| Product Name |
Eaton 9PX UPS
|
| Catalog Number |
9PX6K-L
|
| UPC |
786689772598
|
| Product Length/Depth |
28.43 in
|
| Product Height |
5.12 in
|
| Product Width |
17.32 in
|
| Product Weight |
80.25 lb
|
| Compliances |
FCC part 15 class A
CE cULus Listed |
| Certifications |
RoHS
EN 62040-2:2006 IEC 62040-2 NOM ICC-ES AC156 OSHPD Seismic certified |
| Topology |
Online/Double-conversion
|
| Rack size |
3U
|
| Color |
Black/silver
|
| VA rating |
6000 VA
|
| Wattage |
5400 W
|
| Rack mounting kit |
Yes
|
| Package contents |
|
| Surge protection |
Yes
|
| Internal bypass |
Yes
|
| Primary frequency - max |
60 Hz
|
| Primary frequency - min |
50 Hz
|
| Current Crest Ratio |
3:1
|
| Recharge Time to 90% Capacity |
3 hour
|
| Voltage Regulation |
< 1%
|
| Input connection |
L6-30P
|
| Input cord length |
10 ft
|
| Input nominal voltage |
208V default (200/208/220/230/240V)
|
| Nominal frequency |
50-60 Hz
|
| Input frequency range |
60 Hz: 50–70 Hz, 50 Hz: 40–60 Hz
|
| Input power factor |
.99
|
| Receptacle |
Hardwire, (2) L6-30R, (2) L6-20R
|
| Number of Outputs L6-20R |
2
|
| Number of Outputs L6-30R |
2
|
| Number of outputs hardwired |
1
|
| Output waveform |
True sine wave
|
| Voltage |
208 V
|
| Output nominal voltage |
208V default (200/208/220/230/240V)
|
| Runtime graph |
|
| Battery management |
Lithium-ion Battery Management System (BMS)
|
| Battery replacement |
Hot-swappable internal batteries and extended battery modules (EBMs). Replacement battery part # EBP-1801-L (qty 1 per UPS).
|
| Battery type |
Lithium-ion
|
| Extended battery capability |
Add up to 4 EBMs, part # 9PXEBM192RT-L
|
| Standard factory warranty |
5 year limited
|
| Runtime at half load |
17.4 min
|
| Battery Chemistry |
Lithium Iron Phosphate (LiFePo4)
|
| Ethernet interface |
Yes
|
| Includes network card |
Yes
|
| Software compatibility |
Intelligent Power Software Suite
|
| User interface |
Graphical display, 5-button programmable menu
|
| Altitude |
<1000m for nominal power, 10% power degrading every 1000m (up to 3000m)
|
| BTU Rating |
Online: 1233 BTU/hr, Battery: 1699 BTU/hr (100% load)
|
| Noise level |
<45 dB at 1 meter
|
| Relative humidity |
0-95% non-condensing
|
| Temperature range |
0° to 40°C (32° to 104°F)
|
| Mounting Method |
Rackmount
Tower |
| Protocol |
SNMP
|
| Product Highlights |
Keeps equipment running during outages to allow time for file saves and safe shutdown
Improved lithium-ion batteries have lifespan up to 10 years - set it and forget it! Included NETWORK-M3 Gigabit network card enables full remote access and control Interactive LCD interface keeps you updated on critical load information in real time Optional extended battery modules allow expanded runtime to keep equipment powered |
| Input voltage - max |
240 V
|
| Input voltage - min |
200 V
|
| Output voltage - max |
240 V
|
| Output voltage - min |
200 V
|
| Efficiency at max. load |
93%
|
| Input voltage range |
200-240V
|
| Max number of battery packs |
4
|
| Output frequency |
50/60 Hz
|
| Output power factor |
.9
|
| Output voltage range |
±1% normal mode
|
| Runtime at full load |
8.7 minutes
|
| Communication interface |
RS-232
USB |
| Replacement Battery Cartridge |
EBP-1801-L
|
| Output Capacity Details |
5200VA / 4600W at 200V Output
5400VA / 4800W at 208V Output 5700VA / 5100W at 220V Output 6000VA / 5300W at 230V Output 6000VA / 5400W at 240V Output |