Eaton Moeller® series ETR2 Timing relay, 0.05s-100h, 24-240VAC 50/60Hz, 24-48VDC, 1W, flashing, 2 times
| Product Name |
Eaton Moeller® series ETR2 Timing relay
|
| Catalog Number |
262730
|
| Product Length/Depth |
63 mm
|
| Product Height |
70 mm
|
| Product Width |
17.5 mm
|
| Product Weight |
0.053 kg
|
| Certifications |
CSA File No.: UL report valid
UL CSA-22.2 No. 14 IEC/EN 61812-1 UL 508 CE UL Category Control No.: NKCR, NKCR7 IEC/EN 60947-5-1 UL File No.: E29184 Certified by UL for use in Canada CSA Class No.: 3211-03 |
| Catalog Notes |
Package quantity 1
|
| Used with |
XC100, XC121, XC200
|
| Type |
Timer relay
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Screw connection
|
| Rated operational current (Ie) |
4 A at AC-15, 220 V 230 V 240 V
3 A at 230 V (NC) 3 A at 230 V (NO) |
| Ambient operating temperature - max |
60 °C
|
| Ambient operating temperature - min |
-25 °C
|
| Heat dissipation capacity Pdiss |
0 W
|
| Nominal current |
3 A
|
| Degree of protection |
IP20
|
| Functions |
Clock function, starting with pulse, variable
Remote operation possible Flashing, pulse initiating Fixed timing function Flashing, starting with pulse, fixed time Clock function, starting with pause, variable Flashing, starting with pause, fixed time Flashing, pause initiating Pulse and pause times independently adjustable |
| Mains voltage tolerance |
24 - 48 V DC
24 - 240 V AC (at 50/60 Hz) |
| Voltage type |
AC/DC
|
| Suitable for |
DIN rail (top hat rail) mounting
|
| Number of contacts (change-over contacts) |
1
|
| Number of outputs (delayed, change-over contact) |
0
|
| Number of outputs (delayed, normally closed contact) |
0
|
| Number of outputs (delayed, normally open contact) |
0
|
| Number of outputs (undelayed, change-over contact) |
0
|
| Number of outputs (undelayed, normally closed contact) |
0
|
| Number of outputs (undelayed, normally open contact) |
0
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
24 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - min |
24 V
|
| Rated control supply voltage (Us) at DC - max |
240 V
|
| Rated control supply voltage (Us) at DC - min |
24 V
|
| Time range - max |
360000 s
|
| Time range - min |
0.05 s
|
| Width in number of modular spacings |
1
|
| Product category |
ETR2 timing relays
|
| Voltage type of operating voltage |
AC/DC
|
| Operating voltage at AC, 50 Hz - min |
24 V
|
| Operating voltage at AC, 50 Hz - max |
240 V
|
| Operating voltage at AC, 60 Hz - min |
24 V
|
| Operating voltage at AC, 60 Hz - max |
240 V
|
| Operating voltage at DC - min |
24 V
|
| Operating voltage at DC - max |
48 V
|