下载文档 () / 20
动力,因我们而不同*

SMX1500XLRT2UN

SmartPro 230V 1500VA 1350W Line-Interactive Sine Wave UPS, 2U, Extended Run, WEBCARDLX, LCD, USB, DB9

常用规格

Product Name
Eaton Tripp Lite series SmartPro UPS
Catalog Number
SMX1500XLRT2UN
UPC
037332256423
Product Length/Depth
23.3 in
Product Height
8.8 in
Product Width
19.9 in
Product Weight
43.1 lb
Compliances
CE Marked
RoHS
Certifications
IEC/EN 62040-2
GoST-R
IEC/EN 62040-1

产品规格

Topology
Line-interactive
Rack size
2U
VA rating
1500 VA
Package contents
  • 1500VA 1500W 208V Line-Interactive UPS
  • WEBCARDLXE network management card
  • USB cable
  • DB9 cable
  • Rack-mounting hardware
  • Tower support stands
  • Safety instructions
  • Advanced User Guide
Nominal frequency
50/60 Hz
Input frequency range
50/60 Hz
Receptacle
C13
Output nominal voltage
208V default (200/208/220/230/240V)
Electric current - max
10A
Runtime graph
Battery replacement
Pre-December 2023: RBC93-2U Post-January 2024: 744-A4801
Battery type
Valve Regulated Lead Acid (VRLA)
Extended battery capability
Extended runtime supported via optional external battery packs
Runtime at half load
14 min
Noise level
45 dBA maximum, front side 1m
Relative humidity
20-95% non-condensing
Front Panel LCD Display
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options)
Input Plug Type
C14
Output Receptacles
C13
Output Receptacles Details
Compatible with Eaton Tripp Lite Power Cords
Product Features
Individually Controllable Load Banks
Expandable Runtime
Emergency Power Off (EPO)/Remote On-Off (ROO)
Product Highlights
Included WEBCARDLXE network interface allows 24/7 remote access and control
Unity power factor ensures maximum power possible at each power rating
2 year warranty, 3 year with registration. (Worldwide) Note: Registration is required for 3 year warranty.
Keeps equipment running during outages to allow time for file saves and safe shutdown
Protects equipment against blackouts, brownouts, transient surges and line noise
2-line front-panel LCD with 10 selectable screens reports detailed UPS and site power info
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Office software at https://tripplite.eaton.com/poweralert
SNMP Compatibility
SNMP V1, V2c, V3
Nominal Output Voltage
200V
208V
220V
230V
240V
Network Management Cards
WEBCARDLXE
Network Management Cards Details
Network management card included
Output power factor
1
Phase (input)
Single-phase
Runtime at full load
5 min. (1500W)
Communication interface
Micro-USB, USB and DB9 cabling included
USB
EPO (emergency power off)
Contact closure
Pre-installed network card
DB9 Serial
Slot for SNMP / Web interface
Battery Access
Front panel battery access door
Typical Battery Runtime
Expandable Runtime
Dc Voltage
48
Operating Temperature Range
32° to 104°F (0° to 40°C)
Communications Cable
Micro-USB, USB and DB9 cabling included
Grounding Details
Rear panel grounding lug
Included Output Power Cables
Set of 2 C13 to C14 power cables included
Optional Mounting Accessory Notes
Optional 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm)
Load Management Receptacles
Two switchable two-outlet C13 load banks
High Voltage Transfer to Battery Power
294 (Normal/Extended Modes)
Low Voltage Transfer to Battery Power
160V (Normal Mode), 150V (Extended Mode)
Undervoltage Correction
Increases incoming voltage between 162-184V (Normal Mode) or 151-184V (Extended Mode) by 15%
Network UPS Tools (NUT) Compatibility
NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stable-hcl.html?manufacturer=Tripp%20Lite
Application
  • Large Network
  • High-End Desktop/Small Network
Switch configuration
5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control functions. LX Platform Interface: Recessed reset switch for interface reboot and factory reset
Hot Swap PDU Options
PDUBHV10 (2U / 8 C13 outlets)
AC suppression joule rating
175
Housing material
Steel
Output AC waveform (AC mode)
Sine wave
Output AC waveform (battery mode)
Pure Sine wave
Output Capacity (kVA)
1.5
Output Capacity (Watts)
1500
Operating Elevation
  • 0-3,000
  • 0-10000 ft. (0-3000 m)
Primary UPS Depth (mm)
447
Primary UPS Height (mm)
86
Primary UPS Width (mm)
437
AC Suppression Response Time
Instantaneous
Alarm Interface
Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing
Audible Alarms
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
Battery Start Capability
Cold-start operation supported
Cooling Method
Fan
Battery Replacement Description
Hot-swappable, user replaceable batteries
LED Indicators
UPS: 3 status-indicating LEDs (normal, battery mode, alarm/fault); LED colors (green = ON, orange = On battery, flashing orange = below warning level, red = alarm/fault). LX Platform Interface Status: Network Link/Activity (Green): Flashes for network activity. Network Speed (Yellow): 10 Mbps (Flashing), 100 Mbps (On steady). Normal Operation (Solid Green); Software Update (Alternating Green/Orange ~1/sec); Factory Reset (Alternating Green/Orange ~2/sec).
Frequency Rating Details
Automatic frequency selection
Minimum Required Rack Depth With External Battery Pack
21
Minimum Required Rack Depth Without External Battery Pack
21
Output Voltage Regulation (Line Mode)
208V (-13%, +15%)
Output Voltage Regulation(Battery Mode)
-10%, +6%
Overvoltage Correction
Reduces incoming voltage between 265-294V (Normal Mode / Extended Mode) by 13%
Rechargeable Battery
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Storage Temperature
5° to 122°F (-15° to 50°C)
Form factor
Rackmount
Wall-mount
Tower
Included Mounting Accessory Description
Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation.
Input Connection Description
IEC320-C14 input connection accepts a variety of detachable cordsets to match country or site-specific wall receptacles
Network Monitoring Port
RJ45 Network port, Micro-USB Configuration/Console port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
Network Monitoring Port Description
Pre-installed WEBCARDLXE supports detailed monitoring and management of UPS and site power conditions. Not compatible with WEBCARDLX.
Nominal Voltage Details
208V nominal output in battery mode
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 150 to 294V
Maximum Input Amps
10
Minimum Required Rack Depth (cm)
53.34
Minimum Required Rack Depth (inches)
21
UPS Power Module Dimensions
3.4 x 17.2 x 17.6
Power Mode Transfer Time
1-4ms for normal mode, >5ms for sensitive mode
Optional Accessories
2 post rackmount (103007018-5591)
2 post rackmount (2POSTRMKITWM)
EMI AC Noise Suppression
EMI / RFI AC Noise Suppression
UPS Input Connection Type
C14 inlet
External Battery Pack Compatibility
BP48VRM2U (limit 4)
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks
Input Nominal Voltage
208 VAC
Network Compatibility
10 Mbps
100 Mbps (Fast Ethernet)
High Availability UPS Features
Hot swappable batteries
Surge/noise protection
Sine wave output
Auto probe monitoring and reboot (included)
Automatic voltage regulation (AVR)
Expandable battery backup
Remote management
Nominal Input Voltage Supported
208 VAC

导出产品规格