| Product Name |
Eaton xEffect - XNH circuit protection
|
| Catalog Number |
EP-500618
|
| Product Length/Depth |
204 mm
|
| Product Height |
129 mm
|
| Product Width |
53 mm
|
| Product Weight |
0.662 kg
|
| Compliances |
RoHS Directive
|
| Certifications |
IEC/EN 60947-3
|
| Features |
Halogen free
|
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Is the panel builder's responsibility.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Ui = 800 V AC
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Frequency rating |
50 to 60 Hz
|
| Pollution degree |
2
|
| Utilization category |
AC-22 B
AC-21 B |
| Creepage resistance |
CTI 600
|
| Equipment heat dissipation, current-dependent |
12 W
|
| Rated uninterrupted current (Iu) |
125 A
|
| Total heat dissipation without fuses at Ith |
12 W
|
| Voltage rating at AC |
690
|
| Conditioned rated short-circuit current Iq |
80 kA
|
| Number of poles |
Three-pole
|
| Rated impulse withstand voltage (Uimp) |
6 kV
|
| Connection type |
Flat connection
|
| Degree of protection |
IP30
IP2XC (contact protection, XNH installed) Other |
| Rated short-time withstand current (Icw) |
5 kA
|
| Direction of incoming supply |
As required
|
| Electrical connection type of main circuit |
Frame clamp
|
| Actuator position |
Front side
|
| Actuator type |
Cover grip
|
| Equipment heat dissipation, current-dependent Pvid |
12 W
|
| Heat dissipation at 80% without fuses |
8 W
|
| Heat dissipation per pole, current-dependent Pvid |
4 W
|
| Suitable for |
Busbar mounting
Front mounting |
| Functions |
Basic device
|
| Overvoltage category |
III
|
| Suitable for fuses |
NH000
|
| Cable entry type |
Bottom
|
| Mounting method |
Busbars of 60 mm
|
| Rated operation current (Ie) |
125 A
|
| Flammability characteristics (UL) |
Self-extinguishing (UL 94)
|
| Type |
Basic device
|
| Special features |
Overlap protector for busbar system included
|
| Degree of protection (front side) |
IP30
|
| Lifespan, electrical |
200 operations
|
| Lifespan, mechanical |
1400 operations
|
| Terminal capacity (stranded cable) |
1.5 mm² - 50 mm² at box terminal
|
| Operating altitude without derating - max |
2000 m
|
| Permitted power loss per fuse link - max |
9 W
|
| Rated insulation voltage (Ui) |
800 VAC
|
| Rated operating voltage (Ue) at AC - max |
690 V
|
| Rated operational current for specified heat dissipation (In) |
125 A
|