1500VA 900W Line-Interactive UPS - 8 C13 Outlets, AVR, 230V, 50/60 Hz, USB, DB9, LCD, 2U Rack/Tower
Product Name |
Eaton Tripp Lite series SmartPro UPS
|
Catalog Number |
SMX1500LCD
|
UPC |
037332126078
|
Product Length/Depth |
10.5 in
|
Product Height |
3.5 in
|
Product Width |
17.25 in
|
Product Weight |
29.4 lb
|
Compliances |
RoHS
SASO CE Marked |
Certifications |
IEC/EN 62040-2
IEC/EN 62040-1 GoST-R |
Topology |
Line-interactive
|
Form factor |
Rackmount
|
Rack size |
2U
|
Package contents |
|
Input nominal voltage |
230 VAC
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Receptacle |
C13
|
Output nominal voltage |
220V default(220/230/240V)
|
Electric current - max |
|
Battery replacement |
IMPORTANT BATTERY REPLACEMENT INFORMATION > If your SMX1500LCD UPS has no battery replacement door, please contact a local electronics repair technician to source and install a matching replacement battery; If your SMX1500LCD UPS is equipped with a battery access door, please order Tripp Lite RBC1500 (quantity 1) replacement battery
|
Runtime at half load |
12 min
|
Relative humidity |
0-95% non-condensing
|
Front Panel LCD Display |
Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting; STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS Operating Mode Display; CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling, Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement
|
Output Receptacles |
C13
|
Product Highlights |
8 C13 outlets
Corrects under- and overvoltages from 144V to 282V Interactive LCD monitoring screen 12 min. runtime at half load; 4.5 min. at full load Monitoring of power conditions via PowerAlert software Protects equipment against blackouts, brownouts, overvoltages, surges and line noise Keeps AC power running during blackouts to allow time for file saves and safe shutdown Maintains continuous 230V nominal output during brownouts and overvoltages Easy-to-read LCD allows real-time monitoring of voltage, battery status and other data High 96% efficiency with low BTU ratings saves electricity and lowers your energy costs |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
Nominal Output Voltage |
220V
230V 240V |
Network Management Cards Details |
Network management not supported
|
Phase (input) |
Single-phase
|
Runtime at full load |
4.5 min. (900W)
|
Communication interface |
DB9 Serial
USB (HID enabled) USB cabling included |
Battery Access |
Includes battery access door
|
Dc Voltage |
24
|
Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
Communications Cable |
USB cabling included
|
Included Output Power Cables |
Includes 2 C13 to C14 output power cables.
|
Input Circuit Breakers |
5A
|
High Voltage Transfer to Battery Power |
282
|
Low Voltage Transfer to Battery Power |
144
|
Undervoltage Correction |
Input voltages between 177 and 199 are boosted by 14%
|
Application |
|
Switch configuration |
ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen configuration options
|
Hot Swap PDU Options |
PDUBHV10 (2U / 8 C13 outlets)
|
AC suppression joule rating |
360
|
Housing material |
ABS
|
Output AC waveform (AC mode) |
Sine wave
|
Output AC waveform (battery mode) |
PWM sine wave
|
Output Capacity (kVA) |
1.5
|
Output Capacity (kW) |
0.9
|
Output Capacity (VA) |
1500
|
Primary UPS Depth (mm) |
267
|
Primary UPS Height (mm) |
89
|
Primary UPS Width (mm) |
438
|
AC Suppression Response Time |
Instantaneous
|
Alarm Interface |
Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to indicate low-battery status
|
Audible Alarms |
Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD interface (see manual)
|
Battery Start Capability |
Cold-start operation supported
|
Cooling Method |
Convection
|
Battery Replacement Description |
Hot-swappable, user-replaceable internal battery cartridge
|
LED Indicators |
Front panel LCD display
|
Frequency Rating Details |
Automatic frequency selection
|
Output Voltage Regulation (Line Mode) |
-18%, +8%
|
Output Voltage Regulation(Battery Mode) |
+/- 5%
|
Overvoltage Correction |
Input voltages between 245 and 282 are reduced by 12%
|
Rechargeable Battery |
4.5 hours from 10% to 90%
|
Storage Temperature |
5° to 122°F (-15° to 50°C)
|
Included Mounting Accessory Description |
Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement
|
Input Connection Description |
Chassis mounted C14 inlet accepts user-supplied AC power cord with country specific cordsets
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions
|
Nominal Voltage Details |
230V nominal output in battery mode
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 144 to 282
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
Maximum Input Amps |
4
|
Minimum Required Rack Depth (cm) |
35.56
|
Minimum Required Rack Depth (inches) |
14
|
UPS Dataline Suppression Details |
RJ11 telephone cable included
|
UPS Power Module Dimensions |
3.5 x 17.25 x 10.5
|
Power Mode Transfer Time |
3 milliseconds (AC to battery mode) / 2 milliseconds (battery to AC mode)
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
C14 inlet
|
Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
|
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out)
10/100Base T Ethernet |
High Availability UPS Features |
Hot swappable batteries
Surge/noise protection Automatic voltage regulation (AVR) |