照片为代表
Download
Eaton Moeller series NZM - Molded Case Circuit Breaker. Clip plate, for size 1
Product Name |
Eaton Moeller series NZM operating element accessory
|
Catalog Number |
260213
|
Product Length/Depth |
20 mm
|
Product Height |
158 mm
|
Product Width |
90 mm
|
Product Weight |
0.152 kg
|
Compliances |
RoHS conform
|
Certifications |
CSA (Class No. 1437-01)
CSA-C22.2 No. 5-09 North America (UL listed, CSA certified) UL (File No. E140305) CSA (File No. 22086) CE marking UL489 UL/CSA IEC IEC60947 UL (Category Control Number DIHS) |
Used with |
General accessories
NZM1(-4) PN1(-4) N(S)1(-4) |
Special features |
Enables clip-on of switch onto DIN rails
|
Type |
Accessory
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Frame |
NZM1
|
Degree of protection |
UL489; CSA-C22.2 No. 5-09; IEC60947, CE marking
|
Fastening type |
DIN rail (top hat rail) 35 mm
|
DIN-rail adapter type |
Straight
|
Material |
Metal
|