Eaton Moeller® series EMS2 Reversing starter, 24 V DC, 0,18 - 3 A, Push in terminals, SmartWire-DT slave, Controlled stop, PTB 19 ATEX 3000
Product Name |
Eaton Moeller® series EMS2 Reversing starter
|
Catalog Number |
192386
|
Product Length/Depth |
114.5 mm
|
Product Height |
99 mm
|
Product Width |
22.5 mm
|
Product Weight |
0.297 kg
|
Certifications |
IEC/EN 60947-4-2
UL508 IEC 61508 EN ISO 13849 UL File No.: E338590 UL Category Control No.: NLDX, NLDX7 PTB 19 ATEX 3000 UL 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE marking UL listed Certified by UL for use in Canada UL report applies to both US and Canada |
Type |
Reversing starter (complete device)
|
10.10 Temperature rise |
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
|
10.11 Short-circuit rating |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.12 Electromagnetic compatibility |
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
|
10.13 Mechanical function |
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
|
10.2.2 Corrosion resistance |
Meets the product standard's requirements.
|
10.2.3.1 Verification of thermal stability of enclosures |
Meets the product standard's requirements.
|
10.2.3.2 Verification of resistance of insulating materials to normal heat |
Meets the product standard's requirements.
|
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects |
Meets the product standard's requirements.
|
10.2.4 Resistance to ultra-violet (UV) radiation |
Meets the product standard's requirements.
|
10.2.5 Lifting |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.6 Mechanical impact |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.2.7 Inscriptions |
Meets the product standard's requirements.
|
10.3 Degree of protection of assemblies |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.4 Clearances and creepage distances |
Meets the product standard's requirements.
|
10.5 Protection against electric shock |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.6 Incorporation of switching devices and components |
Does not apply, since the entire switchgear needs to be evaluated.
|
10.7 Internal electrical circuits and connections |
Is the panel builder's responsibility.
|
10.8 Connections for external conductors |
Is the panel builder's responsibility.
|
10.9.2 Power-frequency electric strength |
Is the panel builder's responsibility.
|
10.9.3 Impulse withstand voltage |
Is the panel builder's responsibility.
|
10.9.4 Testing of enclosures made of insulating material |
Is the panel builder's responsibility.
|
Class |
CLASS 10
|
Connection to SmartWire-DT |
Yes
|
Model |
Reversing starter
|
Explosion safety category for dust |
ATEX dust-ex-protection, II (2) D [Ex t] [Ex p]
ATEX dust-ex-protection, II (2) G [Ex e] [Ex d] [Ex px] |
Electrical connection type of main circuit |
Spring clamp connection
|
Voltage type |
DC
|
Mounting position |
Vertical
Motor feeder at bottom |
Mounting method |
Top-hat rail fixing (according to IEC/EN 60715, 35 mm)
Rail mounting possible |
Connection |
Push in terminals
|
Functions |
For connecting to SmartWire-DT for expanded diagnostics
Controlled stop Reversing start Motor protection Temperature compensated overload protection DOL starting Automatic reset Display of Device Type Display of Enable signal Manual reset Display of Motor current in % Display of Operating direction feedback Operating the motor starter Display of Operational readiness Display of Overload prewarning Display of Set short-circuit release value Display of Thermal motor image in % Display of Trip indications (overload, phase failure, etc.) |
Terminal capacity |
0.2 - 2.5 mm², Main cables, Push-in terminals
|
Terminal capacity (AWG) |
24 - 14, Push-in terminals
|
Overload release current setting - min |
0.18 A
|
Power consumption (sealing) at DC |
2.5 W
|
Rated actuating current (Ic) |
5 mA
|
Rated conditional short-circuit current (Iq), type 2, 230 V |
0 A
|
Rated conditional short-circuit current (Iq), type 2, 380 V, 400 V, 415 V |
0 A
|
Rated conditional short-circuit current, type 1, 480 Y/277 V |
0 A
|
Rated conditional short-circuit current, type 1, 600 Y/347 V |
0 A
|
Rated control supply current Is |
60 mA
|
Rated control supply voltage (Us) at AC, 50 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 50 Hz - min |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - max |
0 V
|
Rated control supply voltage (Us) at AC, 60 Hz - min |
0 V
|
Rated control supply voltage (Us) at DC - max |
24 V
|
Rated control supply voltage (Us) at DC - min |
24 V
|
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V |
3 A
|
Radio interference class |
EN 55011
Class A (EN 61000-6-3, emitted interference, radiated) |
Residual ripple |
≤ 5 % (input voltage)
|
Rated control supply voltage |
19.2 - 30 V DC
|
Protocol |
Other bus systems
|
Inrush current |
120 mA (draw)
|
Rated control voltage (Uc) |
24 V (Actuating circuit ON, L, R)
|
Rated operational current (Ie) |
3 A
|
Rated operational current (Ie) at AC-51 |
3 A
|
Rated operational current (Ie) at AC-53A - max |
3 A
|
Rated operational current for specified heat dissipation (In) |
3 A
|
Rated operational voltage |
42 - 550 V
500 V AC |
Safety parameter (EN ISO 13849-1) |
3, Category
PL e, Performance level 60 (safe switch off) / 82 (motor protection) years; MTTFD |
Safety parameter (IEC 62061) |
Opening delay [ms]: 200 (safe switch off) / Class 10 (motor protection)
99 % (safe switch off) / 98 % (motor protection), DC |
Switching level |
-3 - 9.6 V DC, Switching level "Low", Actuating circuit (ON, L, R)
19.2 - 30 V DC, Switching level "High", Actuating circuit (ON, L, R) < 5 V DC, Switching level "confirm Off", Actuating circuit (ON, L, R) |
Ambient operating temperature - max |
55 °C
|
Ambient operating temperature - min |
-5 °C
|
Ambient storage temperature - max |
80 °C
|
Ambient storage temperature - min |
40 °C
|
Equipment heat dissipation, current-dependent Pvid |
2.5 W
|
Heat dissipation capacity Pdiss |
0 W
|
Heat dissipation per pole, current-dependent Pvid |
0 W
|
Number of auxiliary contacts (normally closed contacts) |
0
|
Number of auxiliary contacts (normally open contacts) |
0
|
Number of command positions |
0
|
Number of pilot lights |
0
|
Overload release current setting - max |
3 A
|
Rated operational power at AC-3, 220/230 V, 50 Hz |
0.55 kW
|
Rated operational power at AC-3, 380/400 V, 50 Hz |
1.1 kW
|
Rated operational power at AC-53A, 380/400 V, 50 Hz |
1.1 kW
|
Rated power at 460 V, 60 Hz, 3-phase |
0 kW
|
Rated power at 575 V, 60 Hz, 3-phase |
0 kW
|
Static heat dissipation, non-current-dependent Pvs |
2 W
|
Heat dissipation details |
If necessary, Allow for derating
|
Product category |
Electronic motor starter
|
Coordination class (IEC 60947-4-3) |
Class 1
|
Degree of protection |
IP20
NEMA Other |
Electrical connection type for auxiliary- and control-current circuit |
Spring clamp connection
|
Actuating voltage |
24 V DC
|
Power consumption |
2.5 W
|