Eaton DC1 Variable frequency drive, 230 V AC, 3-phase, 7 A, 1.5 kW, IP66/NEMA 4X, Radio interference suppression filter, 7-digital display assembly, Local controls, Additional PCB protection, UV resistant, FS1
| Product Name |
Eaton DC1 Variable frequency drive
|
| Catalog Number |
199416
|
| Product Length/Depth |
162 mm
|
| Product Height |
232 mm
|
| Product Width |
161 mm
|
| Product Weight |
2.5 kg
|
| Certifications |
CUL
RCM UL EAC UL File No.: E172143 Certified by UL for use in Canada CE UkrSEPRO IEC/EN61800-5 UL 508C CE marking IEC/EN 61800-3 UL report applies to both US and Canada IEC/EN 61800-2 CSA-C22.2 No. 14 UL Listed IEC/EN 61800-5-1 RoHS, ISO 9001 UL Category Control No.: NMMS, NMMS7 |
| Catalog Notes |
|
| Features |
Parameterization: drivesConnect mobile (App)
Parameterization: Keypad Parameterization: Fieldbus Parameterization: drivesConnect |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Fitted with: |
Local controls
Internal DC link PC connection Radio interference suppression filter Control unit 7-digital display assembly IGBT inverter UV resistance Additional PCB protection |
| Climatic proofing |
< 95 average relative humidity (RH), no condensation, no corrosion
|
| Connection to SmartWire-DT |
No
|
| Operating mode |
Sensorless vector control (SLV)
BLDC motors U/f control Synchronous reluctance motors PM motors Speed control with slip compensation |
| Rated impulse withstand voltage (Uimp) |
2000 V
|
| Frame size |
FS1
|
| Altitude |
Max. 4000 m
Above 1000 m with 1 % derating per 100 m |
| Application in domestic and commercial area permitted |
Yes
|
| Mains switch-on frequency |
Maximum of one time every 30 seconds
|
| Ambient operating temperature - max |
40 °C
|
| Ambient operating temperature - min |
-20 °C
|
| Mains voltage - max |
240 V
|
| Output voltage - max |
250 V
|
| Rated operational power at 220/230 V, 50 Hz, 3-phase |
1.5 kW
|
| Relative symmetric net frequency tolerance |
10 %
|
| Relative symmetric net voltage tolerance |
10 %
|
| Ambient storage temperature - max |
60 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Apparent power at 230 V |
2.79 kVA
|
| Apparent power at 240 V |
2.91 kVA
|
| Application in industrial area permitted |
Yes
|
| Product category |
Variable frequency drives
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
|
| Resolution |
0.1 Hz (Frequency resolution, setpoint value)
|
| Voltage rating - max |
240 V
|
| Mounting position |
Vertical
|
| Overvoltage category |
III
|
| Communication interface |
CANopen®, built in
OP-Bus (RS485), built in SmartWire-DT, optional Modbus RTU, built in |
| Converter type |
U converter
|
| Degree of protection |
IP66
NEMA 4X |
| Assigned motor power at 220/230 V, 60 Hz, 3-phase |
2 HP
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Input current ILN at 150% overload |
9.5 A
|
| Mains current distortion |
120 %
|
| Assigned motor current IM at 220 - 240 V, 60 Hz, 150% overload |
6.8 A
|
| Assigned motor current IM at 230 V, 50 Hz, 150% overload |
6.3 A
|
| Protocol |
MODBUS
CAN Other bus systems EtherNet/IP |
| Overload current IL at 150% overload |
10.5 A
|
| Rated frequency - max |
62 Hz
|
| Rated frequency - min |
48 Hz
|
| Rated operational power at 380/400 V, 50 Hz, 3-phase |
0.75 kW
|
| System configuration type |
AC supply systems with earthed center point
|
| Braking current |
≤ 0.6 A (max. 6 A for 120 ms), Actuator for external motor brake
|
| Electromagnetic compatibility |
1st and 2nd environments (according to EN 61800-3)
|
| Braking torque |
Max. 30 % MN, Standard - Main circuit
Max. 100 % of rated operational current Ie, variable, DC - Main circuit |
| Cable length |
75 m, unscreened, maximum permissible, Motor feeder
150 m, unscreened, with motor choke, maximum permissible, Motor feeder 50 m, screened, maximum permissible, Motor feeder 100 m, screened, with motor choke, maximum permissible, Motor feeder |
| Output voltage (U2) |
230 V AC, 3-phase
240 V AC, 3-phase |
| Delay time |
< 10 ms, On-delay
< 10 ms, Off-delay |
| Number of inputs (analog) |
2 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)
|
| Number of inputs (digital) |
4 (parameterizable, 10 - 30 V DC)
|
| Radio interference class |
C2, C3: depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.
Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments |
| Number of outputs (digital) |
1
|
| Starting current - max |
175 % IH
|
| Number of phases (input) |
3
|
| Number of relay outputs |
1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
|
| Number of phases (output) |
3
|
| Power consumption |
61.5 W
|
| Rated control supply voltage |
10 V DC (Us, max. 10 mA)
|
| Efficiency |
97 % (η)
|
| Supply frequency |
50/60 Hz
|
| Leakage current at ground IPE - max |
7.5 mA
|
| Mains voltage - min |
200 V
|
| Nominal output current I2N |
7 A
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
0
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
0
|
| Number of HW-interfaces (RS-422) |
0
|
| Number of HW-interfaces (RS-485) |
1
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Number of outputs (analog) |
1
|
| Output at linear load at rated output voltage - max |
1.5 kW
|
| Output at quadratic load at rated output voltage - max |
1.5 kW
|
| Output frequency - max |
500 Hz
|
| Output frequency - min |
0 Hz
|
| Short-circuit protection (external output circuits) |
Type 1 coordination via the power bus' feeder unit, Main circuit
|
| Suitable for |
Branch circuits, (UL/CSA)
|
| Switching frequency |
8 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
|
| Rated operational current (Ie) |
7 A at 150% overload (at an operating frequency of 6 kHz and an ambient air temperature of +40 °C)
|
| Rated operational voltage |
240 V AC, 3-phase
230 V AC, 3-phase |
| Short-circuit protection rating |
10 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
|
| Heat dissipation at current/speed |
37 W at 25% current and 0% speed
37 W at 25% current and 50% speed 44 W at 50% current and 0% speed 48 W at 50% current and 50% speed 54 W at 50% current and 90% speed 58 W at 100% current and 0% speed 69 W at 100% current and 50% speed 81 W at 100% current and 90% speed |