Eaton ESR5 Safety relays for controlled stop/protective door/light curtain monitoring, 24 V DC/AC, 3 enabling paths
| Product Name |
Eaton ESR5 Safety relay
|
| Catalog Number |
180413
|
| Product Length/Depth |
114.5 mm
|
| Product Height |
99 mm
|
| Product Width |
22.5 mm
|
| Product Weight |
0.165 kg
|
| Certifications |
UL Category Control No.: NKCR; NKCR7
UL report applies to both US and Canada UL File No.: E29184 CSA-C22.2 No. 14-95 EN ISO 13849-1 IEC/EN 61000-6-4 CE IEC 62061 2014/30/EU IEC/EN 60204 IEC/EN 61000-6-2 UL Certified by UL for use in Canada CSA Class No.: 3211-83; 3211-03 UL 508 Machines 2006/42/EG |
| Catalog Notes |
Replacement: ESR5-BWS-31-24VDC (EP-401064)
|
| Type |
|
| Mounting method |
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible |
| Operating temperature - max |
55 °C
|
| Operating temperature - min |
-20 °C
|
| Features |
External contactor monitoring
Safe insulation 6 kV between input circuit and enable current paths Basic insulation Automatic/manually controlled start Feedback current path 3 Non-delayed enable current paths Reinforced insulation |
| 10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
| 10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
| 10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
| 10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
| 10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
| 10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
| 10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
| 10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.2.7 Inscriptions |
Meets the product standard's requirements.
|
| 10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
| 10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
| 10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
| 10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
| 10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
| 10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
| 10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
| Electric connection type |
Screw connection
|
| Fitted with: |
Feedback circuit
Detachable clamps Approval for TÜV Approval according to UL |
| Pollution degree |
2
|
| Rated impulse withstand voltage (Uimp) |
4000 V AC
|
| Air pressure |
795 - 1080 hPa (operation)
|
| Altitude |
Max. 2000 m
|
| Category (EN 954-1) |
4
|
| Degree of protection |
Terminals: IP20
Installation location: ≥ IP54 Enclosure: IP20 IP20 |
| Environmental conditions |
Condensation: Non-condensing
Clearance in air and creepage distances according to EN 50178 |
| Number of inputs |
One- and two-channel
|
| Functions |
2-channel
1-channel |
| Safety performance level (EN ISO 13849-1) |
Level e
|
| Ambient operating temperature - max |
55 °C
|
| Ambient operating temperature - min |
-20 °C
|
| Ambient storage temperature - max |
70 °C
|
| Ambient storage temperature - min |
-40 °C
|
| Equipment heat dissipation, current-dependent Pvid |
0 W
|
| Heat dissipation capacity Pdiss |
0 W
|
| Heat dissipation per pole, current-dependent Pvid |
0 W
|
| Number of outputs (safety related, delayed) with contact |
0
|
| Number of outputs (safety related, delayed, semiconductors) |
0
|
| Number of outputs (safety related, undelayed) with contact |
0
|
| Number of outputs (safety related, undelayed, semiconductors) |
0
|
| Number of outputs (signaling function, delayed) with contact |
0
|
| Number of outputs (signaling function, delayed, semiconductors) |
0
|
| Number of outputs (signaling function, undelayed) with contact |
1
|
| Number of outputs (signaling function, undelayed, semiconductors) |
0
|
| Rated control supply voltage (Us) at AC, 50 Hz - max |
26.4 V
|
| Rated control supply voltage (Us) at AC, 50 Hz - min |
20.4 V
|
| Rated control supply voltage (Us) at AC, 60 Hz - max |
24 V
|
| Screwdriver size |
2, Terminal screw, Pozidriv screwdriver
0.6 x 3.5 mm, Terminal screws |
| Voltage type |
AC/DC
|
| Connection type |
M3 screw terminals
|
| Mounting position |
As required
|
| Breaking power |
288 W max., resistive load (τ = 0 ms), at 48 V DC
33 W max., inductive load (τ = 40 ms), at 220 V DC 144 W max., resistive load (τ = 0 ms), at 24 V DC 77 W max., resistive load (τ = 0 ms), at 110 V DC 1500 VA, max., resistive load (τ = 0 ms), at 250 V AC 48 W max., inductive load (τ = 40 ms), at 24 V DC 40 W max., inductive load (τ = 40 ms), at 48 V DC 35 W max., inductive load (τ = 40 ms), at 110 V DC 88 W max., resistive load (τ = 0 ms), at 220 V DC |
| Overvoltage category |
III
|
| Short-circuit protection rating |
10A gL/gG, NEOZED (N/O), Output fuse, External, Output data
|
| Emitted interference |
According to EN 61000-6-4
|
| Current consumption |
150 mA, AC
70 mA, DC |
| Interference immunity |
According to EN 61000-6-2
|
| Tightening torque |
0.6 Nm, Screw terminals
|
| Mounting width |
22.5 mm
|
| Suitable for |
Module used to safely interrupt electrical circuits
Monitoring of position switches Safety relay for monitoring emergency stop and protective door switch and light curtains Monitoring of emergency-stop circuits |
| Relative humidity |
< 75 %
|
| LED indicator |
Status indication of SmartWire-DT network: Green LED
|
| Pick-up time |
25 ms typ. (K1, K2 - for UN manual operation)
100 ms typ. (K1, K2 - for UN automatic mode) 100 ms typ. (at Uₑ in automatic mode) 25 ms typ. (at Uₑ in manual mode) |
| Input |
∞ ms, Simultaneity for inputs 1/2
|
| Recovery time |
1000 ms
|
| Inrush current |
0.4 A
|
| Model |
Basic device
|
| Safety type (IEC 61496-1) |
None
|
| Vibration resistance |
10 - 150 Hz, Amplitude: 0.15 mm, Acceleration: 2 g, (IEC/EN 60068-2-6)
|
| Safety parameter (EN ISO 13849-1) |
Cat. 4, Category
300,000 switching cycles, B10d PL e, Performance level |
| Terminal capacity |
2 x (0.25 – 1) mm², flexible with ferrule
2 x (0.2 – 1) mm², solid 1 x (0.2 – 2.5) mm², solid 24 - 12 AWG, solid or stranded 1 x (0.25 – 2.5) mm², flexible with ferrule |
| Rated control supply voltage (Us) at AC, 60 Hz - min |
20.4 V
|
| Rated control supply voltage (Us) at DC - max |
24 V
|
| Rated control supply voltage (Us) at DC - min |
24 V
|
| Rated operational current for specified heat dissipation (In) |
0 A
|
| Release-delay - max |
0 s
|
| Release-delay - min |
0 s
|
| Static heat dissipation, non-current-dependent Pvs |
5.16 W
|
| Stripping length (main cable) |
7 mm
|
| Switching voltage |
250 V
|
| Product category |
Electronic safety relays
|
| Protection |
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
|
| SIL (IEC 61508) |
3
|
| Power loss |
Normally 5.16 W
|
| Prooftest |
75 Months (Low Demand)
240 Months (High Demand) |
| Quadratic summation current |
72 A² (ITH² = I1² + I2² + I3²)
|
| Rated operational voltage |
Approx. 24 V DC at input, starting and feedback circuit
24 V AC/DC (power supply) |
| Reset time |
Normally 10 ms
|
| Safety parameter (IEC 62061) |
Cat. 4, Category
SILCL 3, Safety integrity level claim limit SIL 3, Safety integrity level EN 574 Type III C SIL 3, Safety integrity level, In accordance with IEC 61508 5.56 x 10-10, PFHd, Probability of failure per hour |
| Uninterrupted current |
6 A N/C, Limiting continuous current
6 A N/O, Limiting continuous current |
| Short-circuit protection |
Fuse 10 A gL/gG NEOZED, For output circuits, External
|
| Stop category (IEC 60204) |
0
|
| Switching capacity |
5 A at 360 O/h, AC-15 at 230 V, Outputs
3 A at 3600 O/h, DC-13 at 24 V, Outputs 6 A at 360 O/h, DC-13 at 24 V, Outputs In accordance with IEC 60947-5-1, Outputs 3 A at 3600 O/h, AC-15 at 230 V, Outputs |
| Power consumption |
5.16 W
|
| Control voltage 1 - min |
24 V
|
| Control voltage 1 - max |
24 V
|
| Control voltage 2 - min |
24 V
|
| Control voltage 2 - max |
24 V
|
| Control voltage 1 type |
AC/DC
|
| Control voltage 2 type |
AC/DC
|
| Voltage type of supply voltage |
AC/DC
|
| Voltage type of operating voltage |
AC/DC
|
| Rated switch current |
6 A
|
| Supply voltage at AC, 50 Hz - min |
24 V
|
| Supply voltage at AC, 50 Hz - max |
24 V
|
| Supply voltage at AC, 60 Hz - min |
24 V
|
| Supply voltage at AC, 60 Hz - max |
24 V
|
| Supply voltage at DC - min |
24 V
|
| Supply voltage at DC - max |
24 V
|
| Operating voltage at AC, 50 Hz - min |
24 V
|
| Operating voltage at AC, 50 Hz - max |
24 V
|
| Operating voltage at AC, 60 Hz - min |
24 V
|
| Operating voltage at AC, 60 Hz - max |
24 V
|
| Operating voltage at DC - min |
24 V
|
| Operating voltage at DC - max |
24 V
|