Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 3.7 kW, 1 N/O, 1 NC, 230 V 50 Hz, 240 V 60 Hz, AC operation, Push in terminals
| Product Name | 
                                                Eaton Moeller® series DILM contactor
                                             | 
| Catalog Number | 
                                                199264
                                             | 
| Product Length/Depth | 
                                                115 mm
                                             | 
| Product Height | 
                                                85 mm
                                             | 
| Product Width | 
                                                45 mm
                                             | 
| Product Weight | 
                                                0.441 kg
                                             | 
| Certifications | 
                                                VDE 0660  IEC/EN 60947 UL Listed CSA certified UL Category Control No.: NLDX CE marking UL File No.: E29096 CSA Class No.: 2411-03, 3211-04 CSA File No.: 012528 | 
| Catalog Notes | 
                                                Also tested according to AC-3e.
                                             | 
| Number of poles | 
                                                Three-pole
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Fitted with: | 
                                                Mirror contact
                                             | 
| Operating frequency | 
                                                5000 mechanical Operations/h (AC operated)
                                             | 
| Pollution degree | 
                                                3
                                             | 
| Climatic proofing | 
                                                Damp heat, constant, to IEC 60068-2-78  Damp heat, cyclic, to IEC 60068-2-30 | 
| Connection to SmartWire-DT | 
                                                No
                                             | 
| Rated impulse withstand voltage (Uimp) | 
                                                8000 V AC
                                             | 
| Utilization category | 
                                                AC-1: Non-inductive or slightly inductive loads, resistance furnaces  AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching | 
| Connection | 
                                                Push in terminals
                                             | 
| Frame size | 
                                                FS2
                                             | 
| Ambient operating temperature - max | 
                                                60 °C
                                             | 
| Ambient operating temperature - min | 
                                                -25 °C
                                             | 
| Ambient operating temperature (enclosed) - max | 
                                                40 °C
                                             | 
| Ambient operating temperature (enclosed) - min | 
                                                -25 °C
                                             | 
| Ambient storage temperature - max | 
                                                80 °C
                                             | 
| Ambient storage temperature - min | 
                                                -40 °C
                                             | 
| Assigned motor power at 115/120 V, 60 Hz, 1-phase | 
                                                0.25 HP
                                             | 
| Assigned motor power at 200/208 V, 60 Hz, 3-phase | 
                                                1.5 HP
                                             | 
| Assigned motor power at 230/240 V, 60 Hz, 1-phase | 
                                                1 HP
                                             | 
| Assigned motor power at 230/240 V, 60 Hz, 3-phase | 
                                                2 HP
                                             | 
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 
                                                3 HP
                                             | 
| Assigned motor power at 575/600 V, 60 Hz, 3-phase | 
                                                5 HP
                                             | 
| Conventional thermal current Ith (1-pole, enclosed) | 
                                                80 A
                                             | 
| Conventional thermal current Ith (3-pole, enclosed) | 
                                                32 A
                                             | 
| Conventional thermal current Ith at 55°C (3-pole, open) | 
                                                37 A
                                             | 
| Conventional thermal current Ith of main contacts (1-pole, open) | 
                                                88 A
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Application | 
                                                Contactors for Motors
                                             | 
| Product category | 
                                                Contactors
                                             | 
| Protection | 
                                                Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
                                             | 
| Arcing time | 
                                                10 ms
                                             | 
| Electrical connection type of main circuit | 
                                                Push-in connection
                                             | 
| Screwdriver size | 
                                                3.0 x 0.5 mm, Terminal screw  3 x 0.5 mm, Terminal screw | 
| Voltage type | 
                                                AC
                                             | 
| Degree of protection | 
                                                IP20
                                             | 
| Number of auxiliary contacts (normally closed contacts) | 
                                                1
                                             | 
| Number of auxiliary contacts (normally open contacts) | 
                                                1
                                             | 
| Number of contacts (normally closed contacts) | 
                                                1
                                             | 
| Number of contacts (normally closed) as main contact | 
                                                0
                                             | 
| Number of contacts (normally open contacts) | 
                                                1
                                             | 
| Number of main contacts (normally open contact) | 
                                                3
                                             | 
| Rated breaking capacity at 220/230 V | 
                                                70 A
                                             | 
| Rated breaking capacity at 380/400 V | 
                                                70 A
                                             | 
| Rated breaking capacity at 500 V | 
                                                50 A
                                             | 
| Rated breaking capacity at 660/690 V | 
                                                40 A
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                                230 V
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                                230 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                                240 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                                240 V
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Duty factor | 
                                                100 %
                                             | 
| Emitted interference | 
                                                According to EN 60947-1
                                             | 
| Interference immunity | 
                                                According to EN 60947-1
                                             | 
| Lifespan, mechanical | 
                                                10,000,000 Operations (AC operated)
                                             | 
| Pick-up voltage | 
                                                0.8 - 1.1 V AC x Uc
                                             | 
| Power consumption, pick-up, 50 Hz | 
                                                52 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
                                             | 
| Safe isolation | 
                                                400 V AC, Between the contacts, According to EN 61140  400 V AC, Between coil and contacts, According to EN 61140 | 
| Power consumption, pick-up, 60 Hz | 
                                                67 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
                                             | 
| Power consumption, sealing, 50 Hz | 
                                                2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz  7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz | 
| Power consumption, sealing, 60 Hz | 
                                                2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz  8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz | 
| Terminal capacity (flexible with unisolated ferrule) | 
                                                1 x (0.75 - 2.5) mm², Main cables  2 x (0.75 - 2.5) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.5 - 2.5) mm², Control circuit cables 2 x (0.5 - 2.5) mm², Control circuit cables 1 x (1 - 6) mm², Main cables 2 x (1 - 6) mm², Main cables | 
| Terminal capacity (flexible with ultrasonic welded cable end) | 
                                                1 x (0.75 - 2.5) mm², Main cables  2 x (0.75 - 2.5) mm², Main cables 1 x (0.75 - 2.5) mm², Control circuit cables 2 x (0.75 - 2.5) mm², Control circuit cables 1 x (0.5 - 2.5) mm², Control circuit cables 2 x (0.5 - 2.5) mm², Control circuit cables 1 x (1 - 10) mm², Main cables 2 x (1 - 6) mm², Main cables | 
| Terminal capacity (flexible with ferrule) | 
                                                1 x (0.75 - 2.5) mm²  2 x (0.75 - 2.5) mm² | 
| Shock resistance | 
                                                10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms  7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 6.5 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 8 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 2 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms | 
| Terminal capacity (solid) | 
                                                2 x (0.5 - 2.5) mm², Control circuit cables  2 x (1 - 6) mm² 1 x (0.5 - 0.25) mm² 1 x (1 - 6) mm² | 
| Terminal capacity (solid/stranded AWG) | 
                                                18 - 8, Main cables  20 - 14 | 
| Terminal capacity (flexible) | 
                                                1 x (0.5 - 2.5) mm²  1 x (1 - 10) mm² 2 x (1-6) mm² 2 x (0.5 - 2.5) mm² | 
| Rated insulation voltage (Ui) | 
                                                690 V
                                             | 
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 
                                                112 A
                                             | 
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 
                                                40 A
                                             | 
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 
                                                8 A
                                             | 
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 
                                                8 A
                                             | 
| Rated operational current (Ie) at AC-3, 440 V | 
                                                8 A
                                             | 
| Rated operational current (Ie) at AC-3, 500 V | 
                                                5 A
                                             | 
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 
                                                4 A
                                             | 
| Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 
                                                5 A
                                             | 
| Rated operational current (Ie) at AC-4, 400 V | 
                                                5 A
                                             | 
| Rated operational current (Ie) at AC-4, 440 V | 
                                                5 A
                                             | 
| Rated operational current (Ie) at AC-4, 500 V | 
                                                4.5 A
                                             | 
| Rated operational current (Ie) at AC-4, 660 V, 690 V | 
                                                4 A
                                             | 
| Rated operational power at AC-3, 240 V, 50 Hz | 
                                                2.2 kW
                                             | 
| Rated operational power at AC-3, 380/400 V, 50 Hz | 
                                                3 kW
                                             | 
| Rated operational power at AC-3, 415 V, 50 Hz | 
                                                3.9 kW
                                             | 
| Rated operational power at AC-4, 220/230 V, 50 Hz | 
                                                1 kW
                                             | 
| Rated operational power at AC-4, 240 V, 50 Hz | 
                                                1.5 kW
                                             | 
| Rated operational power at AC-4, 380/400 V, 50 Hz | 
                                                2.2 kW
                                             | 
| Rated operational power at AC-4, 415 V, 50 Hz | 
                                                2.3 kW
                                             | 
| Rated operational power at AC-4, 440 V, 50 Hz | 
                                                2.4 kW
                                             | 
| Rated operational power at AC-4, 500 V, 50 Hz | 
                                                2.5 kW
                                             | 
| Rated operational power at AC-4, 660/690 V, 50 Hz | 
                                                2.9 kW
                                             | 
| Rated operational power (NEMA) | 
                                                0 kW
                                             | 
| Rated operational voltage (Ue) at AC - max | 
                                                690 V
                                             | 
| Switching time (AC operated, make contacts, closing delay) - max | 
                                                22 ms
                                             | 
| Switching time (AC operated, make contacts, closing delay) - min | 
                                                16 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - max | 
                                                14 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - min | 
                                                8 ms
                                             | 
| Short-circuit current rating (basic rating) | 
                                                5 kA, 125 A max. fuse CLASS RK5, SCCR (UL/CSA)  5 kA, 125 A max. CB, SCCR (UL/CSA) | 
| Short-circuit current rating (high fault at 480 V) | 
                                                100 kA, 70 A CLASS J max. fuse, SCCR (UL/CSA)  30 kA, 30 A CLASS RK5, SCCR (UL/CSA) 65 kA, 32 A max. CB, SCCR (UL/CSA) | 
| Short-circuit current rating (high fault at 600 V) | 
                                                100 kA, 70 A CLASS J max. fuse, SCCR (UL/CSA)  30 kA, 30 A CLASS RK5, SCCR (UL/CSA) | 
| Suitable for | 
                                                Also motors with efficiency class IE3
                                             | 
| Operating voltage at AC, 50 Hz - min | 
                                                24 V
                                             | 
| Operating voltage at AC, 50 Hz - max | 
                                                690 V
                                             | 
| Operating voltage at AC, 60 Hz - min | 
                                                24 V
                                             | 
| Operating voltage at AC, 60 Hz - max | 
                                                690 V
                                             |