Eaton Moeller series Power Defense - Molded Case Circuit Breaker. Switch-disconnector, 4 p, 125A, frame size 1
| Product Name |
Eaton Moeller series Power Defense molded case switch-disconnector
|
| Catalog Number |
112000
|
| Product Length/Depth |
88 mm
|
| Product Height |
145 mm
|
| Product Width |
120 mm
|
| Product Weight |
1.15 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC
|
| Amperage Rating |
125 A
|
| Voltage rating |
690 V - 690 V
|
| Circuit breaker frame type |
LN1
|
| Features |
Version as maintenance-/service switch
Motor drive optional Version as emergency stop installation Version as main switch |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Pollution degree |
3
|
| Mounting Method |
Ground mounting
Intermediate mounting Built-in device fixed built-in technique Fixed Distribution board installation |
| Equipment heat dissipation, current-dependent |
17.81 W
|
| Rated short-time withstand current (Icw) |
2 kA
|
| Electrical connection type of main circuit |
Frame clamp
|
| Number of auxiliary contacts (change-over contacts) |
0
|
| Number of auxiliary contacts (normally closed contacts) |
0
|
| Number of auxiliary contacts (normally open contacts) |
0
|
| Rated insulation voltage (Ui) |
690 V
|
| Rated operating frequency |
50 Hz
|
| Rated operating power at AC-23, 400 V |
55 kW
|
| Rated operating power at AC-3, 400 V |
0 kW
|
| Switch positions |
I, +, 0
|
| Lifespan, mechanical |
20000 operations
|
| Overvoltage category |
III
|
| Rated operational current |
160 A (690 V AC-1, making and breaking capacity)
160 A (415 V AC-1, making and breaking capacity) 160 A (415 V AC-22/23A, making and breaking capacity) 160 A (690 V AC-22/23A, making and breaking capacity) |
| Degree of protection (IP), front side |
IP20
|
| Number of poles |
Four-pole
|
| Terminal capacity (copper strip) |
Max. 9 segments of 9 mm x 0.8 mm at box terminal
Min. 2 segments of 9 mm x 0.8 mm at box terminal |
| Handle color |
Gray
|
| Lifespan, electrical |
7500 operations at 690 V AC-1
10000 operations at 415 V AC-1 7500 operations at 415 V AC-3 10000 operations at 400 V AC-1 5000 operations at 690 V AC-3 7500 operations at 400 V AC-3 |
| Functions |
Voltage release optional
Interlockable Disconnectors/main switches |
| Type |
Switch-disconnector
|
| Special features |
Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113.
Isolating characteristics to IEC/EN 60947-3 and VDE 0660.
Busbar tag shroud to VDE 0160 Part 100.
Rated current = rated uninterrupted current: 125 A
|
| Application |
Use in unearthed supply systems at 690 V
|
| Rated conditional short-circuit current (Iq) |
100 kA
|
| Rated conditional short-circuit current with back-up fuse |
PN1(N1)-63…125: 125 AgGgL; PN1(N1)-160: 160 AgGgL
80 kA at 690 V 100 kA at 400/415 V |
| Rated conditional short-circuit current with downstream fuse |
10 kA at 690 V
PN1(N1)-63…125: 125 AgGgL; PN1(N1)-160: 160 AgGgL 100 kA at 400/415 V |
| Short-circuit total breaktime |
< 10 ms
|
| Rated operating voltage (Ue) at AC - max |
400 V
|
| Rated operational current for specified heat dissipation (In) |
125 A
|
| Rated permanent current at AC-21, 400 V |
0 A
|
| Rated short-time withstand current (t = 0.3 s) |
2 kA
|
| Rated short-time withstand current (t = 1 s) |
2 kA
|
| Switching power at 400 V |
0 kW
|
| Handle type |
Rocker lever
|
| Number of operations per hour - max |
120
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
2.8 kA
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
6000 V
|
| Standard terminals |
Box terminal
|
| Terminal capacity (control cable) |
0.75 mm² - 1.5 mm² (2x)
0.75 mm² - 2.5 mm² (1x) |
| Short-circuit protective device fuses - max |
125 A gL
|
| Terminal capacity (copper busbar) |
M6 at rear-side screw connection
Max. 16 mm x 5 mm direct at switch rear-side connection Min. 12 mm x 5 mm direct at switch rear-side connection |
| Terminal capacity (copper solid conductor/cable) |
6 mm² - 16 mm² (2x) direct at switch rear-side connection
6 mm² - 16 mm² (2x) at box terminal 10 mm² - 16 mm² (1x) direct at switch rear-side connection 10 mm² - 16 mm² (1x) at box terminal 16 mm² (1x) at tunnel terminal |
| Terminal capacity (aluminum solid conductor/cable) |
16 mm² (1x) at tunnel terminal
|
| Terminal capacity (copper stranded conductor/cable) |
25 mm² - 70 mm² (1x) at box terminal
25 mm² - 70 mm² (1x) direct at switch rear-side connection 25 mm² (2x) at box terminal 25 mm² - 95 mm² (1x) at tunnel terminal 25 mm² (2x) direct at switch rear-side connection |
| Terminal capacity (aluminum stranded conductor/cable) |
25 mm² - 95 mm² (1x) at tunnel terminal
|