Eaton Moeller® series M22 Shroud, for flush mounting plate, 4 mounting locations
| Product Name |
Eaton Moeller® series M22 Accessory Shroud
|
| Catalog Number |
216551
|
| Product Length/Depth |
110 mm
|
| Product Height |
80 mm
|
| Product Width |
105 mm
|
| Product Weight |
0.181 kg
|
| Compliances |
Bureau Veritas
CE Marked GoST-R |
| Certifications |
CSA Certified
CCC Marked Lloyd's Register Certified CE CSA Class No.: 3211-03 UL 508 CSA-C22.2 No. 14-05 IEC/EN 60947-5 CSA File No.: 012528 CSA-C22.2 No. 94-91 UL CSA UL File No.: E29184 UL Category Control No.: NKCR |
| Type |
Four-element
|
| 10.10 Temperature rise |
Not applicable.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Please enquire
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Connection to SmartWire-DT |
No
|
| Series |
M22
|
| Color |
Gray
|
| Material |
Insulated material light
|
| Degree of protection |
NEMA 12
IP40 |
| Knockouts |
4 x M20 (cable entry knockouts at the base)
|
| Ambient operating temperature - max |
70 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Force for positive opening - min |
0 N
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Environmental rating |
IP66, NEMA 4X, NEMA 13
|
| Number of appliances to build in |
4
|
| Number of locations |
4
|
| RAL-number |
7035
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Static heat dissipation, non-current-dependent Pvs |
0 W
|
| Protection |
Protection type only in combination with flush mounting plates M22-E…
|
| Size |
22.5 mm
|