
|
Type |
DOL starter
|
Features |
Parameterization: drivesConnect mobile (App)
Diagnostics and reset on device and via AS-Interface Parameterization: Fieldbus Parameterization: drivesConnect Parameterization: Keypad |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Key switch position HAND
Electronic motor protection Key switch position AUTO Thermo-click Thermistor monitoring PTC Short-circuit release Two sensor inputs through M12 sockets (max. 150 mA) for quick stop and interlocked manual operation Key switch position OFF/RESET |
Class |
CLASS 10 A
|
Lifespan, electrical |
10,000,000 Operations (at AC-3)
|
Climatic proofing |
In accordance with IEC/EN 50178
< 95 %, no condensation |
Rated impulse withstand voltage (Uimp) |
4000 V
|
Model |
Direct starter
|
Altitude |
Max. 2000 m
Above 1000 m with 1 % performance reduction per 100 m Max. 1000 m |
Lifespan, mechanical |
10,000,000 Operations (at AC-3)
|
Mains switch-on frequency |
Maximum of one time every 60 seconds
|
Electrical connection type of main circuit |
Plug-in connection
|
Mains voltage tolerance |
380 - 480 V (-15 %/+10 %, at 50/60 Hz)
|
Voltage type |
DC
|
Mounting position |
Vertical
|
Rated conditional short-circuit current (Iq) |
10 kA
|
Overvoltage category |
III
|
Connection |
Connections pluggable in power section
|
Off-delay |
20 - 35 ms
|
Functions |
Temperature compensated overload protection
External reset possible For actuation of motors with mechanical brake |
On-delay |
20 - 35 ms
|
System configuration type |
Center-point earthed star network (TN-S network)
AC voltage Phase-earthed AC supply systems are not permitted. |
Braking current |
≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
|
Electromagnetic compatibility |
Class A
|
Current limitation |
0.3 - 6.6 A, motor, main circuit
Adjustable, motor, main circuit |
Output frequency |
50/60 Hz
|
Braking voltage |
230/277 V AC -15 % / +10 %, Actuator for external motor brake
|
Overload cycle |
AC-53a
|
Overload release current setting - min |
0.3 A
|
Rated conditional short-circuit current (Iq), type 2, 230 V |
0 A
|
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V |
0 A
|
Rated conditional short-circuit current, type 1, 480 Y/277 V |
65000 A
|
Rated conditional short-circuit current, type 1, 600 Y/347 V |
0 A
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated frequency - max |
63 Hz
|
Rated frequency - min |
47 Hz
|
Rated operational current (Ie) at 150% overload |
6.6 A
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
6.6 A
|
Shock resistance |
15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms, Half-sinusoidal shock 11 ms, 1000 shocks per shaft
|
Interfaces |
Specification: S-7.A.E. (AS-Interface®)
Max. total power consumption from AS-Interface® power supply unit (30 V): 190 mA Number of slave addresses: 62 (AS-Interface®) |
Protocol |
ASI
AS-Interface profile cable: S-7.4 for 62 modules |
Rated control voltage (Uc) |
24 V DC (-15 %/+20 %, external via AS-Interface® plug)
230/277 V AC (external brake 50/60 Hz) |
Supply frequency |
50/60 Hz, fLN, Main circuit
|
Rated operational current (Ie) |
6.6 A
|
Rated operational power at 380/400 V, 50 Hz - max |
3 kW
|
Rated operational power at 380/400 V, 50 Hz - min |
0.09 kW
|
Rated operational voltage |
480 V AC, 3-phase
400 V AC, 3-phase |
Short-circuit protection (external output circuits) |
Type 1 coordination via the power bus' feeder unit, Main circuit
|
Vibration |
Resistance: 57 Hz, Amplitude transition frequency on acceleration
Resistance: 6 Hz, Amplitude 0.15 mm Resistance: According to IEC/EN 60068-2-6 Resistance: 10 - 150 Hz, Oscillation frequency |
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-10 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
3 HP
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Number of command positions |
1
|
Number of pilot lights |
0
|
Overload release current setting - max |
6.6 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
0 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
3 kW
|
Rated power at 460 V, 60 Hz, 3-phase |
2.238 kW
|
Rated power at 575 V, 60 Hz, 3-phase |
0 kW
|
Product category |
Motor starter
|
Cable length |
10 m, Radio interference level, maximum motor cable length
|
Coordination class (IEC 60947-4-3) |
Class 1
|
Degree of protection |
NEMA 12
IP65 |
Electrical connection type for auxiliary- and control-current circuit |
Plug-in connection
|
Input current |
6.6 A (at 150 % Overload)
|
Power consumption |
8 W
|