Eaton Moeller® series DILA Contactor relay, 42 V 50/60 Hz, 2 N/O, 2 NC, Screw terminals, AC operation
| Product Name | 
                                                Eaton Moeller® series DILA Control relay
                                             | 
| Catalog Number | 
                                                276404
                                             | 
| Product Length/Depth | 
                                                75 mm
                                             | 
| Product Height | 
                                                68 mm
                                             | 
| Product Width | 
                                                45 mm
                                             | 
| Product Weight | 
                                                0.237 kg
                                             | 
| Compliances | 
                                                CE Marked
                                             | 
| Certifications | 
                                                IEC 60947-4-1  EN 60947-4-1 CSA Std. C22.2 No. 14-05 UL 508 VDE CE UL Category Control No.: NKCR UL File No.: E29184 EN 60947-5-1 UL CSA File No.: 012528 CSA IEC/EN 60947 CSA Class No.: 3211-03 CSA-C22.2 No. 14-05 IEC/EN 60947-4-1 VDE 0660 | 
| Features | 
                                                Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Fitted with: | 
                                                Positive operation contacts
                                             | 
| Operating frequency | 
                                                9000 Operations/h
                                             | 
| Pollution degree | 
                                                3
                                             | 
| Climatic proofing | 
                                                Damp heat, cyclic, to IEC 60068-2-30  Damp heat, constant, to IEC 60068-2-78 | 
| Ambient operating temperature - max | 
                                                60 °C
                                             | 
| Ambient operating temperature - min | 
                                                -25 °C
                                             | 
| Ambient operating temperature (enclosed) - max | 
                                                40 °C
                                             | 
| Ambient operating temperature (enclosed) - min | 
                                                25 °C
                                             | 
| Ambient storage temperature - max | 
                                                80 °C
                                             | 
| Ambient storage temperature - min | 
                                                40 °C
                                             | 
| Equipment heat dissipation, current-dependent Pvid | 
                                                0 W
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Heat dissipation per pole, current-dependent Pvid | 
                                                0.5 W
                                             | 
| Number of auxiliary contacts (change-over contacts) | 
                                                0
                                             | 
| Number of auxiliary contacts (normally closed contacts) | 
                                                2
                                             | 
| Number of auxiliary contacts (normally closed contacts, delayed switching) | 
                                                0
                                             | 
| Number of auxiliary contacts (normally open contacts) | 
                                                2
                                             | 
| Number of auxiliary contacts (normally open contacts, leading) | 
                                                0
                                             | 
| Number of contacts (normally closed contacts) | 
                                                2
                                             | 
| Number of contacts (normally open contacts) | 
                                                2
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                                42 V
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                                42 V
                                             | 
| Connection to SmartWire-DT | 
                                                No
                                             | 
| Rated impulse withstand voltage (Uimp) | 
                                                6000 V AC
                                             | 
| Connection | 
                                                Screw terminals
                                             | 
| Application | 
                                                Contactor relays
                                             | 
| Product category | 
                                                DILA relays
                                             | 
| Protection | 
                                                Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
                                             | 
| Conventional thermal current Ith at 60°C (3-pole, open) | 
                                                16 A
                                             | 
| Voltage type of operating voltage | 
                                                AC/DC
                                             | 
| Rated switch current | 
                                                16 A
                                             | 
| Operating voltage at AC, 50 Hz - min | 
                                                17 V
                                             | 
| Operating voltage at AC, 50 Hz - max | 
                                                500 V
                                             | 
| Operating voltage at AC, 60 Hz - min | 
                                                17 V
                                             | 
| Operating voltage at AC, 60 Hz - max | 
                                                500 V
                                             | 
| Operating voltage at DC - min | 
                                                24 VDC
                                             | 
| Operating voltage at DC - max | 
                                                220 VDC
                                             | 
| Screwdriver size | 
                                                0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver  2, Terminal screw, Pozidriv screwdriver | 
| Voltage type | 
                                                AC
                                             | 
| Code number | 
                                                22D
                                             | 
| Degree of protection | 
                                                IP20
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Control circuit reliability | 
                                                λ < 5 x 10-7 (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)  λ < 5 x 1/10⁷ (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA) | 
| Connection type (auxiliary circuit) | 
                                                Screw connection
                                             | 
| Duty factor | 
                                                100 %
                                             | 
| Lifespan, mechanical | 
                                                20,000,000 Operations (AC operated)
                                             | 
| Mounting method | 
                                                Screw
                                             | 
| Pick-up voltage | 
                                                0.8 - 1.1 V AC x Uc (voltage tolerance - dual frequency coil 50/60 Hz)
                                             | 
| Safe isolation | 
                                                400 V AC, Between coil and auxiliary contacts, According to EN 61140  400 V AC, Between auxiliary contacts, According to EN 61140 | 
| Power consumption, pick-up, 60 Hz | 
                                                27 VA, AC, Dual-frequency coil at 60 Hz  25 VA, AC, Dual-frequency coil at 60 Hz | 
| Screw size | 
                                                M3.5, Terminal screw
                                             | 
| Power consumption, sealing, 60 Hz | 
                                                1.4 W, Dual-frequency coil in a cold state and 1.0 x Us  4.2 VA, Dual-frequency coil in a cold state and 1.0 x Us 3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us | 
| Rated operational current (Ie) | 
                                                6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series)  10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series) 5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series) 10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series) 6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series) 3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series) 1 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series) 4 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series) 1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series) 4 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series) 2 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series) 16 A | 
| Power consumption, sealing, 50 Hz | 
                                                1.4 W, Dual-frequency coil in a cold state and 1.0 x Us  3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us 4.2 VA, Dual-frequency coil in a cold state and 1.0 x Us | 
| Switching capacity (auxiliary contacts, general use) | 
                                                15 A, 600 V AC, (UL/CSA)  1 A, 250 V DC, (UL/CSA) | 
| Switching capacity (auxiliary contacts, pilot duty) | 
                                                P300, DC operated (UL/CSA)  A600, AC operated (UL/CSA) | 
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                                42 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                                42 V
                                             | 
| Rated insulation voltage (Ui) | 
                                                690 V
                                             | 
| Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V | 
                                                4 A
                                             | 
| Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V | 
                                                4 A
                                             | 
| Rated operational current (Ie) at AC-15, 500 V | 
                                                1.5 A
                                             | 
| Rated operational current for specified heat dissipation (In) | 
                                                15.5 A
                                             | 
| Rated operational voltage (Ue) at AC - max | 
                                                690 V
                                             | 
| Static heat dissipation, non-current-dependent Pvs | 
                                                1.4 W
                                             | 
| Stripping length (main cable) | 
                                                10 mm
                                             | 
| Switching time (AC operated, make contacts, closing delay) - max | 
                                                21 ms
                                             | 
| Switching time (AC operated, make contacts, closing delay) - min | 
                                                15 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - max | 
                                                18 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - min | 
                                                9 ms
                                             | 
| Terminal capacity (flexible with ferrule) | 
                                                1 x (0.75 - 2.5) mm², Screw terminals  2 x (0.75 - 2.5) mm², Screw terminals | 
| Shock resistance | 
                                                5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms  7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms | 
| Terminal capacity (solid/stranded AWG) | 
                                                18 - 14, Screw terminals
                                             | 
| Short-circuit protection rating without welding | 
                                                10 A gG/gL, 500 V, Max. Fuse, Contacts
                                             | 
| Terminal capacity (solid) | 
                                                1 x (0.75 - 4) mm², Screw terminals  2 x (0.75 - 2.5) mm², Screw terminals | 
| Tightening torque | 
                                                1.2 Nm, Screw terminals
                                             | 
| Actuating voltage | 
                                                42 V 50/60 Hz
                                             |