Eaton Moeller® series SDAINL Star-delta contactor combination, 380 V 400 V: 37 kW, 400 V 50 Hz, AC operation
| Product Name | 
                                                Eaton Moeller series star-delta contactor combination
                                             | 
| Catalog Number | 
                                                101386
                                             | 
| Product Length/Depth | 
                                                147 mm
                                             | 
| Product Height | 
                                                115 mm
                                             | 
| Product Width | 
                                                188 mm
                                             | 
| Product Weight | 
                                                2.94 kg
                                             | 
| Certifications | 
                                                CE
                                             | 
| Used with | 
                                                ETR4-51
                                             | 
| Electrical connection type for auxiliary- and control-current circuit | 
                                                Screw connection
                                             | 
| Number of poles | 
                                                Three-pole
                                             | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Frequency rating | 
                                                50 Hz
                                             | 
| Pollution degree | 
                                                3
                                             | 
| Utilization category | 
                                                AC-3: Normal AC induction motors: starting, switch off during running
                                             | 
| Connection | 
                                                Screw terminals
                                             | 
| Ambient operating temperature - max | 
                                                60 °C
                                             | 
| Ambient operating temperature - min | 
                                                -25 °C
                                             | 
| Ambient operating temperature (enclosed) - max | 
                                                40 °C
                                             | 
| Ambient operating temperature (enclosed) - min | 
                                                -25 °C
                                             | 
| Ambient storage temperature - max | 
                                                80 °C
                                             | 
| Ambient storage temperature - min | 
                                                -40 °C
                                             | 
| Equipment heat dissipation, current-dependent Pvid | 
                                                20 W
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Heat dissipation per pole, current-dependent Pvid | 
                                                6.7 W
                                             | 
| Application | 
                                                Star-delta motor starting for contactor combinations
                                             | 
| Product category | 
                                                Contactor combinations
                                             | 
| Electrical connection type of main circuit | 
                                                Screw connection
                                             | 
| Voltage type | 
                                                AC
                                             | 
| Degree of protection | 
                                                IP00  NEMA Other | 
| Number of auxiliary contacts (normally closed contacts) | 
                                                1
                                             | 
| Number of auxiliary contacts (normally open contacts) | 
                                                1
                                             | 
| Number of contacts (normally closed) as main contact | 
                                                0
                                             | 
| Number of main contacts (normally open contact) | 
                                                9
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                                400 V
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                                400 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                                0 V
                                             | 
| Overvoltage category | 
                                                III
                                             | 
| Duty factor | 
                                                100 %
                                             | 
| Changeover time | 
                                                20 s, max.
                                             | 
| Interference immunity | 
                                                According to EN 60947-1
                                             | 
| Functions | 
                                                Star-delta contactor
                                             | 
| Rated control supply voltage (Us) at DC - max | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at DC - min | 
                                                0 V
                                             | 
| Rated insulation voltage (Ui) | 
                                                690 V
                                             | 
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 
                                                70 A
                                             | 
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 
                                                70 A
                                             | 
| Rated operational current for specified heat dissipation (In) | 
                                                70 A
                                             | 
| Rated operational power at AC-3, 380/400 V, 50 Hz | 
                                                37 kW
                                             | 
| Rated operational power (NEMA) | 
                                                0 kW
                                             | 
| Static heat dissipation, non-current-dependent Pvs | 
                                                8.7 W
                                             | 
| Suitable for | 
                                                Also motors with efficiency class IE3
                                             | 
| Rated operational power at AC-3, 500 V, 50 Hz | 
                                                45 kW
                                             | 
| Rated operational power at AC-3, 690 V, 50 Hz | 
                                                37 kW
                                             | 
| Actuating voltage | 
                                                400 V 50 Hz
                                             | 
| Number of auxiliary contacts (change-over contacts) | 
                                                0
                                             | 
| Voltage type of operating voltage | 
                                                AC
                                             | 
| Operating voltage at AC, 50 Hz - min | 
                                                230 V
                                             | 
| Operating voltage at AC, 50 Hz - max | 
                                                690 V
                                             | 
| Operating voltage at AC, 60 Hz - min | 
                                                230 V
                                             | 
| Operating voltage at AC, 60 Hz - max | 
                                                690 V
                                             | 
| Operating voltage at DC - min | 
                                                0 V
                                             | 
| Operating voltage at DC - max | 
                                                0 V
                                             |