Eaton Moeller® series DILM Replacement coil, 220 V 50 Hz, 240 V 60 Hz, AC operation, For use with: DILM250-S, DILM300A-S
Product Name |
Eaton Moeller® series DILM replacement coil
|
Catalog Number |
274202
|
Product Length/Depth |
100 mm
|
Product Height |
175 mm
|
Product Width |
135 mm
|
Product Weight |
1.19 kg
|
Compliances |
CE Marked
|
Certifications |
CSA Std. C22.2 No. 14-05
UL 508 IEC 60947-4-1 EN 60947-4-1 UL File No.: E29096 CSA-C22.2 No. 14-05 CE CSA CSA File No.: 1017510 CSA Class No.: 3211-04 IEC/EN 60947-4-1 UL UL Category Control No.: NLDX |
Used with |
DILM185-S/225-S/250
|
Accessories |
Individual coils
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Frequency rating |
50-60 Hz
|
Voltage type |
AC
|
Ambient operating temperature - max |
60 °C
|
Ambient operating temperature - min |
-40 °C
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
220 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
240 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
220 V
|
Rated control supply voltage (Us) at DC - max |
0 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Product category |
Accessories
|