Eaton XIOC Communication module for XC100/200, 24 V DC, serial, modbus, SUCOM-A, suconet K
| Product Name |
Eaton XIOC Communication module
|
| Catalog Number |
267191
|
| Product Length/Depth |
100 mm
|
| Product Height |
95 mm
|
| Product Width |
30 mm
|
| Product Weight |
0.145 kg
|
| Certifications |
CSA File No.: 012528
UL File No.: E135462 CSA Class No.: 2252-01 UL CSA UL Category Control No.: NRAQ CSA-C22.2 No. 142-M IEC/EN 61131-2 CSA-C22.2 No. 0-M CE UL508 EN 50178 |
| Used with |
XC100/200 (expandable with up to 15 XI/OC modules)
|
| Type |
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Cable type |
RTS, CTS, DTR, DSR, DCD
|
| Pollution degree |
2
|
| Addressing |
Address range: 2 - 31
|
| Bus termination |
Switchable for RS485, RS422
|
| Explosion safety category for dust |
None
|
| Explosion safety category for gas |
None
|
| Character formats |
8E1, 8O1, 8N1, 8N2, 7E2, 7O2, 7N2, 7E1
|
| Overvoltage category |
II
|
| Supply voltage |
20.4 – 28.8 (11.8 – 14.4) V DC, Admissible range, Power supply
|
| Emitted interference |
Class A (according to DIN/EN 55011/22)
|
| Safety performance level (EN ISO 13849-1) |
None
|
| SIL (IEC 61508) |
None
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
0 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-20 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Number of slots |
As required
|
| Terminals |
Optionally, screw terminals or spring-loaded terminals for digital/analog modules
|
| Connection type |
9-pole SUB-D connector (male), RS232
6-pole spring-loaded terminal block, RS422/RS485 |
| Protection class |
1
|
| Number of modules |
2 (XC100)
4 (XC200) |
| Current consumption |
275 mA (Ie), Interfaces
275 mA, max. internal current consumption, Interface modules |
| Data transfer rate |
0.3 kBit/s, Interface, Transparent mode
2.4 kBit/s, Interface, Transparent mode 4.8 kBit/s, Interface, Transparent mode 9.6 kBit/s, Interface, Transparent mode 0.6 kBit/s, Interface, Transparent mode 250 Byte per slave, Transmit/receive data 187.5 kBit/s, 375 kBit/s (Suconet) 38.4 kBit/s, Interface, Transparent mode 0.3 - 57.6 kBit/s 1.2 kBit/s, Interface, Transparent mode 120 Byte per slave (Suconet-K slave), Transmit/receive data 19.2 kBit/s, Interface, Transparent mode 57.6 kBit/s, Interface, Transparent mode 187.5 or 375 kBit/s, Suconet-K slave |
| Degree of protection |
IP20
|
| Protocol |
MODBUS
Other bus systems RS485 (Interface) SUCONET |
| Residual ripple |
≤ 5 %
|
| Rapid counter inputs |
250 bytes per Com
|
| Resistance |
500 g/⌀ 50 mm ±25 g (impact resistance)
|
| Data transmission type |
Serial
|
| Vibration resistance |
57 - 150 Hz ± 1.0 mm
10 - 57 Hz, ± 0.075 mm |
| Shock resistance |
15 g, Mechanical, Shock duration 11 ms
|
| Transmission rate |
375 kBit/s
|
| Interfaces |
Number of active interfaces/modules: 1
RTS, CTS, DTR, DSR, DCD (Operating mode Transparent mode, Control and signal cables, Analog control inputs) RS485 RS422 RS232(C), RS422, RS485 (built-in) |
| Number of bytes |
250 bytes (per Com)
|
| Potential isolation |
Interfaces (RS485, RS422): yes
|
| Power loss |
6.6 W
|
| Voltage dips |
10 ms
|
| Number of HW-interfaces (industrial ethernet) |
0
|
| Number of HW-interfaces (other) |
0
|
| Number of HW-interfaces (parallel) |
0
|
| Number of HW-interfaces (RS-232) |
1
|
| Number of HW-interfaces (RS-422) |
1
|
| Number of HW-interfaces (RS-485) |
1
|
| Number of HW-interfaces (serial TTY) |
0
|
| Number of HW-interfaces (USB) |
0
|
| Number of HW-interfaces (wireless) |
0
|
| Number of interfaces (PROFINET) |
0
|
| Rated operational voltage |
24 (12) V DC
|
| Plug type |
RS485, 422: plug terminal block
RS232: 9 pole SUB-D plug |
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Repetition rate |
1 s
|
| Static heat dissipation, non-current-dependent Pvs |
6.6 W
|