Product Name |
Eaton ESR5 Contact expansion module
|
Catalog Number |
118706
|
Product Length/Depth |
114.5 mm
|
Product Height |
99 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.173 kg
|
Certifications |
UL File No.: E29184
Certified by UL for use in Canada CSA Class No.: 3211-83; 3211-03 UL 2014/30/EU IEC 62061 UL 508 IEC/EN 60204 EN 50178 CE UL report applies to both US and Canada UL Category Control No.: NKCR; NKCR7 EN ISO 13849-1 CSA-C22.2 No. 14-95 IEC 61508, Parts 1-7 Machines 2006/42/EG |
Catalog Notes |
The base unit determines the maximum stop category according to IEC 61508 and IEC 60204
|
Type |
Contact expansions
|
Mounting method |
Rail mounting possible
Top-hat rail fixing (according to IEC/EN 60715, 35 mm) |
Operating temperature - max |
55 °C
|
Operating temperature - min |
-20 °C
|
Features |
Feedback current path
Safe insulation 6 kV between input circuit / NC contacts, and enable current paths Basic insulation Reinforced insulation |
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Electric connection type |
Screw connection
|
Fitted with: |
Approval for TÜV
Detachable clamps Approval according to UL Feedback circuit |
Pollution degree |
2
|
Climatic proofing |
Damp heat, constant, to IEC 60068-2-3
Dry heat to IEC 60068-2-2 |
Rated impulse withstand voltage (Uimp) |
4000 V AC
|
Air pressure |
795 - 1080 hPa (operation)
|
Altitude |
Max. 2000 m
|
Category (EN 954-1) |
3
|
Degree of protection |
IP20
Installation location: ≥ IP54 Enclosure: IP20 Terminals: IP20 |
Environmental conditions |
Condensation: Non-condensing
Clearance in air and creepage distances according to EN 50178, UL 508, CSA C22.2, No. 14-95 |
Number of inputs |
1-channel
|
Functions |
1-channel
Time function |
Safety performance level (EN ISO 13849-1) |
Level d
|
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-20 °C
|
Ambient storage temperature - max |
70 °C
|
Ambient storage temperature - min |
-40 °C
|
Equipment heat dissipation, current-dependent Pvid |
0 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Nominal current |
84 A
|
Number of outputs (safety related, delayed) with contact |
4
|
Number of outputs (safety related, delayed, semiconductors) |
0
|
Number of outputs (safety related, undelayed) with contact |
0
|
Number of outputs (safety related, undelayed, semiconductors) |
0
|
Number of outputs (signaling function, delayed) with contact |
1
|
Number of outputs (signaling function, delayed, semiconductors) |
0
|
Number of outputs (signaling function, undelayed) with contact |
0
|
Number of outputs (signaling function, undelayed, semiconductors) |
0
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
26.4 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
26.4 V
|
Screwdriver size |
0.6 x 3.5 mm, Terminal screws
2, Terminal screw, Pozidriv screwdriver |
Voltage type |
DC
|
Connection type |
M3 screw terminals
|
Mounting position |
As required
|
Breaking power |
1500 VA max., Output data, resistive load (τ = 0 ms), at 250 V AC (for N/C contacts 65 - 66)
288 W max., Output data, resistive load (τ = 0 ms), at 48 V DC (for N/C contacts 65 - 66) 40 W max., Output data, inductive load (τ = 40 ms), at 48 V DC 35 W max., Output data, inductive load (τ = 40 ms), at 110 V DC 144 W max. resistive load (τ = 0 ms), at 24 V DC (for N/C contacts 65 - 66) 33 W max., Output data, inductive load (τ = 40 ms), at 220 V DC 77 W max., Output data, resistive load (τ = 0 ms), at 110 V DC 88 W max., Output data, resistive load (τ = 0 ms), at 220 V DC 48 W max., Output data, inductive load (τ = 40 ms), at 24 V DC |
Overvoltage category |
III
|
Short-circuit protection rating |
10A gL/gG, NEOZED (N/O), Output fuse, External, Output data
4A gL/gG, NEOZED (N/C), Output fuse, External, Output data |
Duty factor |
100 %
|
Off-delay |
0.3 - 3 s (± 50 %)
|
Emitted interference |
According to EN 61000-6-4
|
Current consumption |
94 mA, DC
94 mA, AC |
Material |
Contacts: silver tin oxide, gold plated (AgSnO2, 0.2 µm Au)
Enclosure: Polyamide (PA), not reinforced |
Interference immunity |
According to EN 61000-6-2
|
Tightening torque |
0.6 Nm, Screw terminals
|
Mounting width |
22.5 mm
|
Suitable for |
Safety relay contact expansion block per DIN EN60204-1/VDE 0113 Part 1 for contact multiplication
Monitoring of position switches Monitoring of emergency-stop circuits The expansion unit can be used for contact multiplication for emergency stop relays and two-hand controls |
Relative humidity |
< 75 %
|
LED indicator |
Status indication of SmartWire-DT network: Green LED
|
Feedback current path |
Delayed feedback current path
|
Pick-up time |
20 ms typ. (K1, K2 - for UN automatic mode)
20 ms typ. (at Uₑ in automatic mode) 20 ms typ. (K1, K2 - for UN manual operation) 20 ms typ. (at Uₑ in manual mode) |
Lifespan, mechanical |
10,000,000 Operations
|
Input |
∞ ms, Simultaneity for inputs 1/2
|
Recovery time |
1000 ms
|
Inrush current |
0.025 - 6 A (N/O)
0.025 - 3 A (N/C) |
Model |
Expansion device
|
Safety type (IEC 61496-1) |
None
|
Vibration resistance |
10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)
|
Safety parameter (EN ISO 13849-1) |
300,000 switching cycles, B10d
PL d, Performance level Cat. 3, Category |
Terminal capacity |
1 x (0.2 – 2.5) mm², solid
1 x (0.25 – 2.5) mm², flexible with ferrule 2 x (0.25 – 1) mm², flexible with ferrule 24 - 12 AWG, solid or stranded 2 x (0.2 – 1) mm², solid |
Rated control supply voltage (Us) at AC, 60 Hz - min |
20.4 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Rated control supply voltage (Us) at DC - min |
0 V
|
Rated insulation voltage (Ui) |
250 V
|
Rated operational current for specified heat dissipation (In) |
0 A
|
Release-delay - max |
0 s
|
Release-delay - min |
0 s
|
Static heat dissipation, non-current-dependent Pvs |
4.52 W
|
Stripping length (main cable) |
7 mm
|
Switching voltage |
250 V
|
Product category |
Electronic safety relays
|
Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
SIL (IEC 61508) |
3
|
Power loss |
Normally 4.52 W
|
Power supply circuit |
2 W (DC operated)
|
Prooftest |
67 Months (Low Demand)
240 Months (High Demand) |
Quadratic summation current |
50 A² (ITH² = I1² + I2² + I3² + I4²)
|
Rated operational voltage |
24 V DC (power supply)
230 V AC |
Safety parameter (IEC 62061) |
SIL 3, Safety integrity level, In accordance with IEC 61508
SILCL 3, Safety integrity level claim limit SILCL 2, Safety integrity level claim limit SIL 2, Safety integrity level, In accordance with IEC 61508 13.5 x 10-10, PFHd, Probability of failure per hour Cat. 3, Category |
Uninterrupted current |
3 A N/C, Limiting continuous current
6 A N/O, Limiting continuous current |
Short-circuit protection |
Fuse 4 A gL/gG (Signal current paths), For output circuits, External
Fuse 10 A gL/gG (Enable current paths), For output circuits, External |
Stop category (IEC 60204) |
1
|
Switching capacity |
3 A at 3600 O/h, AC-15 at 230 V, Outputs
In accordance with IEC 60947-5-1, Outputs 0.4 W 3 A at 3600 O/h, DC-13 at 24 V, Outputs |
Switching frequency |
Max. 0.5 Hz, Input data
|
Power consumption |
4.52 W
|
Control voltage 1 - min |
24 V
|
Control voltage 1 - max |
24 V
|
Control voltage 2 - min |
24 V
|
Control voltage 2 - max |
24 V
|
Control voltage 1 type |
DC
|
Control voltage 2 type |
DC
|
Voltage type of supply voltage |
DC
|
Voltage type of operating voltage |
DC
|
Rated switch current |
6 A
|
Supply voltage at AC, 50 Hz - min |
0 V
|
Supply voltage at AC, 50 Hz - max |
0 V
|
Supply voltage at AC, 60 Hz - min |
0 V
|
Supply voltage at AC, 60 Hz - max |
0 V
|
Supply voltage at DC - min |
24 V
|
Supply voltage at DC - max |
24 V
|
Operating voltage at AC, 50 Hz - min |
0 V
|
Operating voltage at AC, 50 Hz - max |
0 V
|
Operating voltage at AC, 60 Hz - min |
0 V
|
Operating voltage at AC, 60 Hz - max |
0 V
|
Operating voltage at DC - min |
24 V
|
Operating voltage at DC - max |
24 V
|