Product Name |
Eaton Moeller® series MSC-DE DOL starter
|
Catalog Number |
167820
|
Product Length/Depth |
145 mm
|
Product Height |
272 mm
|
Product Width |
45 mm
|
Product Weight |
1.274 kg
|
Certifications |
CE
CSA-C22.2 No. 14-10 CSA Class No.: 3211-08 VDE 0660 CSA IEC/EN 60947-4-1 UL CSA File No.: 012528 UL Category Control No.: NKJH UL File No.: E123500 UL60947-4-1A |
Type |
Starter with electronic trip unit
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Fitted with: |
Short-circuit release
|
Pollution degree |
3
|
Class |
Adjustable
|
Connection to SmartWire-DT |
No
|
Rated impulse withstand voltage (Uimp) |
6000 V AC
|
Model |
UL Type E starter
|
Altitude |
Max. 2000 m
|
Electrical connection type of main circuit |
Screw connection
|
Voltage type |
DC
|
Mounting method |
DIN rail
|
Current flow times - min |
Note: Going below the minimum current flow time can cause overheating of the load (motor).
For all combinations with an SWD activation, you need not adhere to the minimum current flow times and minimum cut-out periods. 900 (Class 15) AC-4 cycle operation, Main conducting paths 1000 (Class 20) AC-4 cycle operation, Main conducting paths 500 (Class 5) AC-4 cycle operation, Main conducting paths 700 (Class 10) AC-4 cycle operation, Main conducting paths |
Overvoltage category |
III
|
Connection |
Screw terminals
|
Cut-out periods - min |
≤ 500 ms, main conducting paths, AC-4 cycle operation
|
Functions |
Temperature compensated overload protection
|
Overload release current setting - min |
3 A
|
Power consumption (sealing) at DC |
0.86 W
|
Rated conditional short-circuit current (Iq), type 2, 230 V |
0 A
|
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V |
0 A
|
Rated conditional short-circuit current, type 1, 480 Y/277 V |
0 A
|
Rated conditional short-circuit current, type 1, 600 Y/347 V |
0 A
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
12 A
|
Short-circuit current rating (basic rating) |
10 kA, SCCR (UL/CSA)
150 A, max. CB, SCCR (UL/CSA) 200 A, max. Fuse, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 480 V) |
65 kA, CB, SCCR (UL/CSA)
100 kA, Fuse, SCCR (UL/CSA) 100 A, Class J, max. Fuse, SCCR (UL/CSA) 75 A, max. CB, SCCR (UL/CSA) |
Short-circuit current rating (high fault at 600 V) |
100 kA, Fuse, SCCR (UL/CSA)
110 A, Class J/CC, max. Fuse, SCCR (UL/CSA) |
Switching capacity (auxiliary contacts, general use) |
15 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA) |
Switching capacity (auxiliary contacts, pilot duty) |
P300, DC operated (UL/CSA)
A600, AC operated (UL/CSA) |
Rated operational current (Ie) |
16.7 A
|
Rated operational current for specified heat dissipation (In) |
12 A
|
Rated operational voltage |
208 - 600 V AC
|
Short-circuit current rating (type E) |
18 kA, 240 V, SCCR (UL/CSA)
18 kA, 480 Y/277 V, SCCR (UL/CSA) |
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-25 °C
|
Assigned motor power at 200/208 V, 60 Hz, 3-phase |
3 HP
|
Assigned motor power at 230/240 V, 60 Hz, 3-phase |
3 HP
|
Assigned motor power at 460/480 V, 60 Hz, 3-phase |
7.5 HP
|
Equipment heat dissipation, current-dependent Pvid |
4.2 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
1.4 W
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
1
|
Number of command positions |
0
|
Number of pilot lights |
0
|
Overload release current setting - max |
12 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
3 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
7.5 kW
|
Rated power at 460 V, 60 Hz, 3-phase |
5.52 kW
|
Rated power at 575 V, 60 Hz, 3-phase |
0 kW
|
Short-circuit release (Irm) - max |
186 A
|
Static heat dissipation, non-current-dependent Pvs |
0.86 W
|
Coordination class (IEC 60947-4-3) |
Class 2
|
Degree of protection |
IP20
NEMA Other |
Electrical connection type for auxiliary- and control-current circuit |
Screw connection
|
Actuating voltage |
24 V DC
|
Power consumption |
0.9 W
|