Eaton Moeller® series DILK Contactor for capacitors, with series resistors, 20 kVAr, *V 50 Hz
| Product Name | 
                                                Eaton Moeller® series DILK capacity contactor
                                             | 
| Catalog Number | 
                                                294019
                                             | 
| Product Length/Depth | 
                                                138 mm
                                             | 
| Product Height | 
                                                135 mm
                                             | 
| Product Width | 
                                                45 mm
                                             | 
| Product Weight | 
                                                0.51 kg
                                             | 
| Certifications | 
                                                UL File No.: E29096  CE CSA CSA-C22.2 No. 60947-4-1-14 UL UL Category Control No.: NLDX CSA Class No.: 3211-04 IEC/EN 60947 IEC/EN 60947-4-1 CSA File No.: 012528 UL 60947-4-1 | 
| 10.10 Temperature rise | 
                                                The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
                                             | 
| 10.11 Short-circuit rating | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.12 Electromagnetic compatibility | 
                                                Is the panel builder's responsibility. The specifications for the switchgear must be observed.
                                             | 
| 10.13 Mechanical function | 
                                                The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
                                             | 
| 10.2.2 Corrosion resistance | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.1 Verification of thermal stability of enclosures | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.2 Verification of resistance of insulating materials to normal heat | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.4 Resistance to ultra-violet (UV) radiation | 
                                                Meets the product standard's requirements.
                                             | 
| 10.2.5 Lifting | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.6 Mechanical impact | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.2.7 Inscriptions | 
                                                Meets the product standard's requirements.
                                             | 
| 10.3 Degree of protection of assemblies | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.4 Clearances and creepage distances | 
                                                Meets the product standard's requirements.
                                             | 
| 10.5 Protection against electric shock | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.6 Incorporation of switching devices and components | 
                                                Does not apply, since the entire switchgear needs to be evaluated.
                                             | 
| 10.7 Internal electrical circuits and connections | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.8 Connections for external conductors | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.2 Power-frequency electric strength | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.3 Impulse withstand voltage | 
                                                Is the panel builder's responsibility.
                                             | 
| 10.9.4 Testing of enclosures made of insulating material | 
                                                Is the panel builder's responsibility.
                                             | 
| Fitted with: | 
                                                Series resistors
                                             | 
| Operating frequency | 
                                                120 Operations/h
                                             | 
| Ambient operating temperature - max | 
                                                60 °C
                                             | 
| Ambient operating temperature - min | 
                                                -25 °C
                                             | 
| Ambient operating temperature (enclosed) - max | 
                                                40 °C
                                             | 
| Ambient operating temperature (enclosed) - min | 
                                                25 °C
                                             | 
| Equipment heat dissipation, current-dependent Pvid | 
                                                5.4 W
                                             | 
| Heat dissipation capacity Pdiss | 
                                                0 W
                                             | 
| Heat dissipation per pole, current-dependent Pvid | 
                                                1.8 W
                                             | 
| Number of auxiliary contacts (normally closed contacts) | 
                                                1
                                             | 
| Number of auxiliary contacts (normally open contacts) | 
                                                1
                                             | 
| Number of contacts (normally closed) as main contact | 
                                                0
                                             | 
| Number of main contacts (normally open contact) | 
                                                3
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - max | 
                                                600 V
                                             | 
| Rated control supply voltage (Us) at AC, 50 Hz - min | 
                                                24 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - max | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at AC, 60 Hz - min | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at DC - max | 
                                                0 V
                                             | 
| Rated control supply voltage (Us) at DC - min | 
                                                0 V
                                             | 
| Rated operational current for specified heat dissipation (In) | 
                                                29 A
                                             | 
| Rated operational power at AC-6B, 220/230 V, 50 Hz | 
                                                11 kW
                                             | 
| Rated operational power at AC-6B, 380/400 V, 50 Hz | 
                                                20 kW
                                             | 
| Rated operational power at AC-6B, 525 V, 50 Hz | 
                                                25 kW
                                             | 
| Rated operational power at AC-6B, 690 V, 50 Hz | 
                                                33.3 kW
                                             | 
| Static heat dissipation, non-current-dependent Pvs | 
                                                2.1 W
                                             | 
| Switching time (AC operated, make contacts, closing delay) - max | 
                                                22 ms
                                             | 
| Switching time (AC operated, make contacts, closing delay) - min | 
                                                16 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - max | 
                                                14 ms
                                             | 
| Switching time (AC operated, make contacts, opening delay) - min | 
                                                8 ms
                                             | 
| Application | 
                                                Contactors for power factor correction
                                             | 
| Product category | 
                                                DILK Contactors for capacitors
                                             | 
| Protection | 
                                                Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
                                             | 
| Number of auxiliary contacts (change-over contacts) | 
                                                0
                                             | 
| Rated switch current | 
                                                29 A
                                             | 
| Operating voltage at AC, 50 Hz - min | 
                                                230 V
                                             | 
| Operating voltage at AC, 50 Hz - max | 
                                                690 V
                                             | 
| Operating voltage at AC, 60 Hz - min | 
                                                230 V
                                             | 
| Operating voltage at AC, 60 Hz - max | 
                                                690 V
                                             | 
| Rated blind power at 400 V, 60 Hz | 
                                                20 kWAR
                                             | 
| Arcing time | 
                                                10 ms
                                             | 
| Electrical connection type of main circuit | 
                                                Screw connection
                                             | 
| Voltage type | 
                                                AC
                                             | 
| Degree of protection | 
                                                IP00
                                             | 
| Drop-out voltage | 
                                                AC operated: 0.6 - 0.3 x UC, AC operated
                                             | 
| Duty factor | 
                                                100 %
                                             | 
| Emitted interference | 
                                                According to EN 60947-1
                                             | 
| Interference immunity | 
                                                According to EN 60947-1
                                             | 
| Lifespan, electrical | 
                                                150,000 Operations
                                             | 
| Making capacity without damping (I-peak value) | 
                                                180 x Ie
                                             | 
| Pick-up voltage | 
                                                0.8 - 1.1 V AC x Uc
                                             | 
| Power consumption, pick-up, 50 Hz | 
                                                58 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
                                             | 
| Power consumption, pick-up, 60 Hz | 
                                                71 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
                                             | 
| Power consumption, sealing, 50 Hz | 
                                                7.6 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz  2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz | 
| Power consumption, sealing, 60 Hz | 
                                                9.3 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz  2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz | 
| Rated blind power | 
                                                20 kvar
                                             | 
| Rated operational current (Ie) | 
                                                29 A at 525 V (three-phase capacitors, open)  26 A at 525 V (three-phase capacitors, enclosed) 29 A at 400 V (three-phase capacitors, open) 29 A at 230 V (three-phase capacitors, open) 29 A at 690 V (three-phase capacitors, open) 26 A at 230 V (three-phase capacitors, enclosed) 26 A at 400 V (three-phase capacitors, enclosed) 26 A at 690 V (three-phase capacitors, enclosed) | 
| Special purpose rating of capacitor switching | 
                                                12 kVar, 240 V 60 Hz 3phase, (UL/CSA)  28 A, 240 V 60 Hz 3phase, (UL/CSA) 28 A, 480 V 60 Hz 3phase, (UL/CSA) 28 A, 600 V 60 Hz 3phase, (UL/CSA) 20 kVar, 480 V 60 Hz 3phase, (UL/CSA) 30 kVar, 600 V 60 Hz 3phase, (UL/CSA) | 
| Terminal capacity (stranded) | 
                                                1 x 16 mm², Main cables
                                             | 
| Switching capacity (auxiliary contacts, general use) | 
                                                1 A, 250 V DC, (UL/CSA)  10 A, 600 V AC, (UL/CSA) | 
| Switching capacity (auxiliary contacts, pilot duty) | 
                                                A600, AC operated (UL/CSA)  P300, DC operated (UL/CSA) | 
| Terminal capacity (flexible with ferrule) | 
                                                1 x (0.75 - 16) mm², Main cables
                                             | 
| Terminal capacity (solid) | 
                                                1 x (0.75 - 16) mm², Main cables
                                             | 
| Terminal capacity (solid/stranded AWG) | 
                                                18 - 6, Main cables
                                             |