| Product Name |
Eaton Tripp Lite series SmartPro UPS
|
| Catalog Number |
SMX3000XLRT2U
|
| UPC |
037332120502
|
| Product Length/Depth |
20.25 in
|
| Product Height |
9 in
|
| Product Width |
23.75 in
|
| Product Weight |
60.2 lb
|
| Compliances |
FCC Class A
RoHS CE Marked |
| Certifications |
IEC/EN 62040-2
|
| Topology |
Line-interactive
|
| Rack size |
2U
|
| VA rating |
3000 VA
|
| Package contents |
|
| Input nominal voltage |
230 VAC
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Receptacle |
|
| Output nominal voltage |
230V
|
| Electric current - max |
15A
|
| Battery replacement |
RBC94-2U
|
| Runtime at half load |
10 min
|
| Noise level |
45 dBA maximum, front side 1m
|
| Relative humidity |
0-95% non-condensing
|
| Input Plug Type |
C20
|
| Output Receptacles |
C19
C13 |
| Output Receptacles Details |
Compatible with Eaton Tripp Lite Power Cords
|
| Product Features |
Individually Controllable Load Banks
Expandable Runtime |
| Product Highlights |
C20 inlet; 8 C13 and 1 C19 outlets; Includes 3 C13 to C14 cables
Detailed status LEDs; 3 switched output load banks 230V nominal output during brownouts to 158V and overvoltages to 278V 3kVA / 3000VA / 2250W line interactive 2U rack/tower UPS; Sine wave output Add optional WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature Extended runtime options up to 1600W |
| PowerAlert Software |
Included
|
| Nominal Output Voltage |
230V
|
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.75
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
3.35 min. (2250W)
|
| Communication interface |
EPO (emergency power off)
Slot for SNMP / Web interface DB9 Serial USB (HID enabled) USB and DB9 serial cables included |
| Battery Access |
Front panel battery access door
|
| Typical Battery Runtime |
Expandable Runtime
|
| Dc Voltage |
48
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and DB9 cabling included
|
| Grounding Details |
Back panel grounding lug
|
| Included Output Power Cables |
Includes 3 C13 to C14 output power cables
|
| Input Circuit Breakers |
20A
|
| Optional Mounting Accessory Notes |
Optional 2-9USTAND enables upright tower UPS placement; 2POSTRMKITWM enables wall-mount and 2-post rackmount installation; 4POSTRAILKITWM enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm); UPSHDEARKIT enables installation in 2 or 4-post racks using front vertical rails only, without rear support
|
| Output Circuit Breakers |
10A (x2) - each breaker protects 4 C13 outlets, C19 outlet does not include a breaker
|
| Load Management Receptacles |
Three switchable two-outlet C13 load banks
|
| High Voltage Transfer to Battery Power |
282
|
| Low Voltage Transfer to Battery Power |
151
|
| Undervoltage Correction |
Input voltages between 182 and 206 are boosted by 12%
|
| Application |
|
| Switch configuration |
2 Switches control off/on power status and alarm-cancel/self-test operation; Rear dip-switch for charger rate adjustment
|
| AC suppression joule rating |
480
|
| Housing material |
Steel
|
| Output AC waveform (AC mode) |
Sine wave
|
| Output AC waveform (battery mode) |
Pure Sine wave
|
| Output Capacity (kVA) |
3
|
| Output Capacity Details |
Output is reduced to 1600W maximum when used with external battery packs
|
| Primary UPS Depth (mm) |
483
|
| Primary UPS Height (mm) |
89
|
| Primary UPS Width (mm) |
445
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate low-battery status
|
| Audible Alarms |
Audible alarm indicates power-failure, overload and low-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status
|
| Frequency Rating Details |
Automatic frequency selection
|
| Minimum Required Rack Depth With External Battery Pack |
26
|
| Minimum Required Rack Depth Without External Battery Pack |
22.5
|
| Output Voltage Regulation (Line Mode) |
230V (-15%, +6% )
|
| Output Voltage Regulation(Battery Mode) |
+/- 5%
|
| Overvoltage Correction |
Input voltages between 244 and 278 are reduced by 12%
|
| Rechargeable Battery |
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
|
| Storage Temperature |
5° to 122°F (-15° to 50°C)
|
| Form factor |
Rackmount
|
| Included Mounting Accessory Description |
Included 4POSTRAILKIT mounting bracket enables installation in 4 post racks from 20.5 to 36 inches (521 to 914mm)
|
| Input Connection Description |
User supplies input cabling with C19 output connection
|
| Network Monitoring Port Description |
Supports detailed monitoring of UPS and site powe.r conditions; 1 USB port and 1 DB9 serial port.
|
| Nominal Voltage Details |
230v nominal inverter output voltage
|
| Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 158 to 278
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
15
|
| Minimum Required Rack Depth (cm) |
55.88
|
| Minimum Required Rack Depth (inches) |
22
|
| UPS Power Module Dimensions |
3.5 x 17.5 x 19
|
| Power Mode Transfer Time |
4 ms (AC to Battery); 2 ms (Battery to AC) typical
|
| Output Capacity (VA) |
3000
|
| Output Capacity (kW) |
2.25
|
| Optional Accessories |
2 post rackmount (2POSTRMKITWM)
2-4 post front rail rackmount (UPSHDEARKIT) 4 post rackmount short-depth (4POSTRAILKITWM) Tower (2-9USTAND) Wallmount (2POSTRMKITWM) |
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
C20 inlet
|
| External Battery Pack Compatibility |
BP48V24-2U (limit 1)
BP48V60RT-3U (multi-pack compatible) BP48V27-2US (multi-pack compatible) |
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Individually controllable load banks |
| High Availability UPS Features |
Auto probe monitoring and reboot (requires WEBCARDLX)
Automatic voltage regulation (AVR) Remote management Surge/noise protection Hot swappable batteries |
| Nominal Input Voltage Supported |
230 VAC
|