照片为代表
                                
                                
                                    
                                    Download
                                
                                
                                Eaton Moeller series NZM - Molded Case Circuit Breaker. Remote operator, 220-250VDC, for size 3
| Product Name | 
                                            
                                            
                                             
                                                Eaton Moeller series NZM remote operator
                                             
                                         | 
                                    
| Catalog Number | 
                                            
                                            
                                             
                                                259860
                                             
                                         | 
                                    
| Product Length/Depth | 
                                            
                                            
                                             
                                                170 mm
                                             
                                         | 
                                    
| Product Height | 
                                            
                                            
                                             
                                                140 mm
                                             
                                         | 
                                    
| Product Width | 
                                            
                                            
                                             
                                                140 mm
                                             
                                         | 
                                    
| Product Weight | 
                                            
                                            
                                             
                                                3.194 kg
                                             
                                         | 
                                    
| Compliances | 
                                            
                                            
                                             
                                                IEC  
                                        UL/CSA RoHS conform  | 
                                    
| Certifications | 
                                            
                                            
                                             
                                                CSA (Class No. 1437-01)  
                                        UL (File No. E140305) CE marking UL listed CSA (File No. 22086) CSA certified UL (Category Control Number DIHS) IEC60947 CSA-C22.2 No. 5-09 UL489  | 
                                    
| Used with | 
                                            
                                            
                                             
                                                N(S)3(-4)  
                                        NZM3(-4)  | 
                                    
| Voltage rating | 
                                            
                                            
                                             
                                                220 - 250 V DC
                                             
                                         | 
                                    
| 10.10 Temperature rise | 
                                            
                                            
                                             
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             
                                         | 
                                    
| 10.11 Short-circuit rating | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.12 Electromagnetic compatibility | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             
                                         | 
                                    
| 10.13 Mechanical function | 
                                            
                                            
                                             
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             
                                         | 
                                    
| 10.2.2 Corrosion resistance | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.2.5 Lifting | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.6 Mechanical impact | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.2.7 Inscriptions | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.3 Degree of protection of assemblies | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.4 Clearances and creepage distances | 
                                            
                                            
                                             
                                                Meets the product standard's requirements.
                                             
                                         | 
                                    
| 10.5 Protection against electric shock | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.6 Incorporation of switching devices and components | 
                                            
                                            
                                             
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             
                                         | 
                                    
| 10.7 Internal electrical circuits and connections | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.8 Connections for external conductors | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.2 Power-frequency electric strength | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.3 Impulse withstand voltage | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| 10.9.4 Testing of enclosures made of insulating material | 
                                            
                                            
                                             
                                                Is the panel builder's responsibility.
                                             
                                         | 
                                    
| Frame | 
                                            
                                            
                                             
                                                NZM3
                                             
                                         | 
                                    
| Lifespan, mechanical | 
                                            
                                            
                                             
                                                15000 operations
                                             
                                         | 
                                    
| Breaking time | 
                                            
                                            
                                             
                                                1000 ms
                                             
                                         | 
                                    
| Closing delay | 
                                            
                                            
                                             
                                                80 ms
                                             
                                         | 
                                    
| Voltage type | 
                                            
                                            
                                             
                                                AC
                                             
                                         | 
                                    
| Number of poles | 
                                            
                                            
                                             
                                                Three-pole/Four-pole
                                             
                                         | 
                                    
| Number of operations per hour - max | 
                                            
                                            
                                             
                                                60
                                             
                                         | 
                                    
| Voltage tolerance - max | 
                                            
                                            
                                             
                                                1.1
                                             
                                         | 
                                    
| Voltage tolerance - min | 
                                            
                                            
                                             
                                                0.85
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                            
                                            
                                             
                                                0 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - max | 
                                            
                                            
                                             
                                                250 V
                                             
                                         | 
                                    
| Rated control supply voltage (Us) at DC - min | 
                                            
                                            
                                             
                                                220 V
                                             
                                         | 
                                    
| Signal duration of remote operator at switch off - min | 
                                            
                                            
                                             
                                                250 ms
                                             
                                         | 
                                    
| Signal duration of remote operator at switch on - min | 
                                            
                                            
                                             
                                                30 ms
                                             
                                         | 
                                    
| Switch drive type | 
                                            
                                            
                                             
                                                Motor drive
                                             
                                         | 
                                    
| Terminal capacity (solid/flexible conductor) | 
                                            
                                            
                                             
                                                18 - 14 AWG  
                                        0.75 mm² - 2.5 mm² with ferrule  | 
                                    
| Type | 
                                            
                                            
                                             
                                                Accessory
Remote operator, can be synchronized
                                             
                                         | 
                                    
| Special features | 
                                            
                                            
                                             
                                                Cannot be combined with switch-disconnector PN...
M22-CK11(20/02) dual auxiliary switch cannot be combined with NZM3-XR… remote operator
                                             
                                         | 
                                    
| Operating voltage - max | 
                                            
                                            
                                             
                                                1.1 x Us
                                             
                                         | 
                                    
| Operating voltage - min | 
                                            
                                            
                                             
                                                0.85 x Us
                                             
                                         | 
                                    
| Power consumption | 
                                            
                                            
                                             
                                                250 W (24 - 30 V DC)
                                             
                                         |