照片为代表
Download
Eaton DX radio interference suppression filter, Single-phase, low leakage current, ULN= max. 250 + 10% V, 8 A, For use with: DE1, DC1, DA1, DG1, DM1
Product Name |
Eaton DX Radio interference suppression filter - superlow
|
Catalog Number |
EP-400103
|
Product Length/Depth |
160 mm
|
Product Height |
75 mm
|
Product Width |
38 mm
|
Product Weight |
0.58 kg
|
Certifications |
EN 50178
IEC/EN 61800-3 |
Catalog Notes |
super low leakage current
|
Used with |
DC1
DE1 DM1 DA1 DG1 |
Product Category |
Accessories
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Accessory/spare part type |
Filter
|
Altitude |
Max. 1000 m
At higher altitudes observe derating |
Ambient operating temperature - max |
50 °C
|
Ambient operating temperature - min |
-25 °C
|
Number of phases |
1
|
Mains voltage tolerance |
Max. 250 V (+10 %)
|
Connection type |
Screw terminals
|
Degree of protection |
IP20
|
Mounting method |
Separate mounting
|
Rated operational current (Ie) - max |
8 A
|
Rated operational current for specified heat dissipation (In) |
8 A
|
Static heat dissipation, non-current-dependent Pvs |
0 W
|