Eaton Moeller® series PKE Function element for connecting interface to Modbus RTU
| Product Name |
Eaton Moeller® series PKE Function element
|
| Catalog Number |
199344
|
| Product Length/Depth |
75 mm
|
| Product Height |
65 mm
|
| Product Width |
67.5 mm
|
| Product Weight |
0.032 kg
|
| Certifications |
CSA File No.: 165628
IEC/EN 61131-2 UL File No.: E36332 UL Category Control No.: NKCR |
| Catalog Notes |
Messages: Display of All phase currents in % - Display of Contactor state PKE - Display of Part no. of trip block - Display of Set short-circuit release value - Display of Set value of overload releases - Display of Thermal load as a % - Display of Trip indications (Overload, Short-circuit,...) - Commands: Remote disconnection of motor-protective circuit-breaker
|
| Used with |
Brightlayer
|
| Type |
Modbus RTU PKE module
|
| Air discharge |
8 kV, according to IEC 61131-2, level 3, ESD
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| Fitted with: |
Potential separation
|
| Pollution degree |
2
|
| Burst impulse |
1 kV, Signal cable
|
| Category (EN 954-1) |
B
|
| Explosion safety category for dust |
None
|
| Environmental conditions |
Condensation: prevent with appropriate measures
|
| Explosion safety category for gas |
None
|
| Voltage type |
DC
|
| Mounting position |
As PKE12/35/65
|
| Overvoltage category |
II
|
| Constant acceleration |
1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations
|
| Constant amplitude |
3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-30 °C
|
| Height of fall (IEC/EN 60068-2-32) - max |
0.3 m
|
| Electromagnetic fields |
1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008)
3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008) |
| Number of HW-interfaces CAN |
0
|
| Radiated RFI |
10 V (IEC/EN 61131-2:2008, Level 3)
|
| Drop and topple |
50 mm Drop height, Drop to IEC/EN 60068-2-31
|
| Radio interference class |
Class A (EN 55011)
|
| Relative humidity |
5 - 95 % (non-condensing, IEC/EN 60068-2-30)
|
| Degree of protection |
IP20
|
| Protocol |
MODBUS
|
| Shock resistance |
15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
|
| System accessory |
Yes
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
0
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
1
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Static heat dissipation, non-current-dependent Pvs |
0.5 W
|
| Supply voltage at AC, 50 Hz - max |
0 V
|
| Supply voltage at AC, 50 Hz - min |
0 V
|
| Supply voltage at AC, 60 Hz - max |
0 V
|
| Supply voltage at AC, 60 Hz - min |
0 V
|
| Supply voltage at DC - max |
15 V
|
| Supply voltage at DC - min |
15 V
|