Eaton PSG Power supply unit, Three-phase, 320 - 575 V AC / 24 V DC, 10 A, 240 W
Product Name |
Eaton PSG power supply unit
|
Catalog Number |
EP-401399
|
UPC |
786689860738
|
Product Length/Depth |
124 mm
|
Product Height |
125.3 mm
|
Product Width |
50 mm
|
Product Weight |
0.84 kg
|
Certifications |
IEC 62368-1
EN 61010-1 EN 61010-2-201: 2018 EN 55032 EN 61000-3-2 EN 61000-3-3 CISPR 35/EN 55035 EN 61000-4-12: 2017 EN 61000-6-1: 2007 EN 61000-6-3 IEC/EN 61204-3 EN IEC 63000 RoHS conform REACH TSCA P65 SELV (EN 60950) CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2006/95/EC BS EN 62368-1 UL 62368-1 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC 61000-4-4 IEC 61000-4-5 IEC 61000-4-6 IEC 61000-4-8: 2010 EN 61000-4-11 CSA C22.2 No. 61010-2-201 UL 61010-2-201 |
Catalog Notes |
|
Power consumption |
268 W
|
Phase |
Three-phase
|
Nominal Output Voltage 1 |
24 V
|
Nominal Output Voltage 2 |
0 V
|
Nominal Output Voltage 3 |
0 V
|
Voltage type (supply voltage) |
AC
|
Features |
Output voltage stabilized
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Meets the product standard's requirements.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Screw connection
|
Fitted with: |
Not accessible internal input fuse (T3.15 AH/500 V, 600 V) for device protection
|
Pollution degree |
2
|
Mounting Method |
Rail mounting possible
|
Climatic proofing |
< 95 % relative humidity at +25 °C, no condensation
|
Enclosure material |
Aluminum
|
Altitude |
Max. 2000 m
|
Output voltage |
24 V
|
Degree of Protection |
IP20
NEMA Other |
Output voltage at DC - min |
24 V
|
Rated frequency - max |
63 Hz
|
Rated frequency - min |
47 Hz
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Rated output power |
240 W
|
Supply voltage at AC, 50 Hz - max |
575 VAC
|
Supply voltage at AC, 50 Hz - min |
320 VAC
|
Supply voltage at AC, 60 Hz - max |
575 VAC
|
Supply voltage at AC, 60 Hz - min |
320 VAC
|
Supply voltage at DC - max |
800 VDC
|
Supply voltage at DC - min |
450 VDC
|
Width in number of modular spacings |
2.8
|
Product category |
Power supply
|
Overvoltage category |
III
|
Capacitive load |
10000 µF max. Capacitive load starting, Output characteristics
|
Power output |
240 W
|
Safety performance level (EN ISO 13849-1) |
None
|
SIL (IEC 61508) |
None
|
Tripping characteristic |
B
|
Ambient operating temperature - max |
70 °C
|
Ambient operating temperature - min |
-25 °C
|
Ambient storage temperature - max |
85 °C
|
Ambient storage temperature - min |
-40 °C
|
Built-in height |
124 mm
|
Built-in width |
50 mm
|
Equipment heat dissipation, current-dependent Pvid |
28 W
|
Heat dissipation capacity Pdiss |
28 W
|
Heat dissipation per pole, current-dependent Pvid |
9.3 W
|
Input voltage at AC 50 Hz - max |
575 V
|
Input voltage at AC 50 Hz - min |
320 V
|
Input voltage at AC 60 Hz - max |
575 V
|
Input voltage at AC 60 Hz - min |
320 V
|
Input voltage at DC - max |
800 V
|
Input voltage at DC - min |
450 V
|
Nominal output current 1 |
10 A
|
Terminal capacity (flexible with ferrule AWG) |
Input: 18 - 10
Output: 16-10 Signal: 20 - 16 |
Protection class |
1 (with PE connection)
|
Voltage tolerance |
± 2 %, Rated output voltage
|
Relative humidity |
5 - 95% RH (non-condensing)
|
Residual ripple |
< 100 mVpp (PARD at 20 MHz)
|
Inrush current |
< 20 A at 3 x 400 V AC (Inrush current limitation I²t (+25 °C))
< 25 A at 3 x 500 V AC (Inrush current limitation I²t (+25 °C)) |
Supply frequency |
47 Hz, Input, min. Range
50/60 Hz, Input, Rated value 63 Hz, Input, max. Range |
Insulation resistance |
4 kV AC (input/output)
2 kV AC (input) 1.5 kV AC (output) |
Efficiency |
> 89.5 % (3 x 500 V AC)
> 89.5 % (3 x 400 V AC) |
Vibration resistance |
10 - 500 Hz at 30 m/s² (3 G max ) for 60 min. in X-axis, Y-axis, Z-axis directions, (IEC/EN 60068-2-6)
|
Ramp/run-up time |
< 1000 ms
|
Leakage current at ground IPE - max |
< 3.5 mA (at 3 x 500 V AC)
|
LED indicator |
Status indication of "DC OK": Green LED
|
Mean time between failures (MTBF) |
> 700,000 h
|
Nominal output current 2 |
0 A
|
Nominal output current 3 |
0 A
|
Number of phases |
3
|
Output current 1 - max |
10 A
|
Output current 2 - max |
0 A
|
Output current 3 - max |
0 A
|
Output current at AC, 50 Hz - max |
10 A
|
Output current at AC, 60 Hz - max |
10 A
|
Output current at DC - max |
10 A
|
Output voltage 1 - max |
28 V
|
Output voltage 1 - min |
24 V
|
Output voltage 2 - max |
0 V
|
Output voltage 2 - min |
0 V
|
Output voltage 3 - max |
0 V
|
Output voltage 3 - min |
0 V
|
Output voltage at DC - max |
28 V
|
Shock resistance |
50 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 3 Impacts
|
Terminal capacity (flexible with ferrule) |
Input: 0.82 - 5.2 mm²