照片为代表
Download
Eaton Moeller series NZM - Molded Case Circuit Breaker. Interface module for NZM2 PXR25, connection for communication, zone selectivity, ARMS
Product Name |
Eaton Moeller series NZM electronic accessory
|
Catalog Number |
189832
|
Product Length/Depth |
76 mm
|
Product Height |
65 mm
|
Product Width |
68 mm
|
Product Weight |
0.021 kg
|
Compliances |
IEC
UL/CSA RoHS conform |
Used with |
NZM2(-4)-PX…-TZ
|
Voltage rating |
24 V DC
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Frame |
NZM2
|
Accessory/spare part type |
Communication and measuring function
Interface module Accessory |
Connection type |
Push-in (Logical Zone Selectivity (ZSI) connection)
5-pin plug connector (CAM connection) Cable (Logical Zone Selectivity (ZSI) connection, connection technique) With bolt connection With push in terminal Assembled CAM cable (Supply connection, Digital-input) Pre-wired cable to the Modbus module (internal COM connection) Screw terminal (supply connection, rated control voltage) 10-pin plug connector (internal COM connection) |
Current consumption - max |
100 mA
|
Strip length |
5 mm (supply connection), 6 mm (digital input)
|
Degree of protection |
Installation in the switch
|
Type |
Accessory
Interface module
|
Special features |
For universal connection of optional circuit breaker functions.
Required for communication
The connection types depend on the design of the interface module.
Circuit breaker status detection (I, +, 0) for the electronic trip unit.
The switch's status can be communicated.
24 V DC auxiliary power connection.
Connection for Communications Adapter Module (CAM).
Optional CAM available for various Fieldbus communication systems (Profibus DP, SmartWire-DT, Ethernet-based Fieldbus).
Connection to optional, internal Modbus RTU module.
Connector for Logical Zone Selectivity (ZSI) function.
Mechanical pass-through of the switch's status (I, O) for use by the remote operator.
|
Terminal capacity (stranded cable) |
0.25 mm² - 0.75 mm² (1x) at supply connection (insulated ferrule according to DIN46224 / 4)
0.25 mm² - 0.75 mm² (1x) at supply connection (uninsulated ferrule according to DIN46224 / 1) 0.2 mm² - 0.5 mm² (1x) at digital input of supply connection 0.2 mm² - 1.5 mm² (1x) at supply connection 24 - 16 AWG (1x) at supply connection 0.25 mm² - 0.5 mm² (1x) at logical zone selectivity connection with uninsulated ferrule according to DIN46228 / 1 |
Terminal capacity (solid cable) |
0.2 mm² - 1.5 mm² (1x) at supply connection
0.2 mm² - 0.5 mm² (1x) at logical zone selectivity (ZSI) connection |
Tightening torque |
≤ 0.25 Nm
≥ 0.22 Nm |
Control voltage tolerance |
+/- 20%
|