| Product Name |
Eaton Tripp Lite series SmartOnline UPS
|
| Catalog Number |
SUINT2200LCD2U
|
| UPC |
037332183330
|
| Product Length/Depth |
23.82 in
|
| Product Height |
3.41 in
|
| Product Width |
17.33 in
|
| Product Weight |
59.75 lb
|
| Warranty |
2 year limited
|
| Compliances |
ENERGY STAR certified
RoHS CE Marked FCC Compliant REACH |
| Certifications |
UL 1778
CSA certified CSA 22.2 cTUVus NOM |
| Topology |
Online/Double-conversion
|
| Rack size |
2U
|
| Color |
Black
|
| VA rating |
2200 VA
|
| Wattage |
2000 W
|
| Package contents |
|
| Surge protection |
Yes
|
| Internal bypass |
Yes
|
| Current Crest Ratio |
3:1
|
| Input connection |
C20
|
| Input cord length |
6 ft
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Input power factor |
.99
|
| Receptacle |
(8) C13; (2) C19
|
| Number of Outputs C13 |
8
|
| Number of Outputs C19 |
2
|
| Output waveform |
True sine wave
|
| Runtime graph |
View runtime graph
|
| Battery replacement |
EBP-1616 *Note: EBP-1616 is the replacement battery for the SUINT2200LCD2U 2023 UPS design update featured on this page. For the replacement battery in the previous design of SUINT2200LCD2U, please see part number RBC48S
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Extended battery capability |
|
| Standard factory warranty |
2-year limited
|
| Extended service plans |
|
| Runtime at half load |
16.6 min
|
| Communication |
|
| Expansion slots |
|
| Includes network card |
No
|
| User interface |
LCD display
|
| Relative humidity |
0-96% non-condensing
|
| Temperature range |
0° to 40°C (32° to 104°F)
|
| Front Panel LCD Display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, frequency, operating mode, alarm function and a variety of additional options
|
| Runtime graph |
|
| Input Plug Type |
C20
|
| Output Receptacles |
C13
C19 |
| Output Receptacles Details |
Compatible with Eaton Tripp Lite Power Cords
|
| Product Features |
Individually Controllable Load Banks
Expandable Runtime L6-20P Emergency Power Off (EPO)/Remote On-Off (ROO) |
| Product Highlights |
2-year limited warranty (Worldwide)
Updated design for 2023 Optional WEBCARDLXE network card enables full remote access and control Zero transfer time between on-line and battery modes for uninterrupted operation Menu-driven LCD keeps you up to date with status info and other vital analytics Keeps equipment running during outages to allow time for file saves and safe shutdown Protects equipment against blackouts, brownouts, transient surges and line noise |
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
200V
208V 220V 230V 240V |
| Network Management Cards |
WEBCARDLXE
|
| Network Management Cards Details |
Network management card optional
|
| Output power factor |
0.9
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
6 min. (2000W)
|
| Communication interface |
RS-232
USB Contact closure Slot for SNMP / Web interface |
| Battery Access |
Battery access door
|
| Typical Battery Runtime |
Expandable Runtime
|
| Dc Voltage |
72
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB and RS232 cable included
|
| Included Output Power Cables |
(2) IEC 10A 6ft. output cables
|
| Optional Mounting Accessory Notes |
2 post rail kit available, part # RK2PC
|
| Load Management Receptacles |
Two switchable load banks. Group 1: Two C13 outlets plus one C19 outlet; Group 2: Two C13 outlets.
|
| Application |
Mission Critical Applications
|
| Switch configuration |
RPO / ROO
|
| AC suppression joule rating |
296
|
| Housing material |
Metal
|
| Output AC waveform (AC mode) |
Pure Sine wave
|
| Output AC waveform (battery mode) |
Pure sine wave
|
| Output Capacity (kVA) |
2.2
|
| Output Capacity Details |
220/230/240V: 2200VA / 2200W;
208V(default)/200V: 2200VA / 2000W
|
| Operating Elevation |
Up to 3000m
|
| AC Suppression Response Time |
Instantaneous
|
| Alarm Interface |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available
|
| Audible Alarms |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Cooling Method |
Fan
|
| Battery Replacement Description |
Hot-swappable, user replaceable batteries
|
| LED Indicators |
4 status-indicating LEDs
|
| Frequency Rating Details |
Online Mode: Sync with line ±5% of nominal line frequency (outside this range: ±0.5% of auto-selected nominal frequency). Battery Mode: ±0.5% of auto-selected nominal frequency
|
| Output Voltage Regulation (Economy Line Mode) |
+/- 1%
|
| Output Voltage Regulation (Line Mode) |
+/- 1%
|
| Output Voltage Regulation(Battery Mode) |
+/- 2%
|
| Rechargeable Battery |
3 hours recharge to 90%
|
| Recommended Electrical Service |
208V
|
| Storage Temperature |
With battery: 32° to 104°F (0° to 40°C); without battery: -13° to 131°F (-25° to 55°C)
|
| Form factor |
Rackmount
|
| Included Mounting Accessory Description |
Includes 4 post rackmount and tower pedestal accessories
|
| Input Current |
10.57A
|
| Input Nominal Voltage Description |
208V factory default
|
| Network Monitoring Port Description |
WEBCARDLXE Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; not compatible with WEBCARDLX
|
| Nominal Voltage Details |
208V default
|
| Voltage Regulation Description |
Online, double-conversion power conditioning
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Plug Type |
NEMA L6-20P
|
| Maximum Input Amps |
11
|
| Minimum Required Rack Depth (cm) |
68.07
|
| Minimum Required Rack Depth (inches) |
26.8
|
| UPS Input Cord Length (m) |
1.8
|
| Power Mode Transfer Time |
0 ms.
|
| Output Capacity (VA) |
2200
|
| Optional Accessories |
2 post rackmount (RK2PC)
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
C20 inlet
|
| External Battery Pack Compatibility |
BP72RT
|
| Green Energy-Saving Features |
High efficiency economy mode operation
Individually controllable load banks |
| Input Nominal Voltage |
200 VAC
208 VAC 220 VAC 230 VAC 240 VAC |
| High Availability UPS Features |
Hot swappable batteries
Surge/noise protection Expandable battery backup Pure sine wave output Remote management Zero transfer time On-Line/Double-Conversion |