Eaton Moeller series Power Defense - Molded Case Circuit Breaker. Switch-disconnector, 4 p, 160A, frame size 2
| Product Name |
Eaton Moeller series Power Defense molded case switch-disconnector
|
| Catalog Number |
112005
|
| Product Length/Depth |
142 mm
|
| Product Height |
185 mm
|
| Product Width |
140 mm
|
| Product Weight |
2.37 kg
|
| Compliances |
RoHS conform
|
| Certifications |
IEC
|
| Amperage Rating |
160 A
|
| Voltage rating |
690 V - 690 V
|
| Circuit breaker frame type |
LN2
|
| Features |
Motor drive optional
Version as main switch Version as maintenance-/service switch Version as emergency stop installation |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Pollution degree |
3
|
| Mounting Method |
Built-in device fixed built-in technique
Distribution board installation Ground mounting Intermediate mounting Fixed |
| Equipment heat dissipation, current-dependent |
19.66 W
|
| Rated short-time withstand current (Icw) |
3.5 kA
|
| Electrical connection type of main circuit |
Screw connection
|
| Number of auxiliary contacts (change-over contacts) |
0
|
| Number of auxiliary contacts (normally closed contacts) |
0
|
| Number of auxiliary contacts (normally open contacts) |
0
|
| Rated insulation voltage (Ui) |
690 V
|
| Rated operating frequency |
50 Hz
|
| Rated operating power at AC-23, 400 V |
90 kW
|
| Rated operating power at AC-3, 400 V |
0 kW
|
| Switch positions |
I, +, 0
|
| Lifespan, mechanical |
20000 operations
|
| Overvoltage category |
III
|
| Rated operational current |
250 A (690 V AC-1, making and breaking capacity)
250 A (690 V AC-22/23A, making and breaking capacity) 250 A (415 V AC-22/23A, making and breaking capacity) 250 A (415 V AC-1, making and breaking capacity) |
| Degree of protection (IP), front side |
IP20
|
| Number of poles |
Four-pole
|
| Terminal capacity (copper strip) |
Max. 10 segments of 16 mm x 0.8 mm at box terminal
Max. 10 segments of 16 mm x 0.8 mm at rear-side connection (punched) Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched) Min. 2 segments of 9 mm x 0.8 mm at box terminal |
| Handle color |
Gray
|
| Lifespan, electrical |
4000 operations at 690 V AC-3
7500 operations at 400 V AC-1 5000 operations at 690 V AC-1 7500 operations at 415 V AC-1 6000 operations at 400 V AC-3 6000 operations at 415 V AC-3 |
| Functions |
Disconnectors/main switches
Interlockable Voltage release optional |
| Type |
Switch-disconnector
|
| Special features |
|
| Application |
Use in unearthed supply systems at 690 V
|
| Rated conditional short-circuit current (Iq) |
100 kA
|
| Rated conditional short-circuit current with back-up fuse |
80 kA at 690 V
100 kA at 400/415 V PN2(N2)-160…250: 250 AgGgL |
| Rated conditional short-circuit current with downstream fuse |
PN2(N2)-160…250: 250 AgGgL
100 kA at 400/415 V 80 kA at 690 V |
| Short-circuit total breaktime |
< 10 ms
|
| Rated operating voltage (Ue) at AC - max |
400 V
|
| Rated operational current for specified heat dissipation (In) |
160 A
|
| Rated permanent current at AC-21, 400 V |
0 A
|
| Rated short-time withstand current (t = 0.3 s) |
3.5 kA
|
| Rated short-time withstand current (t = 1 s) |
3.5 kA
|
| Switching power at 400 V |
0 kW
|
| Handle type |
Rocker lever
|
| Number of operations per hour - max |
120
|
| Rated short-circuit making capacity Icm at 690 V, 50/60 Hz |
5.5 kA
|
| Rated impulse withstand voltage (Uimp) at auxiliary contacts |
6000 V
|
| Rated impulse withstand voltage (Uimp) at main contacts |
8000 V
|
| Standard terminals |
Screw terminal
|
| Terminal capacity (control cable) |
0.75 mm² - 1.5 mm² (2x)
0.75 mm² - 2.5 mm² (1x) |
| Short-circuit protective device fuses - max |
250 A gL
|
| Terminal capacity (copper busbar) |
M8 at rear-side screw connection
Min. 16 mm x 5 mm direct at switch rear-side connection Max. 20 mm x 5 mm direct at switch rear-side connection |
| Terminal capacity (copper solid conductor/cable) |
4 mm² - 16 mm² (2x) direct at switch rear-side connection
4 mm² - 16 mm² (1x) at box terminal 4 mm² - 16 mm² (1x) direct at switch rear-side connection 16 mm² - 185 mm² (1x) at tunnel terminal 4 mm² - 16 mm² (2x) at box terminal |
| Terminal capacity (aluminum solid conductor/cable) |
16 mm² (1x) at tunnel terminal
|
| Terminal capacity (copper stranded conductor/cable) |
25 mm² - 185 mm² (1x) at box terminal
25 mm² - 185 mm² (1x) at tunnel terminal 25 mm² - 185 mm² (1x) direct at switch rear-side connection 25 mm² - 70 mm² (2x) direct at switch rear-side connection 25 mm² - 70 mm² (2x) at box terminal |
| Terminal capacity (aluminum stranded conductor/cable) |
25 mm² - 185 mm² (1x) at tunnel terminal
|